• 제목/요약/키워드: Load Losses

검색결과 361건 처리시간 0.027초

Modeling and Control of Integrated STATCOM-SMES System to Improve Power System Oscillations Damping

  • Molina, Marcelo G.;Mercado, Pedro E.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.528-537
    • /
    • 2008
  • Primary frequency control(PFC) has the ability to regulate short period random variations of frequency during normal operation conditions and also to respond rapidly to emergencies. However, during the past decade, numerous significant sized blackouts occurred worldwide that resulted in serious economic losses. Therefore, the conclusion has been reached that the ability of the current PFC to meet an emergency is poor, and security of power systems should be improved. An alternative to enhance the PFC and thus security is to store excessive amounts of energy during off-peak load periods in efficient energy storage systems for substituting the primary control reserve. In this sense, superconducting magnetic energy storage(SMES) in combination with a static synchronous compensator(STATCOM) is capable of supplying power systems with both active and reactive powers simultaneously and very rapidly, and thus is able to enhance the security dramatically. In this paper, a new concept of PFC based on incorporating a STATCOM-SMES is presented. A complete detailed model is proposed and a new control scheme is designed, comprising an enhanced frequency control scheme, and a fully decoupled current control strategy in d-q coordinates with a novel controller to prevent dc bus capacitors voltage drift/imbalance. The performance of the proposed control schemes is validated through digital simulation carried out using MATLAB/Simulink.

An Improved Mean-Variance Optimization for Nonconvex Economic Dispatch Problems

  • Kim, Min Jeong;Song, Hyoung-Yong;Park, Jong-Bae;Roh, Jae-Hyung;Lee, Sang Un;Son, Sung-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.80-89
    • /
    • 2013
  • This paper presents an efficient approach for solving economic dispatch (ED) problems with nonconvex cost functions using a 'Mean-Variance Optimization (MVO)' algorithm with Kuhn-Tucker condition and swap process. The aim of the ED problem, one of the most important activities in power system operation and planning, is to determine the optimal combination of power outputs of all generating units so as to meet the required load demand at minimum operating cost while satisfying system equality and inequality constraints. This paper applies Kuhn-Tucker condition and swap process to a MVO algorithm to improve a global minimum searching capability. The proposed MVO is applied to three different nonconvex ED problems with valve-point effects, prohibited operating zones, transmission network losses, and multi-fuels with valve-point effects. Additionally, it is applied to the large-scale power system of Korea. The results are compared with those of the state-of-the-art methods as well.

Cyclic testing of innovative two-level control system: Knee brace & vertical link in series in chevron braced steel frames

  • Rousta, Ali Mohammad;Zahrai, Seyed Mehdi
    • Structural Engineering and Mechanics
    • /
    • 제64권3호
    • /
    • pp.301-310
    • /
    • 2017
  • For further development of passive control systems to dissipate larger seismic energy and prevent the structures from earthquake losses, this paper proposes an innovative two-level control system to improve behavior of chevron braced steel frames. Combining two Knee Braces, KB, and a Vertical Link Beam, VLB, in a chevron braced frame, this system can reliably sustain main shock and aftershocks in steel structures. The performance of this two-level system is examined through a finite element analysis and quasi-static cyclic loading test. The cyclic performances of VLB and KBs alone in chevron braced frames are compared with that of the presented two-level control system. The results show appropriate performance of the proposed system in terms of ductility and energy dissipation in two different excitation levels. The maximum load capacity of the presented system is about 30% and 17% higher than those of the chevron braced frames with KB and VLB alone, respectively. In addition, the maximum energy dissipation of the proposed system is about 78% and 150% higher than those of chevron braced frames with VLB and KB respectively under two separate levels of lateral forces caused by different probable seismic excitations. Finally, high performance under different earthquake levels with competitive cost and quick installation work for the control system can be found as main advantages of the presented system.

New Multi-Output LLC Resonant Converter for High Efficiency and Low Cost PDP Power Module

  • 김정은;문건우;이준영;오관일;권중열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.71-74
    • /
    • 2006
  • A new multi-output LLC resonant converter is proposed for high efficiency and low cost plasma display panel (PDP) power module. In the proposed converter, zero-voltage (ZV) turn-on of the primary MOSFETs and zero-voltage (ZC) turn-on and turn-off of the secondary diodes are guaranteed in the overall input voltage and output load ranges. In addition, the primary MOSFETs and the secondary diodes have the low voltage stresses clamped to input and the output voltages, respectively. Therefore, the proposed converter shows the high efficiency due to the minimized switching and conduction losses. Moreover, by employing the transformer with multiple secondary windings, the proposed converter can have multiple outputs, which show the great crossregulation characteristics. Therefore, the proposed converter is suitable for high efficiency and low cost PDP power module.

  • PDF

Three-Phase Soft Switching Sinewave Inverter with Bridge Power Module Package Configurated Auxiliary Resonant AC Link Snubber

  • Iyomori Hisashi;Nagai Shin-ichiro;Shiraishi Kazuhiro;Ahmed Tarek;Eiji Hiraki;Mutsuo Nakaoka
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.507-510
    • /
    • 2003
  • This paper presents a novel prototype of tile three-phase bridge power block module type a auxiliary resonant AC link snubber circuit, which is effectively used for the three-phase voltage source type sinewave soft switching PWM inverter using IGBTs. Its operating principle Is described for current source load model, along with its practical design approach based on the simulation data. The performance evaluation of the three-phase voltage source type snewave soft switching PWM inverter incorporating a single three-phase bridge mo여le of active auxiliary resonant AC link snubber treated here Is illustrated, which is concerned with power duality efficiency power loss analysis. This inverter is discussed as compared with those of tile three-phase voltage source type sinewave hard switching PWM inverter. The power loss analysis of this soft switching PWM Inverter using IGBT power modules is evaluated on the basis of the measured v-i characteristics and switching power losses of IGBT, and antiparaliel diodes. The practical effectiveness of this inverter is proven by the power loss analysis for distributed power supply.

  • PDF

Series Capacitor Compensated Resonant High Frequency Inverter with ZCS-Pulse Density Modulation fey Induction Heating Fixing Roller in Copy Machine

  • Ahmed T.;Shirai H.;Gamage L.;Soshin K.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.499-502
    • /
    • 2003
  • This paper presents the voltage source type half bridge lossless auxiliary inductor snubber assisted series capacitor compensated resonant high frequency inverter for induction heated fixing roller in copy machines. This high-frequency inverter treated here can completely achieve zero current soft switching (ZCS) commutation for wide power regulation range under its constant frequency pulse density modulation (PDM) scheme. Its transient and steady-state operating principle is originally presented fur a constant frequency PDM control strategy under a ZCS operation commutation, together with its output effective power regulation characteristics-based on the PDM strategy. The experimental operating performances of this ZCS-PDM high frequency inverter using IGBTs are illustrated as compared with computer simulation ones. Its power losses and actual efficiency are evaluated and discussed on the basis of simulation and experimental results.

  • PDF

고주파유도가열 철부하의 FTPM 및 PSPM 제어에 관한 연구 (The Study on FTPM and PSPM of High Frequency Induction-Heating Iron Load)

  • 임영도;김두영
    • 전력전자학회논문지
    • /
    • 제5권2호
    • /
    • pp.192-199
    • /
    • 2000
  • 본 논문은 고주파 유도 가열기의 전력조절을 위해 뉴로-퍼지 알고리즘을 이용하고, IGBT를 사용한 위상 전이 펄스변조(PSPM)와 주파수 추종 펄스변조(FEPM) 가 조절되는 공진 고주파 인버터를 응용한 유도가열기를 설명한다. 이는 실제로 산업 현장에서 20KHz~500KHz 유도 가열 및 유도 용해 전원장치용으로 쓰인다. 위상 전이 펄스변조 (PSPM) 정전력 조절 기술을 바탕으로 한 적응 주파수 추종기법은 스위칭 손실을 최소화하고 전력조절을 용이하게 하기 위해 소개되어졌다. 뉴로-퍼지제어기를 사용하여 만들어진 실험장치는 성공적인 논증과 토의가 되어졌다.

  • PDF

분산전원 연계 배전계통의 사고 특성 분석 (Analysis of a Fault Characteristics in the Power Network with Distributed Generators)

  • 장성일;박제영;최정환;정종찬;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.65-68
    • /
    • 2002
  • Distributed Generators (DG) are rapidly increasing and most of them are interconnected with distribution network to supply power into the network. Therefore, DG may make significant impacts on distribution system operation. protection, and control with respect to the voltage regulation, voltage flicker, harmonics, fault current levels, the losses of the network, etc. These impacts would be demerits for both of DG and distribution networks. And the operation of DG may be influenced by the abnormal grid condition such as disturbances occurred in the neighboring distribution feeders as well as the feeder directly connected with DG. This paper describes the influence of fault occurred in the interconnected power network on the DG operation and the impact of DG on the network load during the interruptions of utility power.

  • PDF

R22 대체냉매를 적용한 스크롤 압축기의 누설 특성에 관한 연구 (A Study on Leakage Characteristics of a Scroll Compressor with alternative Refrigerants of R22)

  • 윤영;김용찬;민만기
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.377-387
    • /
    • 2001
  • This paper presents leakage characteristics of a scroll compressor applying alternative refrigerants of R22 such as R407c and R410a under actual operating conditions. Because leakage in a scroll compressor produce significant losses and degradation of performance, those should be clarified to design a high efficient scroll compressor with alternative refrigerants of R22. However, flank and tip leakage characteristics of a scroll compressor with alternative refrigerants are very limited in open literature. In the present study, both experimentation and modeling of the leakages in the scroll compressor were performed. As a result, it was observed that the leakages of the scroll compressor with R407c increased by 15%, and that with R410a increased by 76% as compared to the compressor applying R22 under standard load conditions due to a higher upstream pressure and a higher pressure difference between pockets.

  • PDF

Novel High Step-Up DC/DC Converter Structure Using a Coupled Inductor with Minimal Voltage Stress on the Main Switch

  • Moradzadeh, Majid;Hamkari, Sajjad;Zamiri, Elyas;Barzegarkhoo, Reza
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2005-2015
    • /
    • 2016
  • A high-step-up DC/DC converter for renewable energy systems is proposed. The proposed structure provides high voltage gain by using a coupled inductor without the need for high duty cycles and high turn ratios. The voltage gain is increased through capacitor-charging techniques. In the proposed converter, the energy of the leakage inductors of the coupled inductor is reused. This feature reduces the stress on the switch. Therefore, a switch with low ON-state resistance can be used in the proposed converter to reduce losses and increase efficiency. The main switch is placed in series with the source. Therefore, the converter can control the energy flow from the source to the load. The operating principle is discussed in detail, and a steady state analysis of the proposed converter is conducted. The performance of the proposed converter is verified by experimental results.