• Title/Summary/Keyword: Line scan image

Search Result 182, Processing Time 0.023 seconds

Modified Scan Line Based Generalized Symmetry Transform with Selectively Directional Attention (선택적 방향주의를 가지는 수정된 스캔라인 일반화 대칭 변환)

  • Kim, Dong-Su;Jin, Seong-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.4
    • /
    • pp.411-421
    • /
    • 2001
  • The generalized symmetry transform evaluates symmetry without segmentation and extracts regions of interest in an image by combining locality and reflectional symmetry The demand that the symmetry transform be local is reflected by the distance weight function. When calculating large regions-of-interest, we should select a large standard deviation of distance weight function. But such a large standard deviation makes the execution time increase in the second power of r, which is a radius of search area. In this paper we propose modified scan line based GST with selectively directional attention to improve time complexity The symmetry map of our proposed GST is found to be very similar to that of the existing GST. However the computation time of the proposed GST increases linearly with respect to r because our proposed GST evaluates symmetry between a pair of edge pixels along the scan lines. The GST computation decreases considerably when the proposed GST is peformed with selectively directional attention in case of large r. Several experiments in this paper demonstrate the time efficiency and the usefulness of our proposed GST.

  • PDF

A Study on Graylevel Image Scanning System Realization Using CIS (CIS를 이용한 그레이레벨 이미지 스케닝시스템 구현에 관한 연구)

  • 김영빈;김윤호;류광렬
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.3
    • /
    • pp.470-474
    • /
    • 2002
  • The graylevel image scanning system realization and design using CIS(Contact image Scanning)be amenable to recognize a papers, OMR and OCR sheet is proposed. The design technique is used CIS scanning sensor in fixing step motor and is optimized with DSP processor for inage processing, and transfer input image data par line in feeding a step unit to PC on the USB interfacer. This system is portable ad A4 size scanning. and keeps image scan processing speed 300mm/sec. The recognition percentage has 98% on the OCR and bar codes.

The Effect of PET Scan Time on the Off-Line PET Image Quality in Proton Therapy (양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증)

  • Hong, Gun-Chul;Jang, Joon-Yung;Park, Se-Joon;Cha, Eun-Sun;Lee, Hyuk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.74-79
    • /
    • 2017
  • Purpose Proton therapy can deliver an optimal dose to tumor while reducing unnecessary dose to normal tissue as compared the conventional photon therapy. As proton beams are irradiated into tissue, various positron emitters are produced via nuclear fragmentation reactions. These positron emitters could be used for the dose verification by using PET. However, the short half-life of the radioisotopes makes it hard to obtain the enough amounts of events. The aim of this study is to investigate the effect of off-line PET imaging scan time on the PET image quality. Materials and Methods The various diameters of spheres (D=37, 28, 22 mm) filled with distilled water were inserted in a 2001 IEC body phantom. Then proton beams (100 MU) were irradiated into the center of the each sphere using the wobbling technique with the gantry angle of $0^{\circ}$. The modulation widths of the spread out bragg peak were 16.4, 14.7 and 9.3 cm for the spheres of 37, 28 and 22 mm in diameters respectively. After 5 min of the proton irradiation, the PET images of the IEC body phantom were obtained for 50 min. The PET images with different time courses (0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min) were obtained by dividing the frame with a duration of 10 min. In order to evaluate the off-line PET image quality with the different time courses, the contrast-to-noise ratio (CNR) of the PET image calculated for each sphere. Results The CNRs of the sphere (D=37 mm) were 0.43, 0.42, 0.40, 0.31 and 0.21 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNRs of the sphere (D=28 mm) were 0.36, 0.32, 0.27, 0.19 and 0.09 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNR of 37 mm sphere was decreased rapidly after 30 min of the proton irradiation. In case of the spheres of 28 mm and 22 mm, the CNR was decreased drastically after 20 min of the irradiation. Conclusion The off-line PET imaging time is an important factor for the monitoring of the proton therapy. In case of the lesion diameter of 22 mm, the off-line PET image should be obtained within 25 min after the proton irradiation. When it comes to small size of tumor, the long PET imaging time will be beneficial for the proton therapy treatment monitoring.

  • PDF

Effects of Cutting Direction on the Laser Machining Characteristics of Wood (절삭방향(切削方向)이 목재(木材)의 레이저절삭특성(切削特性)에 미치는 영향(影響))

  • Lee, Hyoung-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.87-92
    • /
    • 1996
  • When cutting 2.0cm-thick red oak and hard maple with an air-jet-assisted carbon-dioxide laser of 2kW output power, maximum feed speed at the point of full penetration of the beam decreased with increasing the angle between grain and cutting direction. Feed speed averaged 3.75 and 3.38 meters per minute for red oak and hard maple, respectively. Gray-level of laser-cut surfaces were analyzed by image analysis system. The highest gray level of laser-cut surface was obtained when red oak was cut parallel to grain by laser. Surface profiler was used to scan the sawn and laser-cut surfaces. Center line average roughnesses of laser-cut surfaces were higher than those of sawn surfaces. Scanning electron micrographs showed the cell walls which were melted by laser.

  • PDF

GENERATION OF AIRBORNE LIDAR INTENSITY IMAGE BY NORMALIZAING RANGE DIFFERENCES

  • Shin, Jung-Il;Yoon, Jong-Suk;Lee, Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.504-507
    • /
    • 2006
  • Airborn Lidar technology has been applied to diverse applications with the advantages of accurate 3D information. Further, Lidar intensity, backscattered signal power, can provid us additional information regarding target's characteristics. Lidar intensity varies by the target reflectance, moisture condition, range, and viewing geometry. This study purposes to generate normalized airborne LiDAR intensity image considering those influential factors such as reflectance, range and geometric/topographic factors (scan angle, ground height, aspect, slope, local incidence angle: LIA). Laser points from one flight line were extracted to simplify the geometric conditions. Laser intensities of sample plots, selected by using a set of reference data and ground survey, werethen statistically analyzed with independent variables. Target reflectance, range between sensor and target, and surface slope were main factors to influence the laser intensity. Intensity of laser points was initially normalized by removing range effect only. However, microsite topographic factor, such as slope angle, was not normalized due to difficulty of automatic calculation.

  • PDF

QUALITY EVALUATION OF TECHNOLOGY OF AGRICULTURAL PRODUCTS

  • Chen, Pictiaw
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.171-190
    • /
    • 1996
  • Quality evaluation of agricultural products has been a subject of interest to many researches for many years. As a results, several nondestructive techniques for quality evaluation of agricultural products have been developed. These methods are based on the detection of various physical properties that correlate well with certain quality factors of the products. This paper presents an overview of various quality evaluation techniques that are based on one of the following properties : density, firmness , vibration characteristic , X-ray and gamma ray transmission, optical reflectance and transmission , electrical properties, aromatic volatile emission, and nuclear magnetic resonance (NMR). The sophistication of nondestructive methods has evolved rapidly with modern technologies. The use of various modern image acquisition techniques, such as solid state TV camera, line-scan camera, X-ray scanning , ultrasonic scanning and NMR imaging, in conjunction with image-processing te hniques has provided new opportunities for researchers to develop many new and improved techniques for nondestructive quality evaluation of agricultural products.

  • PDF

Digital Authentication Technique using Content-based Watermarking in DCT Domain

  • Hyun Lim;Lee, Myung-Eun;Park, Soon-Young;Cho, Wan-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.319-322
    • /
    • 2002
  • In this paper, we present a digital authentication technique using content-based watermarking in digital images. To digest the image contents, Hopfield network is employed on the block-based edge image. The Hopfield function extracts the same tit fur similarly looking blocks so that the values are unlikely to change to the innocuous manipulations while being changed far malicious manipulations. By inputting the extracted bit sequence with secret key to the cryptographic hash function, we generate a watermark for each block by seeding a pseudo random number generator with a hash output Therefore, the proposed authentication technique can distinguish between malicious attacks and innocuous attacks. Watermark embedding is based on the block-based spread spectrum method in DCT domain and the strength of watermark is adjusted according to the local statistics of DCT coefficients in a zig-zag scan line in AC subband. The numerical experiments show that the proposed technique is very efficient in the performance of robust authentication.

  • PDF

Load Distribution Strategies for High Speed Ray-Tracing on Multiprocessors (고속 광선 추적법을 위한 멀티프로세서에서의 부하분산방식)

  • Gwon, O-Bong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.5
    • /
    • pp.1362-1372
    • /
    • 1999
  • Ray-tracing algorithm can synthesize photo-realistic image, but its computational cost is high. Fast image synthesis based on ray-tracing is one of the most important topics in computer graphics. There are two methods for high speed ray-tracing. First this paper discusses various load distribution and scheduling of multiprocessor for high sped ray-tracing. Then this paper proposes load distribution strategies based on them, implements and evaluates it on multiprocessor. The experiment results show that the proposed method can solve the unbalanced load problem of dynamic load distribution, and scan line method and dot method among a kind of static load distribution strategies disperse the load efficiently.

  • PDF

Differentiation of Beef and Fish Meals in Animal Feeds Using Chemometric Analytic Models

  • Yang, Chun-Chieh;Garrido-Novell, Cristobal;Perez-Marin, Dolores;Guerrero-Ginel, Jose E.;Garrido-Varo, Ana;Cho, Hyunjeong;Kim, Moon S.
    • Journal of Biosystems Engineering
    • /
    • v.40 no.2
    • /
    • pp.153-158
    • /
    • 2015
  • Purpose: The research presented in this paper applied the chemometric analysis to the near-infrared spectral data from line-scanned hyperspectral images of beef and fish meals in animal feeds. The chemometric statistical models were developed to distinguish beef meals from fish ones. Methods: The meal samples of 40 fish meals and 15 beef meals were line-scanned to obtain hyperspectral images. The spectral data were retrieved from each of 3600 pixels in the Region of Interest (ROI) of every sample image. The wavebands spanning 969 nm to 1551 nm (across 176 spectral bands) were selected for chemometric analysis. The partial least squares regression (PLSR) and the principal component analysis (PCA) methods of the chemometric analysis were applied to the model development. The purpose of the models was to correctly classify as many beef pixels as possible while misclassified fish pixels in an acceptable amount. Results: The results showed that the success classification rates were 97.9% for beef samples and 99.4% for fish samples by the PLSR model, and 85.1% for beef samples and 88.2% for fish samples by the PCA model. Conclusion: The chemometric analysis-based PLSR and PCA models for the hyperspectral image analysis could differentiate beef meals from fish ones in animal feeds.

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF