• 제목/요약/키워드: Load Variation

검색결과 2,083건 처리시간 0.041초

전류공유버스를 이용한 병렬 인버터 순시 제어기 설계 (Instantaneous Current Control for Parallel Inverter with a Current Share Bus)

  • 이창석;김시경
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.90-94
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employes active and reactive power control or frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employes a instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Futhermore, the proposed control scheme is verified through the simulation in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

A Current Sharing Circuit for the Parallel Inverter

  • Lee, Chang-Seok;Kim, Si-Kyung
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.176-181
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employs active and reactive power control of frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel-connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employees an instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Furthermore, the proposed control scheme is verified through the experiment in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

연산시간지연을 고려한 UPS 인버터용 2차 데드비트 전류 제어기의 강인 제어 (Robust control of End order deadbeat current controller considering calculation time delay for UPS inverter)

  • 김병진;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1056-1058
    • /
    • 2000
  • Deadbeat technique has been proposed as a digital controller for an UPS inverter to achieve the fast response to a load variation and to conserve a very low THD under a nonlinear load condition. This scheme contains a fatal drawback, sensitivity against parameter variation and calculation time delay. This paper proposes a second order deadbeat current controller, which fundamentally solves the calculation time delay problem and certainly guarantees the robustness of the parameter's variation. This is shown theoretically and practically through simulation and experiment.

  • PDF

Simulink에서 영구자석 동기형 풍력발전시스템의 전압변동에 대한 시뮬레이션 (Simulation for Voltage Variation of a Permanent Magnetic Synchronous Generator Wind Turbine Systems on Simulink)

  • 안해준;김현구;김홍우;장길수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.184.2-184.2
    • /
    • 2010
  • This study performs modelling and simulation of permanent magnetic synchronous generator wind turbine by using Matlab & Simulink. In simulation, change of wind velocity, change of load, and voltage decrease of infinite bus are performed. Through such simulation, different with wiring system that there is only existing load, this study can confirm problems and voltage changing characteristics, which can occur in distributed electric power that load and electric power is mixed and operated, especially, in interconnecting with wind power generation.

  • PDF

마찰시험기의 시스템 동적변수 변화에 따른 미끄럼마찰 특성 (Sliding Frictional Characteristics with the Change of Dynamic Parameters in the Friction Measurement)

  • 공호성;윤의성;권오관;오재응
    • Tribology and Lubricants
    • /
    • 제11권2호
    • /
    • pp.44-55
    • /
    • 1995
  • Frictional characteristics with the change of dynamic parameters, such as stiffness, inertia and damping, in the friction measurement at dry sliding surfaces were experimentally and theoretically investigated throughout the study. Dynamic frictional force and the variation in the normal load were mainly measured at the various conditions of system dynamic parameters with which stiffness in the normal direction, loading mechanisms and test materials were varied. For the normal load, mechanisms using both a dead weight and a pneumatic cylinder were applied, which resulted in change of the inertia and damping of the test rig. Test materials were steel, rosin and PTFE, which have different types of intrinsic frictional characteristics. Test results showed that frictional characteristics under different dynamic parameters could be different even though the operating variables were the same and also they could result in the variation in the normal load, which could consequently affect the wear mechanism.

태양광 발전이 연계된 DC 마이크로 그리드의 시뮬레이션 (Simulation of DC Microgrid with PV Generation)

  • 박철원
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.267-273
    • /
    • 2017
  • In recent years, there is an increasing demand for DC microgrid because the digital load due to DC increases and the efficiency of the distribution system increases due to loss of conversion losses and conversion stages due to reactive power compared to AC distribution. Currently, with the support of the KEPRI, the development of an electronic large-capacity circuit breaker for DC distribution protection, which has been underway since 2016, is proceeding. In this paper, as a part of this project, we modeled the DC microgrid connected with PV using PSCAD. The converter station, AC/DC converter control, PV and MPPT controller are designed. In order to evaluate the performance of the modeled DC microgrid, it is examined whether the voltage is adjusted according to the load variation.

Cycle-to-Cycle Fluctuations in a Spark Ignition Engine at Low Speed and Load

  • Han, Sung Bin;Hwang, Sung Il
    • 에너지공학
    • /
    • 제22권2호
    • /
    • pp.205-210
    • /
    • 2013
  • Cycle-to-cycle variation has long been recognized as limiting the range of operating conditions of spark ignition engines, in particular, under lean and highly diluted operation conditions. At a part load, some of the cycles tend to knock, while others may have incomplete combustion by the time the exhaust valve opens. An experimental study has been performed in order to evaluate the relative contribution of several relevant parameters on the cyclic variability in spark ignition engines. In general, the stability of engine operation is improved with fuel injector according to the optimal injection timing, but the stability of engine operation at idle is not improved compared with a practical gasoline engine. In this study, we investigated the relationship of the effect of operating conditions for the stability at low speed and load.

HEV용 중대형 2차전지 충전기 설계 및 해석 (Design and Analysis of Large Capacity Lithium Polymer Battery Charger for Hybrid Electrical Vehicle)

  • 오동섭;오성업;성세진;최재동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.87-91
    • /
    • 2004
  • In this paper, the paralleled forward converter, that is generally used as the power supply for the low voltage, high current load, is described. The proposed forward converter for battery charging could be provided the power without failure not only in steady state but also in the transient period by the step load variation or the unexpected faults among the converter modules. Each converter nodule designed is operated alone with the self closed controller for the elevation of stability, performance, reliability, and maintainability. The frequency response of the designed converter module is analyzed, and the stability is confirmed in analytic method. And the experiments of the paralleled battery charger are carried out in steady state, in the step load variation.

  • PDF

Al 원형관의 2축압축 변형특성에 관한 연구 (Biaxial Compressive Deformation Characteristics of Round Aluminum Pipe)

  • 유종근;김기주;원시태
    • 소성∙가공
    • /
    • 제21권2호
    • /
    • pp.89-95
    • /
    • 2012
  • To examine the deformation characteristics of round aluminum pipe under biaxial compression, a horizontal biaxial compression die was fabricated. The change of material properties, punch load and deformation behavior were monitored in experiments using various compressive deformation rates in the range of 1mm/min.~400mm/min. The tensile and compressive strains were estimated from Vickers microhardness results. The punch load and deformation characteristic of the round aluminum pipes were found to change greatly at a deformation rate of about 200mm/min. The punch load decreased with increasing compressive deformation rate. Results of numerical simulation using Deform-2D were in good agreement with experimental results, and the measured hardness variation with the strain variation was predicted well by the simulation.

Robust Speed Control of PMSM with Fuzzy Gain Scheduling

  • Won, Tae-Hyun;Kim, Mun-Soo;Park, Han-Woong;Lee, Man-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.111.1-111
    • /
    • 2001
  • In this paper, a robust speed control is proposed for Permanent Magnet Synchronous Motor system. PMSM without reduction gear has been widely used in high performance application such as robots and machine tools. It is well known that the control performance of the PMSM is very sensitive to load disturbance and system parameter variation. The idea of the proposed speed controller based on combination of sliding mode control with fuzzy gain scheduling. The sliding mode controller leads to fast system dynamics of slight sensitivity to the load disturbance and system parameter variations, the fuzzy gain scheduling mechanism reduces the chattering phenomenon. The simulation results have proved that the proposed control scheme provides a robust control performance under load disturbance and system parameter variation.

  • PDF