Reliability Model for u-Health SW's BMT (u-Health SW의 BMT를 위한 신뢰성 모델)

  • Chung, Sam-Sool;Yang, Hae-Sool
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.80-89
    • /
    • 2010
  • u-Health refers to "Always, ubiquitously" prevention against disease, diagnosis, medical treatment service that can receive treatment even if patient does not visit hospital as abbreviated word of ubiquitous and health. U-Health transmits in individual's living body sign and measuring of health information and health information system that is consisted of process of analysis and feedback transmiting and measure individual's living body signal and health information and health proprietary company or medical institution operates. If analyze pattern to information that health information system is transmited, health care officer or chief physician means that offer healthcare and medical treatment service to remote about target customer. Wish to present authoritativeness model for u-Health's inside and outside of the country same native place and u-Health's BMT in this research.

Polymer/Metal Based Flexible MEMS Biosensors for Nerve Signal Monitoring and Sensitive Skin

  • Kim, Yong-Ho;Hwang, Eun-Soo;Kim, Yong-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.1
    • /
    • pp.11-16
    • /
    • 2005
  • This paper presents fabrication process and experimental results of two different types of flexible MEMS biosensors based on polymer/metal multilayer processing techniques. One type of a biosensor is a microelectrode array (MEA) for nerve signal monitoring through implanting the MEA into a living body, and another is a tactile sensor capable of being mounted on an arbitrary-shaped surface. The microelectrode array was fabricated and its electrical characteristics have been examined through in vivo and in vitro experiment. For sensitive skin, flexible tactile sensor array was fabricated and its sensitivity has been analyzed. Mechanical flexibility of these biosensors has been achieved by using a polymer, and it is verified by implanting a MEA to an animal and mounting the tactile sensor on an arbitrary-shaped surface.

Analysis of Changed Bio-Signal to Radiation Exposure of Nuclear Medicine Worker (핵의학 종사자의 방사선 피폭에 따른 생체신호 변화 분석)

  • Lee, Hwun-Jae;Lee, Sang-Bock
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • In this paper, We are evaluated about bio-signal between general workers and nuclear medicine workers which is more radiation exposure relatively. In order to reciprocal evaluated two group, we experimented nuclear medicine workers in Chung-Buk National University Hospital at department of nuclear medicine and worker in Chon-Nam National University Hospital at CT room, general radiographic room, medical recording room, receipt room, general office room. Used of experimental Equipments as follows, for a level of radiation measurement by pocket dosimeter which made by Arrow-Tech company, for heart rate and blood pressure measurement by TONOPORT V which made by GE medical systems company, for heat flux and skin temperature and energy expenditure measurement by Armband senseware 2000 which made by Bodymedia company. Result of experiment obtains as follows: 1) Individual radiation exposure is recorded 3.05 uSv at department of nuclear medicine and order as follows CT room, general radiograpic room, medical recording room, receipt room, general office room. Department of nuclear medicine more 1.5 times than other places. 2) Radiation accumulated dose is not related to Heat flux, Skin temperature, Energy expenditure. 3) Blood pressure is recorded equal to nuclear medical workers, general officer, general people about systolic blood pressure and diastolic blood pressure. Compared to blood pressure between nuclear medical works which is more radiation exposure and other workers was not changed. Consequently, more radiation exposed workers at nuclear medicine field doesn't have hazard.

A Study on the Implementation of Real-time Digital Filter System for the Baseline Wandering Elimination (기저선 변동 제거를 위한 실시간 디지털 필터 시스템 구현에 관한 연구)

  • 윤승구;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.512-515
    • /
    • 2001
  • The heifer electrocardiograph is a widely progressing research which is used in judgement to existence for a heart disease and analyzes electric potential changes of heart movement during continuous living of everyday after attaching to body portable holler recorder for twenty-four hours. In order to obtain electrocardiogram clearly, it must eliminate that 60Hz power line interference, baseline wandering, noise of muscle constriction. In holter electrocardiogram, the most big problem which is recorded signal of ECG(electrocardiogram) is a baseline wandering elimination, which is occurred by rhythm of respiration and muscle constriction of part from attaching to an electrode. Such baseline is roughly irregular wandering and shaking up and down therefore the part of baseline wandering elimination is very important because it is difficult of ECG diagnosis. In this study, it is stabilized baseline wandering in analog part as implementation f real-time signal processing digital filter so it is applicable to analyze patient's heart disease by way of design of baseline wandering elimination system.

  • PDF

Implementation of Real-time Heart Activity Monitoring System Using Heart Sound (심음을 이용한 실시간 심장 활동 상태 모니터링 시스템 구현)

  • Kim, Jin-Hwan;Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.1
    • /
    • pp.14-19
    • /
    • 2018
  • Recently, the smart health care industry has been rising rapidly and interest and efforts for public health have been greatly increased. As a result, the public does not visit medical specialists and medical facilities, but the desire to check their health condition in everyday life is increased. Therefore, many domestic and foreign companies continuously research and develop wearable devices that can measure body activity information anytime and anywhere And the market. Especially, it is used for heart activity measurement device using pulse wave sensor and electrocardiogram sensor. However, in this study, a monitoring system that can detect cardiac activity using cardiac sounds, heart sound measurement rather than pulse wave measurement and electrocardiogram measurement, was performed and its performance was evaluated. Experimental results confirmed the predictability of cardiac heart rate and heart valve disease during daily living.

Extraction of Face Type and Tongue Color Analysis for Diseases Diagnosis in Web-Based Environments (웹 기반 환경에서 질병 진단을 위한 얼굴형 추출 및 설색 분석)

  • Cho, Dong-Uk;Kim, Bong-Hyun;Lee, Se-Hwan
    • The KIPS Transactions:PartB
    • /
    • v.14B no.2
    • /
    • pp.71-80
    • /
    • 2007
  • In this paper, We propose face type classification, tongue region extraction and tongue color analysis method for Oriental medicine diagnosis system to supply web based medical treatment information. This presents to construct system that takes super aging society and uses ocular inspection and longue diagnosis in web-based to embody this by an IT Technology as generalization and popularization of medical benefit are social requirement and supplies medical treatment information. Place that reflect living body signal of human body ordinarily and appear becomes iris or tongue, five sensory organs etc. This paper proposes classification of face type, extraction of five sensory organs for observing a person's shape and color among diseases diagnosis based on home health care that propose to develop and region extraction and color analysis etc, of tongue which intensively represents the bio-signals of human-beings. Finally, the effectiveness of this paper is verified by several experiments.

Analyses on Physiological Meanings of Yin Yang through Comparison of Ying-Wei Theory and Sleep-Awakening System (영위생리와 각성.수면시스템의 비교를 통한 음양(陰陽)의 함의(含意) 분석)

  • Lee Sang-Man;Eom Hyun-Sup;Chi Gyoo-Yong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.5
    • /
    • pp.1154-1161
    • /
    • 2005
  • Yin Yang theory is the first and the last one to interpret diseases apply to treatment in oriental medicine. So it is regarded as the way of heaven and earth, the discipline of all things, the origin of change, the beginning of giving birth and death, the source of spirit. These regulatory passages are needed to compare with western medical physiology and analyzed whether it has scientific bases or not. The Yin Yang theory of traditional oriental medicine are summerized from the descriptions of Scripture of Documents, Ying Wei theory of Huangdi Neijing. Meanwhile up-to-date neurobiological and molecular genetic theories on circadian physiology are reviewed in western medicine. Sunshine is transferred through RGC to SCN, herein the central circadian rhythm is made by zeitgeber and interaction of melatonin secreted from pineal body and orexin from mp pan of hypothalamus. So HPA axis is activated and controlled under the circadian rhythm and affects peripheral tissues and cells of whole body through glucocorticoid hormones. First of all, the circadian rhythm makes the basic patterns of human life in biological and sociological meaning. It is almost same context with the record of the Scripture of Documents. Also the Ying Qi and Wei Qi is basically same with the sleep-awake mechanism, that is melatonin/orexin signal or per/clk/bmal/cry genes with circadian activation and activity of each organ's physiological function. Conclusively it can be said that Yin Yang is a priori principle of living things and the beginning of giving birth and death for activation of them biologically, as is described in Huangdi Neijing.

Study on the Immersion by the American Audience's Biotic Response to Narrative of and (<블라인드 사이드>와 <행오버>의 서사에 대한 미국 관객의 생체반응에 의한 몰입도 연구)

  • Woo, Jeong-Gueon
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.2
    • /
    • pp.652-660
    • /
    • 2018
  • The common point between and is that the immersion was high at the point where all the place movements occurred in the narrative before the full-blown incident occurred. The immersion level showed the maximum at the turning point that passed to the place. Seven key events occur, and the audience's immersion is peaking at the time of each incident. The core event and the immersion are highly correlated. It is at a point where the background, such as movement from the third act, where the most central event is solved, or return to the original place, is changing. The immersion degree of the audience is closely related to the narrative from the first film to the third film of the narrative.

Face Feature Extraction for Child Ocular Inspection and Diagnosis of Colics by Crying Analysis (소아 망진을 위한 얼굴 특징 추출 및 영아 산통 진단을 위한 울음소리 분석)

  • Cho Dong-Uk;Kim Bong-Hyun
    • The KIPS Transactions:PartB
    • /
    • v.13B no.2 s.105
    • /
    • pp.97-104
    • /
    • 2006
  • There is no method to control for the child efficiently when disease happens who cannot be able to express his symptoms. Therefore, doctor's diagnosis depends on inquiring from child's patients, that leads to wrong diagnosis result. For this, in this paper, we would like to develop child ocular inspection, auscultation diagnosis instruments, using Oriental medicine principle that living body signal of five organs and six hallow organs which reflects patients face and voice We would like to get more accurate diagnosis result for child's symptoms from doctor's intuition on the basis of diagnostic sight visualization, objectification, quantization itself. This paper develops color revision, YCbCr application, and face color selection and five sensory organs and nose or apex extraction method etc, in child ocular inspection by first work achievement sequence among the whole development systems. Also, in occasion of child auscultation, crying characteristics of colics through pitch, intensity and formant analysis is numerized and objectifies doctor's intuition through this. Finally, experiments are performed to verify the effectiveness of the proposed methods.

Experimental Verification of Implantable Middle Ear System using the Differential Electromagnetic Type Transducer (차동 전자 트랜스듀서를 이용한 이식형 인공중이 시스템의 실험적 검증)

  • 송병섭;이기찬;원철호;박세광;이상흔;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.217-225
    • /
    • 2002
  • The implantable middle ear(IME) system, which has good sound quality. superior sound intelligibility and wide frequency characteristics. can resolve the sound distortion and ringing effect by sound feedback at high gain operation those are the major problems of conventional hearing aid. In this paper, we have manufactured the IME system using differential electromagnetic transducer(DET) and verified the performance of the system by carrying out vibration and animal implanting experiment. The DET was manufactured using micro-machining technology and vibration experiment of the transducer was performed to inspect whether the transducer could vibrate in accordance with the applied sound signal or not. And the result of the loaded experiment using temporal bone sampled from cadaver showed that the transducer can drive the middle ear bone and transmit the signal to inner ear After the internal unit of IME system was implanted in a dog. the auditory brainstem response (ABR) test was carried out. The result of the test indicated the Proper behavior of the IME system in the living body From the results of the experiments, it is verified that the manufactured system ewll work well when it is applied to human and a basis of clinical experiment of IME system to real human hearing impaired was be arranged.