• Title/Summary/Keyword: Liquid Conductivity

Search Result 413, Processing Time 0.032 seconds

Estimation of Thermal Conductivity at Liquid and Vapor Interface by Molecular Dynamics Simulation (분자동역학을 이용한 액상과 기상계면에서의 열전도율 예측)

  • Koo, Jin-Oh;Choi, Young-Ki;Lee, Joon-Sik;Park, Seung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1558-1563
    • /
    • 2004
  • This work applies the nonequilibrium molecular dynamics simulation method to study a Lennard-Jones liquid thin film suspended in the vapor and calculates the thermal conductivity by linear response function. As a preliminary test, the thermal conductivity of pure argon fluid are calculated by nonequilibrium molecular dynamics simulation. It is found that the thermal conductivity decrease with decreasing the density. When both argon liquid and vapor phase are present, the effects of the system temperature on the thermal conductivity are investigated. It can be seen that the thermal conductivity of liquid-vapor interface is constant with increasing the temperature

  • PDF

Measurement of Thermal Conductivity of Foods in Liquid and Solid Phase Using a Thermal Probe

  • Hong, Ji-Hyang;Han, Young-Joe;Chung, Jong-Hoon
    • Food Science and Biotechnology
    • /
    • v.14 no.3
    • /
    • pp.334-339
    • /
    • 2005
  • An instrument using thermal probe method was designed to measure thermal conductivity of liquid and solid foods. Thermal conductivity probe was designed with diameter to length ratio of 100 and diameter of 0.51 mm to minimize axial flow effect on thermal conductivity measurement. Thermal conductivities of distilled/deionized water, glycerin, and beef frankfurter meat were measured at $20-80^{\circ}C$. Mean thermal conductivity values of water showed less than 2.0% difference from several reference values without using time correction factor or probe calibration constant. For glycerin, difference was less than 0.7% from reference values at $20-50^{\circ}C$. Mean values of thermal conductivity for beef frankfurter meat ranged from 0.389 to $0.350\;W/m{\cdot}K$ at $20-80^{\circ}C$.

A Study on the Measurement and Comparison(IEC 60079-32-2) of Flammable Liquid Conductivity (인화성 액체 도전율에 관한 측정 및 비교(IEC 60079-32-2) 연구)

  • Lee, Dong Hoon;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.22-31
    • /
    • 2019
  • The flammable liquid conductivity is an important factor in determining the generation of electrostatic in fire and explosion hazardous areas, so it is necessary to study the physical properties of flammable liquids. In particular, the relevant liquid conductivity in the process of handling flammable liquids in relation to the risk assessment and risk control in fire and explosion hazard areas, such as chemical plants, is classified as a main evaluation item according to the IEC standard, and it is necessary to have flammable liquid conductivity measuring devices and related data are required depending on the handling conditions of the material, such as temperature and mixing ratio for preventing the fire and explosion related to electrostatic. In addition, IEC 60079-32-2 [Explosive Atmospheres-Part 32-2 (Electrostatic hazards-Tests)] refers to the measuring device standard and the conductivity of a single substance. It was concluded that there is no measurement data according to the handling conditions such as mixing ratio of flammable liquid and temperature together with the use and measurement examples. We have developed the measurement reliability by improving the structure, material and measurement method of measuring device by referring to the IEC standard. We have developed a measurement device that is developed and manufactured by itself. The test results of flammable liquid conductivity measurement and the data of the NFPA 77 (Recommended Practice on Static Electricity) Annex B Table B.2 Static Electric Characteristic of Liquids were compared and verified by conducting the conductivity measurement of the flammable liquid handled in the fire and explosion hazardous place by using Measuring / Data Acquisition / Processing / PC Communication. It will contribute to the prevention of static electricity related disaster by taking preliminary measures for fire and explosion prevention by providing technical guidance for static electricity risk assessment and risk control through flammable liquid conductivity measurement experiment. In addition, based on the experimental results, it is possible to create a big data base by constructing electrostatic physical characteristic data of flammable liquids by process and material. Also, it is analyzed that it will contribute to the foundation composition for adding the specific information of conductivity of flammable liquid to the physical and chemical characteristics of MSDS.

Simultaneous Measurement of Liquid-level, Concentration and Temperature of a Urea Tank using Ultrasonic and Electrical Conductivity Sensors (초음파와 전기전도 센서를 이용한 우레아 탱크 수위, 농도 및 온도의 동시 측정 방안)

  • Choi, Byungchul;Kim, Taewook
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.71-78
    • /
    • 2017
  • The purpose of this study is to propose the basic data for the development of a sensor capable of simultaneously measuring the liquid-level, concentration and temperature of a urea tank using ultrasonic and electrical conductivity sensors for diesel vehicles with a urea-SCR system. It was found that the liquid-level of the urea tank using the ultrasonic sensor showed a good linearity with the actual liquid-level, and the urea concentration maintained good linearity in the range of 32.5 wt% to 10 wt%. It was an effective measurement of urea concentration to use the electrical conductivity sensor in the temperature range of $-10{\sim}22^{\circ}C$ and to use the ultrasonic sensor at $22^{\circ}C$ or more. Simultaneous measurement of concentration, liquid-level and temperature of the urea tank will be possible by attaching the electrical conductivity sensor and the ultrasonic sensor (split-type) to one sensor together.

Phenol/formaldehyde-derived macroporous carbon foams prepared with aprotic ionic liquid as liquid template

  • Byun, Hae-Bong;Nam, Gi-Min;Rhym, Young-Mok;Shim, Sang-Eun
    • Carbon letters
    • /
    • v.13 no.2
    • /
    • pp.94-98
    • /
    • 2012
  • Herein, macroporous carbon foams were successfully prepared with phenol and formaldehyde as carbon precursors and an ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ($BMIPF_6$), as a pore generator by employing a polymerization-induced phase separation method. During the polycondensation reaction of phenol and formaldehyde, $BMIPF_6$ forms a clustered structure which in turn yields macropores upon carbonization. The morphology, pore structure, electrical conductivity of carbon foams were investigated in terms of the amount of the ionic liquid. The as-prepared macroporous carbon foams had around 100-150 ${\mu}m$-sized pores. More importantly, the electrical conductivity of the carbon foams was linearly improved by the addition of $BMIPF_6$. To the best of the author's knowledge, this is the first result reporting the possibility of the use of an ionic liquid to prepare porous carbon materials.

Fabrication of ionic liquid and polymer based solid-state electrolyte for secondary battery (이온성 액체와 고분자 기반의 이차전지용 고체 전해질의 제조)

  • Kang, Hye Ju;Jeong, Hyeon Taek
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1591-1596
    • /
    • 2020
  • The solid-state electrolyte based on polymer has great attention to develop its ionic conductivity from conventional polymer electrolyte by using wide range of ionic liquids with remarkable processability, flexibility and is applicable to various electrochemical devices including batteries, supercapacitor. Polymer electrolyte based on Ionic liquid with high conductivity, wide electrochemical stability, thermal stability is used in various electronic devices. In this work, we have investigated and developed solid-state electrolyte based on ionic liquid and polymer with enhanced ionic conductivity and electrochemical performances to conduct to various electronic devices including secondary battery. The ionic conductivity of polymer based solid state electrolyte with optimized ratio of the ionic liquid was 1.46-2 S/cm. The ionic liquid and polymer based electrolyte with enhanced ionic conductivity is promising candidates to utilize in wide range of secondary batteries.

Characterization of Ionic Liquid Contained Polymer Gel Electrolyte (이온성 액체를 함유한 고분자 겔 전해질의 특성연구)

  • Ryu, Sang-Woog;Song, Eui-Hwan
    • Polymer(Korea)
    • /
    • v.32 no.1
    • /
    • pp.85-89
    • /
    • 2008
  • Acrylate polymer gel electrolytes containing N-methoxymethyl-N-methylpyrrolidium bis (trifluoro - methansulfonyl) imide (MPSI) as an ionic liquid were synthesized by solution polymerization in the presence of carbonate solvent. ionic conductivity and mechanical properties of the polymer gel electrolytes were investigated by impedance analyzer and universal testing machine as a function of the amount of polymer, and ionic liquid and type of crosslinker. The maximum ionic conductivity of polymer gel electrolytes was 0.8 mS/cm at $25^{\circ}C$ with 15 wt% of polymer, 30 wt% of ionic liquid and 5 wt% of crosslinker. The mechanical analysis showed that the tensile strength of polymer gel electrolytes increased with additional polymer contents and had the maximum value of 0.5 MPa with a reasonable ionic conductivity.

Electrochemical Characterization of Lithium Polyelectrolyte Based on Ionic Liquid

  • Cha, E.-H.;Lim, S.-A.;Kim, D.-W.;Choi, N.-S.
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.3
    • /
    • pp.271-275
    • /
    • 2009
  • Five novel lithium polyelectrolyte-ionic liquid systems, using poly (lithium 2-acrylamido-2-methyl propanesulfonate; PAMPSLi) were prepared and their electrochemical properties were measured. The ionic conductivity of the PAMPSLi/1-ethyl-3-methylimidazolium tricyano methanide (emImTCM) system was exhibited high conductivity (1.28 $\times$ $10^{-3}$ $S/cm^{-1}$). The high conductivity and low viscosity of PAMPSLi/emImTCM system is due to the high flexibility of imidazolium cation and dissociation of lithium cation from the polymer chains. The PAMPSLi/N,N-dimethyl-N-propyl-Nbutylammonium tricyanomethanide ($N_{1134}TCM$) and PAMPSLi/N, N-dimethyl-N-propyl-N-butylammonium dicyanamide ($N_{1134}DCA$) systems showed fairly high conductivity (6.3 $\times$ $10^{-4}$ $S/cm^{-1}$, 6.0 $\times$ 10.4 S/cm.1). PAMPSLi/Trihexyl (tetradecyl) phosphonium bis (trifluoromethane sulfonyl) amide ($P_{66614}TFSA$) exhibited low conductivity (2.22 $\times$ $10^{-5}$ $Scm^{-1}$) and thermally stable over 400$^{\circ}C$.

Molecular Dynamics Simulation Study of the Transport Properties of Liquid Argon: The Green-Kubo Formula Revisited

  • Lee, Song-Hi
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.8
    • /
    • pp.1371-1374
    • /
    • 2007
  • The velocity auto-correlation (VAC) function of liquid argon in the Green-Kubo formula decays quickly within 5 ps to give a well-defined diffusion coefficient because the velocity is the property of each individual particle, whereas the stress (SAC) and heat-flux auto-correlation (HFAC) functions for shear viscosity and thermal conductivity have non-decaying, long-time tails because the stress and heat-flux appear as system properties. This problem can be overcome through N (number of particles)-fold improvement in the statistical accuracy, by considering the stress and the heat-flux of the system as properties of each particle and by deriving new Green-Kubo formulas for shear viscosity and thermal conductivity. The results obtained for the transport coefficients of liquid argon obtained are discussed.

Measurement of liquid film thickness distribution on sprayed surfaces (스프레이가 분사되는 표면에서의 액막 두께 분포 측정)

  • Tae Ho Kim;Myung Ho Kim;Hyoung Kyu Cho;Byoung Jae Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.3
    • /
    • pp.33-38
    • /
    • 2023
  • Spray cooling is a method of cooling high-temperature heating elements by spraying droplets. Recently, spray cooling has been proposed for use in next-generation nuclear reactors. When droplets are sprayed onto the outer wall of a heat exchanger tube, a film boiling occurs on the outer wall. Over time, the outer wall temperature decreases, and a liquid film forms on the outer wall, and the heat exchanger outer wall is subsequently cooled by the liquid film. In this case, the liquid film thickness has a great influence on the heat removal performance. In this study, an experimental study was conducted to measure the liquid film thickness distribution in a droplet spray environment. For this purpose, a method using the electrical conductivity of the liquid was adopted.