Monte Carlo 계산에 의한 액체섬광계수기의 베타선 스펙트럼 Simulation (Simulation of Beta Ray Spectra in Liquid Scintillation Counting System by means of Monte Carlo Method)

  • 이철영;전재식
    • Journal of Radiation Protection and Research
    • /
    • 제18권2호
    • /
    • pp.17-25
    • /
    • 1993
  • 액체섬광 계수기에 대한 $^3H,\;^{14}C,\;^{36}Cl$의 베타선 스펙트럼의 시뮬레이션을 Monte Carlo 법으로 수행하였다. 베타선의 손실에너지는 'continuous slowing down approximation(CSDA)' 모형으로부터 구하였다. 순 베타방출 핵종이 균일하게 용해되어 있는 섬광용액은 $1.25cm{\times}3.5cm$의 원통형 geome try로 가정하였다. $^{14}C,\;^{36}Cl$에 대한 계산결과는 계수효율의 경우 실험 값과 2%의 범위 내에서 잘 일치하였으나 $^3H$에 대해서는 상당한 편차를 나타내었다. 이는 저 에너지 베타선에 대한 섬광용액 자체의 quenching 효과에 기인하는 것으로 판단된다.

  • PDF

방사성탄소연대측정 (Radiocarbon Dating)

  • 이현주;황진주;백현주
    • 보존과학연구
    • /
    • 통권23호
    • /
    • pp.197-214
    • /
    • 2002
  • It is very important to determine the age of the Cultural Properties in archeology. In about 1950, W.F. Libby and a team of scientists at the University of Chicago developed the Radiocarbon Dating technique. Radiocarbon($^14$C) Dating is probably one of the most widely used and best known absolute dating methods. Radiocarbon ages are conventionally specified to the year 1950. This year is 0 BP year. BP is the initial of Before Present. The $^14$C within an organism is continually decaying into stable carbon isotopes. When $^14$C decays, it emits a $\beta$ - particle with an energy content of 156 KeV and becomes 14N. Only the $\beta$ - particle is detected by Liquid Scintillation Counting. $^14$C has a half life of 5730 years. It has been used to date samples as old as 50,000 years. Radiocarbon determinations can be obtained on organic material : wood, charcoal, shell, etc. The results of radiocarbon dating using Benzene Synthesizer and Liquid Scintillation Counter are KCP539 $4030\pm60$BP year, KCP540 $3980\pm60$BP year, KCP575 $4870\pm50$, KCP576 $100\pm50$BP year, KCP577 $130\pm50$BP yea and KCP578 $210\pm70$BP year.

  • PDF

$C^{14}O_2$의 흡수제(吸收劑)로서 폐닐에칠아민과 하이아민베이스의 비교(比較) (Comparison of Phenyl Ethylamine and Hyamine Base as an Absorbent of $Carbon^{14}$ Dioxide)

  • 장윤환
    • Applied Biological Chemistry
    • /
    • 제14권1호
    • /
    • pp.51-57
    • /
    • 1971
  • $CO_2$의 흡수능력(吸收能力)을 비교(比較)하기 위(爲)하여 습윤연소실험(濕潤燃燒實驗)에 있어서 Phenyl Ethylamine과 Hyamine Base를 사용(使用)하였다. 알려지고 있는 간장지질(肝藏脂質)과 균일(均一)하게 혼합(混合)된 팔미딘산-$C^{14}$을 유산(硫酸)과 인산(燐酸)으로 산화(酸化)하였다. 생성(生成)된 $CO_2$를 가느다란 비닐관(管)을 통하여 공시(供試)아민제(劑)에 포착(捕捉)시켰다. $CO_2$를 흡수(吸收)한 아민 제(劑)들을 Diotal Scintillator와 혼합(混合)하고 Liquid Scintillation Counter에 의(依)하여 그 방사능(放射能)을 측정(測定)하였다. 공시(供試)한 2종(種)아민의 계측효율(計測效率)은 $50{\sim}60%$이 었으며 방사능회수율(放射能回收率)은 거의 100%이었다. 그러나 Phenyl Ethylamine에 의(依)한 $CO_2$흡수량(吸收量)이 Hyamine Base의 그것에 비(比)하여 약(約) 2배(倍)가 되었으며 취급(取扱)하기도 용이(容易)하고 대금(代金)도 싸기 때문에 $CO_2$ 흡수제(吸收劑)로서는 Phenyl Ethylamine을 사용(使用)함이 좋을 것이다. 한편 돼지의 간장실험(肝藏實驗)에 있어서 지질(脂質)을 $CO_2$로 변화(變化)시켜 $C^{14}$의 방사능(放射能)을 측정(測定)하는 것이 지질(脂質)을 그대로 계측(計測)하는 것보다 계측효율(計測效率)이 더 증가(增加)되지 않음이 밝혀졌다.

  • PDF

분말활성탄을 이용한 극미량 농도 Nitrosomethylamine의 흡착 제거 (Removal of Nitrosomethylamine at Extremely Low Concentration by Powdered Activated Carbon)

  • 이성범;윤여민;최창규;김문일
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.413-416
    • /
    • 2008
  • Recently, the results of vital tissue test showed that nitrosodimethylamine (NDMA) as a disinfection by-product (DBP), could be regarded as a carcinogen because a tumor was observed in organs. U.S.EPA indicated 0.7 ng/L as exposure concentration of NDMA based on a risk assessment target with a lifetime cancer risk of $10^{-6}$. Several recent studies have shown that UV oxidation could remove NDMA. However, UV oxidation is uneconomical and can reform NDMA after treating. In addition, the treatment mechanism of adsorption has not been founddue to the uncertainty of NDMA pathway. In addtion, NDMA has a radioisotope $^{14}C$-labeled which can be analyzed at low concentration of NDMA by Liquid Scintillation Counter (LSC). This study has investigated NDMA determination using LSC at an extremely low range from 1 to 100 ng/L and NDMA removal by powdered activated carbon (PAC) adsorption. For $^{14}C$-NDMA by LSC, the highest correlation over 99% between count number and NDMA concentrationwas obtained with possibility of $^{14}C$-NDMA concentration up to 1 ng/L. In the presence of PAC ranging from 50 to 10,000 mg/L, $^{14}C$-NDMA was removed from 18% to 97% for Sigma-Aldrich corporation (S-A co.) and from 9% to 93% by PAC for Daejung corporation (Dj co.). Hence it was found that the removal efficiency by PAC adsorption could vary depending on PAC types from different companies. For PAC adsorption capacity of $^{14}C$-NDMA using the Freundlich isotherm, $K_f$ and 1/n of PAC from S-A co. were $2.67\times10^{-3}$ ng/mg and 1.009, while those of PAC from Dj co. were $1.30\times10^{-3}$ ng/mg and 0.994, respectively. Thus, PAC from S-A co. showed twice higher adsorption capacity than Dj co.

  • PDF

Analytical method for determination of 41Ca in radioactive concrete

  • Lee, Yong-Jin;Lim, Jong-Myoung;Lee, Jin-Hong;Hong, Sang-Bum;Kim, Hyuncheol
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1210-1217
    • /
    • 2021
  • The analysis of 41Ca in concrete generated from the nuclear facilities decommissioning is critical for ensuring the safe management of radioactive waste. An analytical method for the determination of 41Ca in concrete is described. 41Ca is a neutron-activated long radionuclide, and hence, for accurate analysis, it is necessary to completely extract Ca from the concrete sample where it exists as the predominant element. The decomposition methods employed were the acid leaching, microwave digestion, and alkali fusion. A comparison of the results indicated that the alkali fusion is the most suitable way for the separation of Ca from the concrete sample. Several processes of hydroxide and carbonate precipitation were employed to separate 41Ca from interferences. The method relies on the differences in the solubility of the generated products. The behavior of Ca and the interfering elements such as Fe, Ni, Co, Eu, Ba, and Sr is examined at each separation step. The purified 41Ca was measured by a liquid scintillation counter, and the quench curve and counting efficiency were determined by using a certified reference material of known 41Ca activity. The recoveries in this study ranged from 56 to 68%, and the minimum detectable activity was 50 mBq g-1 with 0.5 g of concrete sample.

감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구 (Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter)

  • 주병규;김문수;김현구;김동수;조성진;양재하;박선화;김형섭;권오상;김태승
    • 분석과학
    • /
    • 제28권3호
    • /
    • pp.228-235
    • /
    • 2015
  • 본 연구는 지하수 중 라듐(226Ra) 분석을 위해 고상추출디스크(solid phase extraction disk)를 이용한 감마선분광분석법(이하 고상추출디스크법)을 제안하고 액체섬광계수기를 이용한 액체섬광계수(liquid scintillation counter, LSC)법 및 마리넬리비커(Marinelli beaker)를 이용한 감마선분광분석기(gamma ray spectrometer)법(이하 마리넬리비커법)과의 회수율 비교를 통해 적용성을 검토하였다. 226Ra을 회수한 고상추출디스크는 딸핵종의 방출을 방지하기 위해 폴리에틸렌 필름으로 밀봉 후 감마선분광분석기로 분석하였다. 24일 경과 후, 226Ra과 딸핵종인 214Bi과 214Pb이 방사평형 된 것으로 확인되었다. 라듐 표준물질을 이용하여 고상추출디스크법으로 분석한 딸핵종 214Bi와 214Pb의 회수율은 각각 80% (295.21 Kev)와 104% (351.92 Kev)로 액체섬광계수법보다 높게 나타났다. 바탕시료(blank) 측정시 감마선분광분석기 챔버내 질소를 주입했을 경우는 주입하지 않았을 경우보다 간섭치가 약 10% 이하로 낮아지는 것을 확인하였으며, 5 L 시료를 8만초 동안 측정한 검출한계는 0.17~0.40 pCi/L로 분석되어 미국 EPA 기준치인 1pCi/L를 만족하였다. 고상추출디스크법과 액체섬광계수법을 이용한 7개 지하수 시료 분석 결과, 두 방법의 상관계수(correlation coefficient)는 0.987로 나타나 추가적인 분석을 통해 통계적 유의성을 확보한다면 고상추출디스크법의 적용가능성이 높을 것으로 판단된다. 결과적으로, 고상추출디스크법을 이용한 지하수 중 226Ra 농도 분석은 전처리 과정이 비교적 단순하여 분석시간이 절약되고 높은 회수율과 낮은 검출한계치 등의 장점을 가지고 있는 것으로 분석되었다. 또한 고상추출디스크법은 액체섬광계수법과 마리넬리비커법에 비해 많은 양의 시료를 전처리하기 쉽기 때문에 저준위 시료 분석에 유용할 것으로 판단된다.

지하수 중 222Rn 분석을 위한 정도관리 (QA/QC for 222Rn analysis in groundwater)

  • 정도환;김문수;김현구;김혜진;박선화;한진석;주병규;전상호;김태승
    • 분석과학
    • /
    • 제26권1호
    • /
    • pp.86-90
    • /
    • 2013
  • 짧은 반감기(3.82일)로 인하여 표준물질이 없어서 $^{226}Ra$ 표준선원을 이용하여 액체섬광계수기(Liquid Scintillation Counter)의 측정효율을 산정한 후 구하는 $^{222}Rn$ 농도 분석의 정도 관리를 위해서 blank(바탕)시료, 중복시료, 원수 채취전과 후의 시료 분석을 수행하였다. 현장 바탕시료는 0.44~6.28 pCi/L, 실험실 바탕시료는 1.66~4.95 pCi/L 값을 보였다. 둘 사이의 상관계수는 0.9691이였으며, 현장시료채취, 시료 이동, 시료 보관 상태에서 다른 오염원은 없었음을 확인하였다. 65개의 원시료와 중복시료의 상관계수는 0.9987을 보였다. 라돈은 불활성 기체이므로 시료를 채취할 때 손실에 의해 지하수 중 라돈 농도에 영향을 미칠 것으로 사료되어 증류수를 이용하여 현장 지하수 시료 채취 전과 후로 구분하여 비교분석하였으나 유의한 농도차이를 보이지 않았다.

연두금파리의 발생에 따른 cyclic AMP, cyclic AMP-Dependent Protein Kinase, Ecdysteroids의 변화 (Wariations in cyclic AMP, cyclic AMP-Dependent Protein Kinase and Ecdysteroids during Development of the Blowfly, Lucilia illustris)

  • 김유경;류진수이경로
    • 한국동물학회지
    • /
    • 제37권4호
    • /
    • pp.565-572
    • /
    • 1994
  • 연두금파리의 유충-번데기-성충의 발생에 따른 cyclic AMP(CAMP)와 ecdysteroids의 농도 및 cyclic AMP-dependent protein kinase(PKA)의 활성도를 High Performance Liquid Chromatography(HPLC)와 Liquid Scintillation Counter(LSC)를 이용하여 측정하고 상관 기능 변화를 조사하였다. CAMP의 농도와 PKA의 활성도는 종령유충 및 성충에서 낮은 갓(0.29 UM/g, 5.52~5.59 unit/mg)을 나타내었고 번데기 0일(0.49 UM/g. 92.22 unit/mg)과 7일(0.50UM/g, 24.45 unit/mg)에서 최고치를 보였으며 번데기 4일에서 최저수준(0.13 $\mu$M/g3.23 unit/mg)을 나타내었다. Ecdysone 농도는 번데기 2일에 최고치(37 84 USlg)를 4일에 최저치(18.46 Ugyg)를 보인 후, 5일에 24.37 1519로 상승하였으며 성충에서는 낮은 값을 나타내었다 그러나 20-hydroxvecdysone 농도는 번데기 4일(23.66 UgyS)과 번데기 6일(14.90 Ugyg)에 최고치를 이루었고, 7일에서 최저치(1.21 USi9)를 나타내었다.

  • PDF

A STUDY ON THE SIMULTANEOUS MEASUREMENTS OF BETA EMITTING ISOTOPES

  • Lee, Goung-Jin;Kim, Seoung-Pyung
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.155-159
    • /
    • 2001
  • Beta radiation is measured for an environmental monitoring purpose or for an internal radiation exposure monitoring of nuclear power plant's worker. In korea, strontium 89 and strontium 90 is measured for an environmental monitoring purpose. Also tritium and carbon 14 contained in urine is measured for an internal radiation exposure monitoring of nuclear power plant's worker. Because above isotopes emits low energy beta radiations having a wide range of energy, very complicated isotope separation preprocess is needed. In this study, two mixed beta emitting isotopes are measured simultaneously using a liquid scintillation counter(LSC) and analyzed by using a developed statistical method. Banded least square method is used to analyze the mixed spectrum, and the goodness-of-fitness test is proposed. Test results show that the developed procedure can be very useful for analyzing a mixed beta emitting isotopes.

  • PDF

저준위 액체섬광계수기와 파형분석법을 이용한 지하수중의 $^{222}Rn$ 측정 (Measurement of $^{222}Rn$ in ground water with low-level Liquid Scintillation Counter and pulse shape analysis)

  • 조수영;윤윤열;이길용;김용제
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2006년도 총회 및 춘계학술발표회
    • /
    • pp.319-323
    • /
    • 2006
  • 파형분석(PSA) 기능과 백그라운드 낮고 계측효율이 높은 장점을 가지고 있는 저준위 액체섬광계수기를 이용하여 지하수중의 $^{222}Rn$ 측정을 위한 최적 분석조건을 확립하였다. 라돈분석을 위해 섬광용액 HiSafe 3 12 ml를 사용하여 물시료 8 ml 내 $^{222}Rn$ 을 측정하였다. 라돈은 딸핵종과의 방사평형을 위해 3시간동안 방치한 후 계측하였다. 최적 파형분석 (PSA) 준위는 100 이었다. $^{222}Rn$의 계측효율은 $^{226}Ra$ 표준시료를 동일 조건으로 제조한 후 약 20일 이상 방치한 다음 측정하여 결정하였으며 측정효율은 약 $91.6{\pm}3.6%$ 이었다. 동일 시료의 라돈 추출실험 재현성은 2 % 이내이었다. 계측시간 10시간을 기준으로 바탕값은 0.035 cpm 이었고 300분 계측시 검출하한값은 0.11 Bq/L 이었다.

  • PDF