• 제목/요약/키워드: Lissajous Figure

검색결과 12건 처리시간 0.024초

V-Q Lissajous' Figure을 이용한 AC-PDP 최적 구동 조건에 관한 연구 (A Study on the Optimum Driving Conditions of AC-PDP using the V-Q Lissajous‘ Figure)

  • 조우성;최창훈;김영조;박선우;노승용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.128-131
    • /
    • 2002
  • In this paper, we used the V-Q Lissajous‘ figure for studying on the plasma discharge characteristics of the 42 inches AC-PDP. From the V-Q Lissajous‘ figure, we could observe exactly the driving conditions that the self-erasing discharge takes place. At the time, the total wall charges lessened by self-erasing discharge was calculated quantitatively. Beside of the just observation of self-erasing discharge and calculation of the charges lessened, we could find out the optimum driving conditions for inducing the maximum wall charges accumulated on the dielectric layer with measuring the Wall voltage from the V-Q Lissajous' figure.

  • PDF

AC-PDP 구동에 있어서 V-Q Lissajous' Figure을 이용한 벽전하 거동분석 (Analysis of Wall-charge behavior using V-Q Lissajous' figure in AC-PDP driving)

  • 정종갑;조우성;최창훈;주병권;박선우;김철주;노승용;김영조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.111-115
    • /
    • 2002
  • To understand the discharge characteristics in AC-PDP, it is necessary to study on the wall charge behavior. But, it is difficult to measure the wall charge directly. In this paper, the V-Q Lissajous' figure is used to measure the wall charge indirectly and analyze the wall charge behavior. With the V-Q Lissajous' figure, the discharge characteristics of AC-PDP are studied according to vary driving conditions, such as the frequency, pulse duty ratio, and rising & falling time. As a result, the V-Q Lissajous' figure is used to measure the discharge characteristics of the AC-PDP. It is confirmed that firing initial voltage and firing final voltage for discharge are effected by the aboved variables. Related with the wall voltage generation, it is thought that the difference of the slope at the V-Q Lissajous' figure is caused by charged ions inside the dielectric layer.

  • PDF

V-Q lissajous 도형을 이용한 전계발광 소자의 메모리 특성 측정 (Memory Characteristic Measurement of Electroluminescent Device using V-Q Lissajous' Figure)

  • 정득영;임민수;윤성현;신유섭;권순석;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1783-1785
    • /
    • 1999
  • In this paper, we apply V-Q Lissajoucs' figure for observation of a V-Q (Voltage-Charge) hysteresis loop at interface between phosphor and insulation layer in P-ELDz which are a simple structure and the back lighting of LCDs (Liquid Crystal Display). In V-Q Lissajous' figure, we measured a change of hysteresis loop according to the thickness of Insulation and phosphor layer. From experiment result, we will be obtained a optimum thickness of insulation with comparing the correlation of a V-L (Voltage-Luminance) and V-Q hysteresis loop.

  • PDF

인가 전압의 변화에 따른 FFL(Flat Fluorescent Lamp)의 방전특성 (Discharge characteristics of FFL as applied voltage variation)

  • 윤성현;박철현;조민정;임민수;권순석;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.379-382
    • /
    • 2000
  • The characteristics of Xe discharge lamp(Mercuryless lamp) are described in this paper. In this paper, FFL is operated by sine wave and pulsed source. We apply V-Q Lissajous' figure for the discharge measurements of FFL which has the electrodes covered with dielectric. When FFL is operated by sine wave source, the characteristics are similar to DBD(Dielectric Barrier Discharge) and SD(Silent Discharge). And we compared the characteristics of FFL which is operated with sine wave and pulsed discharge by using V-Q Lissajous' figure method. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. As the duty ratio increases the electric field becomes strong and much more xenon ions are produced. And the number of metastable xenon atoms seem to increase, therefore, the phosphor radiation after the cut off of voltage increases compared with the first peak of radiation. Consequently, the 172㎚ radiation becomes strong as the duty ratio increases.

  • PDF

Measurement of Dynamic Compressive Properties of Apples using the Oscillatory Test

  • Lee, Jong-Whan;Tan, Jinglu;Waluyo, Sri
    • Journal of Biosystems Engineering
    • /
    • 제37권1호
    • /
    • pp.28-35
    • /
    • 2012
  • Purpose: This study performed the oscillatory test using the texture analyzer to characterize the viscoelastic behavior of apples such as the storage modulus (E'), the loss modulus (E"), the complex modulus (${\mid}E^*{\mid}$) and the energy dissipated per cycle ($W_{diss}$). Methods: The sinusoidal deformation with the frequency of 1-10 Hz and the maximum displacement of 0.1 mm were applied to the flesh tissues of Fuji, Golden Delicious and Red Delicious apples. The Lissajous figure was used to measure the phase angle(${\delta}$) between stress and strain curve. Results: Trigger force was critical to the measurement of the phase angle. E', E", ${\mid}E^*{\mid}$ and Wdiss were measured using the Lissajous figure and the phase angle. The complex modulus of Golden Delicious apple was significantly lower than those of Fuji apple and Red Delicious apple. Conclusions: Apple flesh was exhibiting more elasticity at low frequency, and more viscosity at high frequency. Dynamic compressive properties of Fuji apple were similar to those of Red Delicious apple but significantly different from those of Golden Delicious apple.

Quadrature-detection-error Compensation in a Sinusoidally Modulated Optical Interferometer Using Digital Signal Processing

  • Hwang, Jeong-hwan;Park, Chang-Soo
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.204-209
    • /
    • 2019
  • In an optical interferometer that uses sinusoidal modulation and quadrature detection, the amplitude and offset of the interference signal vary with time, even without considering system noise. As a result, the circular Lissajous figure becomes elliptical, with wide lines. We propose and experimentally demonstrate a method for compensating quadrature detection error, based on digital signal processing to deal with scaling and fitting. In scaling, fluctuations in the amplitudes of in-phase and quadrature signals are compensated, and the scaled signals are fitted to a Lissajous unit circle. To do so, we scale the average fluctuation, remove the offset, and fit the ellipse to a unit circle. Our measurements of a target moving with uniform velocity show that we reduce quadrature detection error from 5 to 2 nanometers.

오존발생을 위한 알루미나 방전관의 무성방전특성 (Silent Disicharge Characteristics of Alumina Discharge Tube for Ozone Generation)

  • 김학규;곽동주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.783-786
    • /
    • 2001
  • Recently deep interests and attractions have been paid on the generation of ozone, which is widely used to remove bad smell and to clear water. Silent discharge is considered as one of the most effective methods to generator ozone. In this paper, silent discharge reactors were made, waich were filled with different dielectric materials, and some silent discharge charactistics were investigated experimantaiiy.

  • PDF

FFL(Flat Fluorescent Lamp)의 방전 특정 (Discharge characteristics of Flat Fluorescent Lamp)

  • 권순석;류장렬
    • 전자공학회논문지 IE
    • /
    • 제44권1호
    • /
    • pp.1-5
    • /
    • 2007
  • 본 논문에서는 FFL에 대한 기초 방전특성의 일부분으로 인가전압을 정현파와 구형파로 변화시켜 V-Q Lissjous 도형을 이용하여 FFL의 방전형태를 분석하고, 인가전압의 듀티비(duty ratio)의 면화에 의한 radiation transition에 대하여 고찰하였다. FFL을 정현파와 펄스파을 이용하였고, 절연층으로 둘러 쌓여 있는 전극을 갖는 FFL의 방전 특성을 V-Q 리사쥬 도형을 이용하여 방전 특성을 고찰하였다. FFL은 펄스파로 구동하였을 때 방전 전류는 전압의 상승 순간에 방전 전류가 흐른다. 듀티비가 증가하면 준안정 준위의 Xe 원자들은 증가하며 172nm의 자외선 방사량이 증가하고 있음을 확인할 수 있었다.

기체온도 측정을 위한 초음파 계측에 관한 연구 (A Study on Ultrasonic Technique for Measuring Gas Temperature)

  • 윤천한;최영;전흥신
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.893-900
    • /
    • 1999
  • Measuring temperature with ultrasonic wave apparatus is desirable in the cue of gas below $300^{\circ}$ because of the fact that the temperature of gas is the function of only sound velocity. In this study, being used a heatable wind channel and a blower. the variation of temperature is observed in accordance with flow rate(air velocity). The frequency modulation method is used to measure the temperature which is varying in hot air flow up to $100^{\circ}$. The length changed in the position of ultrasonic sensors is considered. Also. the effects of air velocity at the same temperature and various facing angles of ultrasonic sensors are considered. As a result of this study. it has been found that the temperature in gas flow is correctly measured regardless of both the distance of ultrasonic sensors and the variation of air velocity. and that there is just a little influence of facing angles.