• Title/Summary/Keyword: Lines

Search Result 13,735, Processing Time 0.038 seconds

Calculation of Magnetic Fields under 3 Phase Power Lines with Branch Lines (분기선로가 있는 3상 전력선로하의 전자파 자계 계산)

  • Kang, Dae-Ho;Lee, Yong-Sik;Kim, Bu-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.110-119
    • /
    • 2009
  • In this study magnetic fields near electric power lines with branch lines which have a arbitrary angle were derived and formulated by dipole antenna theory and could be calculated easily using the formula. It seems that those formula could be applicable to the consideration of magnetic fields during the design of distribution lines with branch lines. As an example those formulated equations on elements of magnetic fields were applied to a model of 3 phase distribution lines with branch lines and calculated by Matlab programs and the results were presented The analyzed results are follows. The resultant magnetic field is dominated by the componant By all over y-axis in the case of the smaller branched angle $\alpha$ and the lower observed point z. In case of ${\alpha}=\frac{\pi}{2}$[rad], the resultant field is affected by the componant Bx. The resultant field is dominated by the componant Bz at the vicinity of the power lines and it shows very large value at the branch line position of y-axis in case of ${\alpha}>\frac{\pi}{2}$.

A Low Power ROM using Charge Recycling and Charge Sharing (전하 재활용과 전하 공유를 이용한 저전력 롬)

  • 양병도;김이섭
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.7
    • /
    • pp.532-541
    • /
    • 2003
  • In a memory, most power is dissipated in high capacitive lines such as predecoder lines, word lines, and bit lines. To reduce the power dissipation in these high capacitive lines, this paper proposes three techniques using charge recycling and charge sharing. One is the charge recycling predecoder (CRPD). The second one is the charge recycling word line decoder (CRWD). The last one is the charge sharing bit line (CSBL) for a ROM. The CRPD and the CRWD recycle the previously used charge in predecoder lines and word lines. Theoretically, the power consumption in predecoder lines and word lines are reduced to a half. The CSBL reduces the swing voltage in the ROM bit lines to very small voltage using a charge sharing technique. the CSBL can significantly reduce the power dissipation in ROM bit lines. The CRPD, the CRWD, and the CSBL consume 82%, 72%, and 64% of the power of previous ROM designs respectively. A charge recycling and charge sharing ROM (CRCS-ROM) with the CRPD, the CRWD, and the CSBL is implemented. A CRCS-ROM with 8K16bits was fabricated in a 0.3${\mu}{\textrm}{m}$ CMOS process. The CRCS-ROM consumes 8.63㎽ at 100MHz with 3.3V. The chip core area is 0.1 $\textrm{mm}^2$.

Selection of Short Stem Astragalus membranaceus Lines by Assessing Agronomic Characteristics and Biological Activity (농업형질 및 생리활성 평가를 통한 황기 단간 계통 선발)

  • Lee, Sang Hoon;Koo, Sung Cheol;Han, Jong Won;Lee, Woo Moon;Hur, Mok
    • Korean Journal of Medicinal Crop Science
    • /
    • v.26 no.6
    • /
    • pp.471-476
    • /
    • 2018
  • Background: Astragalus membranaceus belonging to the Leguminosae family is often utilized as a traditional medicine. The aim of this study was to elucidate the basic breeding information required to develop short stem A. membranaceus cultivars. Methods and Results: Roots of A. membranaceus advanced yield trial (AYT) lines were harvested in late October 2017. Root yield of six AYT lines were increased in a range of 8.9 - 74.8% compared with 'Aseong' as control (check variety). The height of seven AYT lines were shorter than that of 'Aseong'. In addition, stem diameter of nine AYT lines was thicker than that of 'Aseong'. Consequently, 1502-56, 1503-90, and 1510-80 were selected as elite lines for the development of short stem cultivars. HPLC analysis was perfromed to identify lines with high level active components such as calycosin-7-O-${\beta}$-D-glucoside and calycosin. The levels of both active components were higher in 1502-56, and 1503-90, but not in 1510-80 compared to 'Aseong'. In addition, 2,2-Diphenyl-1-picryl hydrazyl (DPPH) radical scavenging activity was higher in the 1502-56 compared to 'Aseong'. Considering these results, two AYT lines, 1502-56 and 1503-90 were selected as short stem lines with high calycosin-7-O-${\beta}$-D-glucoside and calycosin content. Conclusions: Taken together, Two short stem lines were identified in this study. In our future study, regional yield trial (RYT) will be conducted using these selected lines to develop new cultivars.

Calculation of an Induced Voltage on Telecommunication Lines in Parallel Distribution Lines (병행 배전선로에서의 통신선 유도전압 계산)

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Seong-Heon;Kim, Seong-Arm;Weon, Bong-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1688-1695
    • /
    • 2008
  • Recently, it is common in a distribution system of Korea Electric Power Corporation (KEPCO) to find instances where distribution lines are parallel. A traditional method of an induced voltage calculation is not suitable for parallel distribution lines. For more actual analysis of induced voltage on telecommunication lines in parallel distribution lines, a new calculation method is needed. This paper presents a new calculation method of an induced voltage on telecommunication line using equivalent ${\pi}$ circuits matrix in parallel distribution lines. The advantages of the calculation method are using actual neutral current value and not using screening factor for considering the overhead ground wire and the neutral wire. To verify the effectiveness and the accuracy of the method, various case studies are performed with EMTP(Electro-Magnetic Transients Program).

Stability Analysis of Mooring Lines of a Submersible Fish Cage System Using Numerical Model

  • Kim, Tae-Ho;Hwang, Kyu-Serk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.690-699
    • /
    • 2011
  • A numerical model analysis was performed to analyze the stability of the mooring lines of an automatic submersible fish cage system in waves and currents. The fish cage system consisted of a 12-angled rigid frame, net cage, cover net, 12 upper floats, 12 tanks(for fixed and variable ballast), mooring lines, anchors, and a control station. Simulations were performed with the cage at the surface of the water and at a depth of 20 m. A Morison equation type model was used for simulations of the system in two configurations. The force parameters described both regular and random waves, with and without currents, and their values were input to the model. Mooring tension calculations were conducted on the mooring lines, grid lines and lower bridle lines of the cage. The stability of the mooring lines was checked under both static and dynamic conditions.

Map recognition using the relation between line segments (선분들간의 관계를 이용한 인식)

  • 장경식;김재희
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.10
    • /
    • pp.89-97
    • /
    • 1997
  • Because a map consists of many lines, a process of recognizing an object in a map is one to group lines that are consistent with the structure of the object. Therefore, it is important to establish an efficient method for finding lines which constitute objects. In this paper, a novel method for recognizing roads and districts in a land register map is proposed. In this method, lines that constitute objects are searched in a reduced search space by defining some relations between lines, and objects are recognized by using the structural information of the objects. As a result, the search space is reduced effetively, and even objects that embody the broken lines and the crossed lines are recognized.

  • PDF

A Study on Teaching How to Draw Auxiliary Lines in Geometry Proof (보조선 지도법 연구)

  • Yim, Jae-Hoon;Park, Kyung-Mee
    • School Mathematics
    • /
    • v.4 no.1
    • /
    • pp.1-13
    • /
    • 2002
  • The purpose of this study is to investigate the reasons and backgrounds of drawing auxiliary lines in the proof of geometry. In most of proofs in geometry, drawing auxiliary lines provide important clues, thus they play a key role in deductive proof. However, many student tend to have difficulties of drawing auxiliary lines because there seems to be no general rule to produce auxiliary lines. To alleviate such difficulties, informal activities need to be encouraged prior to draw auxiliary lines in rigorous deductive proof. Informal activities are considered to be contrasting to deductive proof, but at the same time they are connected to deductive proof because each in formal activity can be mathematically represented. For example, the informal activities such as fliping and superimposing can be mathematically translated into bisecting line and congruence. To elaborate this idea, some examples from the middle school mathematics were chosen to corroborate the relation between informal activities and deductive proof. This attempt could be a stepping stone to the discussion of how to teach auxiliary lines and deductive reasoning.

  • PDF

A Protection Technique Against the Damages Caused by Lightning Surges on Information and Communication Facilities

  • Lee, Bok-Hee;Kang, Sung-Man;Ahn, Chang-Hwan
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.4
    • /
    • pp.117-122
    • /
    • 2003
  • The AC power lines and signal lines of info-communication networks are routed on overhead poles and are highly exposed to lightning strikes. Due to the potential difference between grounding points of AC power lines and signal lines, the electronic equipments connected to the signal lines can easily be damaged by lightning surges. In this work, in order to develop reliable methods of protecting information and communication facilities from lightning surges, the reliability and performance of SPDs (surge protective devices) were experimentally investigated in an actual-sized test circuit. The behaviors of SPDs against lightning surges from AC power lines and signal lines and the coordinated effects of SPD installation methods were evaluated. As a consequence, it was confirmed that the bypass arrester methods and common grounding system are both highly effective.

A STUDY OF DETERMINATION PRIORITY ORDER FOR BUILDING RAILROADS IN METROPOLITAN AREA (광역철도건설 우선순위에 관한 연구 - 수도권전철을 중심으로 -)

  • 이용상
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.137-159
    • /
    • 1998
  • For the construction of railroads in Metropolytan area based upon the outcome of the future demand forecast, a total of 21 lines including electrified double track segment of Ui-Jung-Bu↔Dong-Du-Chun(18.9km) in Kyung-Won Line is expected. Considering the financial difficulties and investment effect of the lines, this in the sequel brings about an important matter of deforming priority Investment plan to build electrified lines among the candidates. In the case of Japan, Tokyo metropolytan area covered In total by 2,070.1km of various lines, i.e., subway lines(241km), private lines(952.7km), JR lines(876.4km), provides convenient means of transportation for the coummuters and makes a contribution to the development of its neighboring areas and to the expansion of settlement areas. Comparing the total length per 1,000$\textrm{km}^2$, Tokyo(105), Paris(117), and London(115) are at least 6 times as large as ours(15). The purpose of this study is two fold provide a basic scheme for building railroads in metropolytan area and determine priority order in accordance with some evaluation criteria.

  • PDF

The Study of Steady-State Interaction Between AC and DC Lines on the Same Transmission Tower (AC 및 DC 송전 선로 병렬 연계에 따른 정상상태 커플링 영향 분석)

  • Yoon, Jong-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1221-1225
    • /
    • 2010
  • The application of the AC and DC lines on the same transmission tower is an economical and practical approaching that increase the power transmission capacity of an existing transmission corridor. But, In this case, Inductive and capacitive coupling between AC and DC lines on the same tower should be investigated in advance. According to the installation plan of 80kV ${\pm}$60MW bipole HVDC in Cheju, KOREA that will be commissioned until 2011, DC lines will parallely operate with 154kV 2 AC lines in existed 154kV AC 4 lines transmission tower. This paper presents the steady state analysis results about the interaction between 154kV AC and 80kV DC lines in the same transmission tower.