• Title/Summary/Keyword: Ling light

Search Result 25, Processing Time 0.028 seconds

Visuality and Hapticity in Acupoints: A Study on Benshu Chapter in Huangdi Neijng Lingshu (경혈의 시각성과 촉각성: 『영추·본수』의 한 연구)

  • Song, Seok Mo
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.290-307
    • /
    • 2021
  • Objectives : Perceptual experiences have a causal relationship with reality. If there exists something corresponding to acupoints, there should be perceptual experiences for that something. The purpose of this study is to identify and to analyze the perceptual experiences for acupoints within 『LingShu·BenShu』. Methods : First, we briefly propose a perceptual anatomy in order to describe the perceived human body parts, and their perceived directions and places. Second, we analyze the ways of identifying acupoints in the original text of 『LingShu·BenShu』. Results : From 『LingShu·BenShu』, the procedures of identifying total 64 acupoints were recognized. It was clarified that they are by way of visual and haptic explorations in body regions and partial regions. Conclusions : Perceptual explorations for acupoints follow three major principles: of gradual narrowing down, of determination of direction or place, of relative distance. At the final stages, categories of form and location are encountered by observers. The forms have either concavities or convexities. They are determinate indicators of where acupoints are, while the locations are indetermanate. Haptic forms of acupoints are newly discovered from textual analysis with perceptual anatomy. These properties will shed new light both on study of acupoints and on study of meridians.

Development of Ring Right for Medical Purpose (메디컬 링 라이트의 개발)

  • Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.766-767
    • /
    • 2010
  • By using LED which is a light source which has been in the spotlight recently, the ring light for medical purposes was developed for shadowless shooting of local site in the affected area. The developed ring light was designed to be able to control the various quantity of light by using PWM (pulse width modulation) method, and by controlling each LED (light emitting diode) independently the regulation of color temperature and color rendering are possible. Also, the persistent light for continuous shooting of affected area and flash mode action for snap shooting are possible. In this study the response speed of momentary flash function was checked using interface circuit configured for momentary shadowless shooting of affected area.

  • PDF

Analyses on the Pricing Factors from a Case Study of Light Trucks

  • Ling, Feng;Ojima, Yoshikazu;Suzuki, Tomomichi
    • International Journal of Quality Innovation
    • /
    • v.6 no.1
    • /
    • pp.35-42
    • /
    • 2005
  • The purpose of this paper is to clarify analytically the relation between the characteristics and the pricing of the products of individual manufacturers, so we can offer beneficial information for designing and developing products. Light trucks of 1 ton to 4 ton have been taken up as examples. We carried out analyses based on the information on the evaluations of the functional characteristics by surveying the specifications obtained from light truck catalogues.

Double clad fiber probe for fluorescence spectroscopy

  • Wang, Ling;Lee, Byeong-Ha
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.35-36
    • /
    • 2007
  • We report a probe using a single double clad fiber (DCF) for fluorescence spectroscopy. Bidirectional separate transmission for excitation and fluorescence light in a single fiber was implemented. A DCF coupler made by side-polished method could extract none but the collected fluorescence signals propagating in inner cladding mode, thereby diminishing the interference of silica background generated by the excitation in core mode. The experimental results show that the fluorescence spectra of biological tissues obtained using the DCF probes have much less silica background than using a standard multiple-mode fiber.

  • PDF

Quality Enhancement of a Complex Holographic Display Using a Single Spatial Light Modulator and a Circular Grating

  • Bang, Le Thanh;Piao, Yan Ling;Kim, Jong Jae;Kim, Nam
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.70-77
    • /
    • 2016
  • This paper proposes an optical system for complex holographic display that enhances the quality of the reconstructed three-dimensional image. This work focuses on a new design for an optical system and the evaluation of the complex holographic display, using a single spatial light modulator (SLM) and a circular grating. The optical system is based on a 4-f system in which the imaginary and real information of the hologram is displayed on concentric rectangular areas of the SLM and circular grating. Thus, this method overcomes the lack of accuracy in the pixel positions between two window holograms in previous studies, and achieves a higher intensity of the real object points of the reconstructed hologram than the original phase-reconstructed hologram. The proposed method provides approximately 30% less NMRS (Normal Root Mean Square) error, compared to previous systems, which is verified by both simulation and optical experiment.

Genome Architecture and Its Roles in Human Copy Number Variation

  • Chen, Lu;Zhou, Weichen;Zhang, Ling;Zhang, Feng
    • Genomics & Informatics
    • /
    • v.12 no.4
    • /
    • pp.136-144
    • /
    • 2014
  • Besides single-nucleotide variants in the human genome, large-scale genomic variants, such as copy number variations (CNVs), are being increasingly discovered as a genetic source of human diversity and the pathogenic factors of diseases. Recent experimental findings have shed light on the links between different genome architectures and CNV mutagenesis. In this review, we summarize various genomic features and discuss their contributions to CNV formation. Genomic repeats, including both low-copy and high-copy repeats, play important roles in CNV instability, which was initially known as DNA recombination events. Furthermore, it has been found that human genomic repeats can also induce DNA replication errors and consequently result in CNV mutations. Some recent studies showed that DNA replication timing, which reflects the high-order information of genomic organization, is involved in human CNV mutations. Our review highlights that genome architecture, from DNA sequence to high-order genomic organization, is an important molecular factor in CNV mutagenesis and human genomic instability.

Sizing Efficiency of AKD in Causticizing Calcium Carbonate Filled Paper

  • Wang, Jian;Liu, Ling;Xu, Yong-Jian
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.2
    • /
    • pp.1-7
    • /
    • 2014
  • Causticizing calcium carbonate (CCC) is produced as a by-product in the causticization step of the kraft pulping process. It is often calcined in a rotary lime kiln after being dewatered and reused in the causticizing process. But for the China mill, the conventional recycled way is difficult because the CCC is mainly obtained from non-wood pulping materials, which higher silicon content led to serious silicon obstacle. So it is often discarded as solid waste or used in landfill after dewatering and secondary pollution is brought. In order to prevent its secondary pollution, recent years, the CCC is used as a filler in China papermaking industry. In mill trials, the CCC can be used to replace an amount of precipitated calcium carbonate (PCC). Unfortunately, the application scope and dosage of CCC have been limited due to its lower sizing efficiency than PCC. In this study, the reason for the lower sizing efficiency of alkyl ketene dimer (AKD) when CCC was used as a filler was investigated. The results showed that the materials in green liquid, such as insoluble matter in green liquid, silicon and metal ions, were a little influence on the sizing efficiency of AKD. The higher BET and BJH pore volume of the CCC were the main reason for lower sizing efficiency of AKD when it was used as filler.

A Study on the Development of Photoelastic Experimental Hybrid Method for Color Isochromatics (칼라 등색선무늬용 광탄성실험 하이브릿법 개발에 관한연구)

  • Kwon, O-Sung;Hawong, Jai-Sug;Nam, Jeong-Hwan;Han, Song-Ling;Kwon, Gun;Liu, Yi
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.66-71
    • /
    • 2007
  • Isochromatics obtained from photoelastic experiment shows the stress distributions of full field of a structure under a load. Therefore stress distributions of the structure can be read at a glace through isochromatics. Many experimental data are obtained from isochromatics. And then, the various photoelastic experimental hybrid methods have been developed. Until now, monochromatic light has been used for photoelastic experimental hybrid method. Therefore the photoelastic experimental hybrid method used until now is called the photoelastic experimental hybrid method for black and white isochromatics. When stresses are analyed by photoelastic experimental hybrid method, many experimental data are needed. Therefore some fringe orders of isochromatics are needed for the photoelastic experimental hybrid method for white and black isochromatics. Therefore in this paper, the photoelastic experimental hybrid method for color isochromatics is developed. In this case, two fringe orders are enough for the experimental data of photoelastic experimental hybrid method for color isochromatics. Applying the method to stress concentration problems, its validity is confirmed. In the precision, the photoelastic experimental hybrid method for color isochromatics is better than the photoelastic experimental hybrid method for white and black isochromatics when fringe orders of isochromatics are few. When fringe orders are few, the photoelastic experimental hybrid method for color isochromatics can be used to analyze stress through few fringe orders of isochromatics.

  • PDF

Optimum Design of Ring Light for Medical Purpose using High Brightness LED (고휘도 LED 를 이용한 의료용 링 라이트의 최적 설계)

  • Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.757-758
    • /
    • 2010
  • At the time of medical treatment and surgical operation, halogen lamp and plasma lamp were mainly used as luminous source for lighting. These two luminous sources have drawbacks that the life of lamps are not long, various problems are brought about due to excessive heat generation and its volume is very big because of cooling device. Accordingly, in this research a ring light was developed so that a partial shadowless shooting for the patient's affected area at the medical treatment room and surgical operation room using high luminance LED for which attention is being paid as new lighting parts for medical purpose. LED which was applied to the development used high luminance three color LED for full color for which various color materialization and the adjustment of radiation intensity are possible and we can get white light in order to emphasize the delicate expression for generic tone of shooting object, strong highlight, simple shadow and three dimensional effect at the time of close-up shadowless shooting of the affected area.

  • PDF