• Title/Summary/Keyword: Load modulation

Search Result 326, Processing Time 0.027 seconds

A Pulse Width Modulation(CPWM) Technique with Chaos Phenomenon (혼돈 특성을 갖는 펄스폭 변조(CPWM)방식)

  • Kim, J.N.;Kim, J.H.;Jung, Y.G.;Lim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.270-274
    • /
    • 2006
  • This paper proposes a Chaos Pulse Width Modulation(CPWM) technique. For generating the chaotic numbers by chaos phenomenon, chaos area $\lambda$=0.99 in bifurcation tree of the proposed double tent mapping is used. A micro-controller is used for the generation of chaos numbers and triangular carrier with chaotic frequency is obtained through the process of frequency modulation according to the generated chaos numbers. The experiments are executed with the 1.5kw induction motor coupled with a 2.5A load. The experimental results show that the voltage / current spectra are spread to a chaotic range, and the switching noise of motor is reduced by the proposed method compared to the fixed frequency PWM method.

  • PDF

Selection of pulse number and modulation index for minimum speed ripple in trapezoidal CSI-PWM (Trapezoidal PWM 전류원 인버터에서 최소 Speed Ripple을 위한 펄스 수 및 변조도의 결정)

  • Kwon, Woo-Hyeon;Goo, Bon-Ho;Lee, Chi-Hwan;Lee, Chang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.127-129
    • /
    • 1988
  • Square-wave current source inverter drives suffer from torque pulsation and speed variation at low speed. Attempts to minimize these problems, CSI PWM strategies have been reported. It is shown that these PWM strategies are based on unnecessarily restrictive modulation laws. In this paper, trapezoidal PWM strategy for CSI is investigated theoratically by double fourier series and we proposed Harmonic Speed ripple Factor(HSF) that is independent of motor parameters and load conditions. Speed ripple are considered in T-PWM and square wave inverter by HSF. We obtain modulation index(M) and carrier ratio (CR) for minimum speed ripple.

  • PDF

A Study on The Resonant Frequency Following Control of Resonant Inverters (공진형 인버터의 공진 주파수 추종 제어에 관한 연구)

  • Kim, Nam-Jeung;Yo, Wan-Sik;Cho, Kyu-Min;In, Chi-Gak
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1177-1181
    • /
    • 2000
  • Usually, in many applications. high frequency resonant inverters are used, and the PAM(Pulse Amplitude Modulation), PFM(Pulse Frequency Modulation) or PWM(Pulse Width Modulation) techniques are used to control the output power of resonant inverters. And the resonant inverters have to control the output frequency for the reliable operation under the variable load conditions. In this paper, a new switching scheme is proposed as a resonant frequency following control of resonant inverters. With the proposed method. it can be obtained that optimum resonant frequency and unity output displacement factor under the variable resonant frequency adaptively. The detail algorithm of the proposed switching scheme and its characteristics are discussed. And the veridity of the proposed method is confirmed with the experimental results.

  • PDF

Voltage Source Inverter Drive Using Error-compensated Pulse Width Modulation

  • Chen, Keng-Yuan;Hu, Jwu-Sheng;Lin, Jau-Nan
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.388-397
    • /
    • 2016
  • An error-compensated pulse width modulator (ECPWM) is proposed to improve the baseband harmonic performance and the switching loss of voltage source inverters (VSIs). Selecting between harmonic distortion and switching loss is a design tradeoff in the conventional space vector pulse width modulation. In this work, an accumulated difference in produced and desired phase voltages is considered to adjust the reference signal. This mechanism can compensate for the voltage error in the previous carrier period. With error compensation every half-carrier period, the proposed ECPWM allows one-half reduction in carrier frequency without scarifying baseband harmonic distortion. The proposed modulator is applied to a three-phase VSI with R-L load and a motor-speed-control system for experiments. The measured efficiency and operating temperature of switches confirm the effectiveness of the proposed scheme.

Research of the adaptive control on modulation factor for PSR fly-back PSM converter

  • Tian, Lei;Li, Qinqin;Wang, Weiheng
    • ETRI Journal
    • /
    • v.41 no.1
    • /
    • pp.124-132
    • /
    • 2019
  • The energy balance (EB) model of a primary side regulation (PSR) fly-back converter in the discontinuous conduction mode (DCM) is discussed in this paper. Based on this EB model, the stability of a PSR fly-back converter in the pulse skipping mode (PSM) is analyzed, and a self-adapting modulation factor control strategy is proposed. Theoretical analysis and simulation results show that by saving an optocoupler and correlative circuits, which are necessary in traditional PSM fly-back converters, the modulation factor tolerance controlled by this method is 1.26% on average, corresponding to the ideal value. Compared with traditional fly-back PSM controllers, the power saved in the sampler/comparator modules is 87% on average for a load range of $1{\Omega}$ to $1k{\Omega}$.

Control and Operating Characteristics of Three-Phase Matrix Converter with Unity Power Factor by Direct Duty-Ratio Modulation Method (단위 역률을 갖는 직접 시비율 변조방식 3상 매트릭스 컨버터의 제어 및 동작 특성)

  • Li, Yulong;Choi, Nam-Sup;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.142-149
    • /
    • 2009
  • This paper investigates operating characteristics of three-phase matrix converter with unity input power factor by direct duty-ratio pulse-width modulation in the case of balanced and unbalanced load. It can be found from the system analysis that (1) The control algorithm for unity power factor is not related to the variables of load sides but the input voltages, (2) With the balanced three-phase load except for the pure reactive load, the unity input power factor can be achieved, (3) In the case of the unbalanced linear load, the equivalent input characteristics of the matrix converter can be seen like the nonlinear resister, (4) When the input frequency and the output frequency have the specific relationship, each input phases have the same sharing of the average power. The feasibility and validity of the analysis were verified by simulation and experimental results.

A Vibration-based Fault Diagnostics Technique for the Planetary Gearbox of Wind Turbines Considering Characteristics of Vibration Modulation (풍력발전기 유성기어박스의 진동 변조 특성을 고려한 진동기반 고장 진단 기법 고찰)

  • Ha, Jong M.;Park, Jungho;Oh, Hyunsoek;Youn, Byeng D.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.7
    • /
    • pp.665-671
    • /
    • 2015
  • The performance of fault diagnostics for a planetary gearbox depends on vibration modulation characteristics, which can vary with manufacturing & assembly tolerance, and load condition. In this paper, a fault diagnostics technique that considers vibration modulation characteristics is proposed for the effective fault detection of planetary gearboxes in wind turbines. For identifying the vibration modulation characteristics in practice, re-sampled vibration signals are processed with narrow band-pass filters. Thereafter, the optimal position of the vibration extraction window is identified for effective detection of faulty signals under the varying vibration modulation characteristics. The proposed diagnostics technique makes it possible to perform robust diagnostics of the planetary gearbox with regard to the changeable vibration modulation effect. For demonstrating the proposed fault diagnostics technique, a 2-kW WT testbed is designed with two DC motors and gearboxes. A faulty gear with partial tooth breakage is machined and assembled into the gearbox.

Half Load-Cycle Worked Dual Input Single Output DC/AC Inverter

  • Chen, Rong;Zhang, Jia-Sheng
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1217-1223
    • /
    • 2014
  • A novel half load-cycle worked dual input single output (DISO) DC/AC inverter is presented. The basic circuit consists of a dual buck regulator, which works in continuous current mode. The working principle of DISO DC/AC inverter has been used. The control method applied for half load-cycle worked DISO DC/AC inverter has been studied. The control effects of the open-loop proportional control and closed-loop proportional-integral control are compared by using PSIM software. The parameters are adopted in the realistic simulation and experiment test. Moreover, the waveforms, such as voltage of modulation reference signal and output voltage, were given. The simulation and experiment results proved that the half load-cycle worked DISO DC/AC inverter could achieve good performance, gain a line frequency of 50 Hz, and verify the correctness of theoretical analysis.

Nonlinear Control of Three-phase Split-Capacitor Inverters under Unbalanced and Nonlinear Load Conditions

  • Nguyen, Qui Tu Vo;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.52-53
    • /
    • 2012
  • This paper presents a new control scheme for a three-phase split DC-link capacitor inverter as an AC power supplies. The proposed control method can maintain the balanced sinusoidal output voltage under unbalanced and nonlinear load conditions. The validity of the control method has been verified by simulation results.

  • PDF

EFFICIENT OZONIZER USING VOLTAGE-SOURCE LOAD RESONANT INVERTER WITH PDM AND PWM CONTROL IMPLEMENTATION

  • Kohishi, Yoshihiro;Wang, Shengpei;Shirakawa, Shinya;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1024-1029
    • /
    • 1998
  • In this paper, the voltage-fed series compensated inductor type load-resonant high-frequency inverter is originally presented for driving a newly-developed silent discharge ozone generating tube. The effective power regulation scheme of this ozonizer is proposed, which is based on PDM (Pulse Density Modulation) related PWM strategy due to DSP implementation. The effectiveness of this inverter type ozonizer is proved in simulation and experiment.

  • PDF