• Title/Summary/Keyword: Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Search Result 292, Processing Time 0.03 seconds

Quantitative measurement of salivary testosterone in Korean adults by stable isotope-dilution liquid chromatographyelectrospray-tandem mass spectrometry

  • Lee, Sang-Hoo;Kwon, Soon-Ho;Shin, Hye-Jin;Park, Ji-Myeong;Lim, Hwan-Sub;Lee, Kyoung-Ryul;Kim, Young-Jin
    • BMB Reports
    • /
    • v.43 no.11
    • /
    • pp.761-765
    • /
    • 2010
  • Salivary testosterone levels in Korean adults were quantitatively measured for the first time by liquid chromatography-electrospray-tandem mass spectrometry (LC ESI MS/MS). Salivary testosterone was separated on a multiple reaction monitoring (MRM) chromatogram within 7 min. The LC ESI MS/MS assay was validated over the linearity range of 0.01-2.00 ng/ml (r=0.99987) using testosterone-$d_3$ as an internal standard. The lower limit of quantification (LOQ) was 0.01 ng/ml. The intra- and inter-assay precisions were 1.54% to 4.09% and 0.96% to 4.29%, respectively. The mean recovery was 93.32% (range 88.43-98.05%). The validated assay was then applied to measure the salivary testosterone levels of Korean adults. In men, the salivary testosterone level collected between 9:00-11:00 am was approximately 2.8 times higher than that in women (P < 0.0001). Salivary testosterone levels in both sexes negatively correlated with age. The present assay would also be useful in measuring salivary testosterone levels in clinical laboratories.

Rapid Quantitative Analysis of Vancomycin in Human Plasma and Urine Using LC-MS/MS (LC - MS/MS를 이용한 혈장과 뇨중에서 Vancomycin의 빠른정량분석)

  • Kim, Hohyun;Roh, Hyeongjin;Han, Sang-Beom
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.410-416
    • /
    • 2002
  • In this study, a new quantitative analytical method has been developed for the rapid determination of vancomycin in human plasma and urine using liquid chromatography/tandem mass spectrometry (LC - MS/MS). Chromatography was carried out on a $C_{18}$ XTerra MS column ($2.1{\times}30mm$) with a particle size of $3.5{\mu}m$. The mobile phase was 0.25% formic acid in 10% acetonitrile and the flow rate was $250{\mu}L/min$. Vancomycin and caffeine (internal standard) were detected by MS/MS using multiple reaction monitoring (MRM). Vancomycin gives a predominant doubly protonated precursor molecule ($[M+2H]^{2+}$) at m/z 725.0 and a corresponding product ion of m/z 100.0. Detection of vancomycin was good, accurate and precise, with a limit of detection of 1 nM in plasma. The calibration curves for vancomycin in human plasma was linear in a concentration range of $0.01{\mu}M$ - $100{\mu}M$ for plasma. This method has been successfully applied to determine the concentration of vancomycin in human plasma and urine from pharmacokinetic study and relative studies.

Paralytic Shellfish Poisoning (PSP) Analysis using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS를 이용한 마비성패류독소 분석조건 검토)

  • Song, Ki Cheol;Lee, Ka Jeong;Yu, Hong Sik;Mok, Jong Soo;Kim, Ji Hoe;Lim, Keun Sik;Lee, Mi Ae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.46 no.2
    • /
    • pp.154-159
    • /
    • 2013
  • The AOAC Mouse Bioassay method (MBA) has been widely used for routine monitoring of paralytic shellfish poisoning (PSP) for more than 50 years. However, this method has low sensitivity and experiences interference from other components in the extract. Also, ethical issues have been raised against the continued use of this live-mouse assay. To establish an alternative method for PSP analysis, we attempted to develop PSP analysis conditions using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The LC-MS/MS analysis of reference material showed very reasonable accuracy, and the analysis time was just 15 min. However, the recovery rate of toxin spike samples using the LC-MS/MS analysis was 59.4-91.0%. We also attempted to remove the matrix effect using shellfish extracts, but recoveries of C1 and C2 did not improve. A comparison between the results of MBA and LC-MS/MS analysis revealed good correlations, with values of 0.8878 and 0.9211 for oyster and mussel matrices, respectively.

Simultaneous Quantitative Determination of Nine Hallucinogenic NBOMe Derivatives in Human Plasma Using Liquid Chromatography Tandem Mass Spectrometry

  • Seo, Hyewon;Yoo, Hye Hyun;Kim, Young-Hoon;Hong, Jin;Sheen, Yhun Yhong
    • Mass Spectrometry Letters
    • /
    • v.10 no.1
    • /
    • pp.18-26
    • /
    • 2019
  • We developed a bioanalytical method for simultaneous determination of nine NBOMe derivatives (25H-NBOMe, 25B-NBOMe, 25E-NBOMe, 25N-NBOMe, 25C-NBOH, 25I-NBOH, 25B-NBF, 25C-NBF, and 25I-NBF) in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS). Human plasma samples were pre-treated using solid-phase extraction. Separation was achieved on a C18 column under gradient elution using a mobile phase containing 0.1% formic acid in acetonitrile and 0.1% formic acid in water at a flow rate of 0.3 mL/min. Mass detection was performed in the positive ion mode using multiple reaction monitoring. The calibration range was 1-100 ng/mL for all quantitative analytes, with a correlation coefficient greater than 0.99. The intra- and inter-day precision and accuracy varied from 0.85 to 6.92% and from 90.19 to 108.69%, respectively. The recovery ranged from 86.36 to 118.52%, and the matrix effects ranged from 27.09 to 99.72%. The stability was acceptable in various conditions. The LC-MS/MS method was validated for linearity, accuracy, precision, matrix effects, recovery and stability in accordance with the FDA guidance. The proposed method is suitable for reliable and robust routine screening and analysis of nine NBOMe derivatives in forensic field.

Rapid Quantification of Topotecan in Biological Samples by Liquid Chromatography/Tandem Mass Spectrometry

  • Shin, Beom-Soo;Lee, Mann-Hyung;Yoo, Sun-Dong
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.5
    • /
    • pp.367-372
    • /
    • 2009
  • A rapid liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay method was developed for the determination of topotecan levels in rat serum. The assay utilized a single liquid-liquid extraction with a mixture of ethy l acetate and acetonitrile (6:1 v/v) and isocratic elution. The multiple reaction monitoring was based on the transition of m/z 422.0$\rightarrow$376.5 for topotecan and 315.1$\rightarrow$226.6 for clomipramine (internal standard). The developed assay was validated to demonstrate the specificity, recovery, lower limit of quantification (LLOQ), accuracy and precision. The assay was linear over a concentration range from 0.5-100 ng/mL, with LLOQ being 0.5 ng/mL using a small volume of rat serum (0.1 mL). The mean intra- and inter-day assay accuracy was 87.7-111.0% and 97.8-108.3, respectively, and the mean intra- and interday precision was between 1.6-4.3% and 3.8-10.3, respectively. The developed assay was applied to a pharmacokinetic study after a bolus i.v. injection of topotecan in rats.

Simultaneous Determination of Ultra-Trace Pesticides and Synthetic Materials in Surface Water by LC-ESI-MS/MS (하천수에서 LC-ESI-MS/MS에 의한 극미량 농약류 및 합성원료의 동시분석법)

  • Hong, Seon-Haw;Lee, Jun-Bae;Lee, Soo-Hyung;Cho, Young-Hwan;Shin, Ho-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.3
    • /
    • pp.225-232
    • /
    • 2015
  • A liquid chromatography-electrospray ionization-tandem mass spectrometry method (LC-ESI-MS/MS) was used for determining seven pesticides (2,4-dichlorophenoxyacetic acid, methomyl, aldicarb, 2-methyl- 4-chlorophenoxy- acetic acid, molinate, carbaryl and carbofuran) and two synthetic materials (quinoline and bisphenol-A) in surface water. The analytes were extracted using solid-phase extraction (SPE). The eluate was concentrated by nitrogen gas. 100 microliters of 30% (v/v) methanol aqueous solution were used to dissolve the residue and an aliquot of the reconstituted solution was directly injected into LC-ESI-MS/MS after the filtration using 0.2 μm polytetrafluoroethylene (PTFE) syringe filter. Under the established condition, the calibration curves of the analytes were linear with correlation coefficients of above 0.997. The quantification limit was 0.002~0.011 μg/L and the relative standard deviations were less than 16.4%. In addition, accuracy was in the range of 84~107% and the recoveries were values between 56.2 and 98.6%. In this study, the developed method was applied to the analysis of real surface water samples.

Mass Spectrometry-Based Analytical Methods of Amatoxins in Biological Fluids to Monitor Amatoxin-Induced Mushroom Poisoning

  • Choi, Jin-Sung;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.95-105
    • /
    • 2022
  • Amatoxin-induced mushroom poisoning starts with nonspecific symptoms of toxicity but hepatic damage may follow, resulting in the rapid development of liver insufficiency and, ultimately, coma and death. Accurate detection of amatoxins, such as α-, β-, and γ-amanitin, within the first few hours after presentation is necessary to improve the therapeutic outcomes of patients. Therefore, analytical methods for the identification and quantification of α-, β-, and γ-amanitin in biological samples are necessary for clinical and forensic toxicology. This study presents a literature review of the analytical techniques available for amatoxin detection in biological matrices, and established an inventory of liquid chromatography (LC) techniques with mass spectrometry (MS), ultraviolet (UV) detection, and electrochemical detection (ECD). LC-MS methods using quadrupole tandem mass spectrometry, time-of-flight mass spectrometry, and orbitrap MS are powerful analytical techniques for the identification and determination of amatoxins in plasma, urine, serum, and tissue samples, with high sensitivity, specificity, and reproducibility compared to LC with UV and ECD, enzyme-linked immunoassay, and capillary electrophoresis methods.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips

  • Park, Sun-Young;Kim, Byung-Joo;So, Hun-Young;Kim, Yeong-Joon;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.737-744
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with 13C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and an Oasis mixed-phase cation exchange (MCX) SPE cartridge. The extract was analyzed by using LC/ESI/Tandem MS in positive ion mode. LC with a medium reversed-phase (C4) column was optimized to obtain adequate chromatographic retention and separation of acrylamide. MS was operated to selectively monitor [M+H]+ ions of the analyte and its isotope analogue at m/z 72 and m/z 75, respectively. Sample was also analyzed by the LC/MS with selectively monitoring the collisionally induced dissociation channels of m/z 72 → m/z 55 and m/z 75 → 58. Compared to the LC/MS chromatograms, the LC/MS/MS chromatograms showed substantially reduced background chemical noises coming from solvent clusters formed during ESI spray processes and interferences from sample matrix. Repeatability and reproducibility studies showed that the LC/MS/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0% while the LC/MS results are influenced by chemical interferences.

Sensitive determination of pendimethalin and dinoseb in environmental water by ultra performance liquid chromatography-tandem mass spectrometry

  • Lim, Hyun-Hee;Park, Tae-Jin;Lee, Soo-Hyung;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.194-204
    • /
    • 2017
  • Direct injection (DI) and solid phase extraction (SPE) methods for the simultaneous determination of pendimethalin (PDM) and dinoseb (DNS) in environmental water have been optimized using the ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. The limits of quantification (LOQs) of PDM and DNS were $0.01{\mu}g/L$ using the DI method and $0.0001-0.0002{\mu}g/L$ using the SPE method. The precision by SPE UPLC-MS/MS was less than 11 % for intra-day and inter-day analyses. When the proposed SPE method was used to analyze two analytes in environmental water, PDM was detected in a concentration range of $0.0002-0.011{\mu}g/L$ in 31 samples of the 114 surface water samples, and DNS was detected in a concentration range of $0.0005-0.045{\mu}g/L$ in 17 samples of the 114 surface water samples analyzed. When the DI method was used to analyze target compounds in the same samples, the detected concentrations of the two analytes were within 21% in samples with concentrations above $0.01{\mu}g/L$. The DI UPLC-MS/MS method can thus be used for the routine monitoring of PDM and DNS in environmental water, and the SPE LC-MS/MS method can be used for the determination of the ultra-trace PDM and DNS residues in environmental water.