• Title/Summary/Keyword: Line Check

Search Result 471, Processing Time 0.034 seconds

Numerical simulation of unsteady galloping of two-dimensional iced transmission line with comparison to conventional quasi-steady analysis

  • Yang, Xiongjun;Lei, Ying;Zhang, Jianguo
    • Structural Engineering and Mechanics
    • /
    • v.75 no.4
    • /
    • pp.487-496
    • /
    • 2020
  • Most of the previous works on numerical analysis of galloping of transmission lines are generally based on the quasisteady theory. However, some wind tunnel tests of the rectangular section or hangers of suspension bridges have shown that the galloping phenomenon has a strong unsteady characteristic and the test results are quite different from the quasi-steady calculation results. Therefore, it is necessary to check the applicability of the quasi-static theory in galloping analysis of the ice-covered transmission line. Although some limited unsteady simulation researches have been conducted on the variation of parameters such as aerodynamic damping, aerodynamic coefficients with wind speed or wind attack angle, there is a need to investigate the numerical simulation of unsteady galloping of two-dimensional iced transmission line with comparison to wind tunnel test results. In this paper, it is proposed to conduct a two dimensional (2-D) unsteady numerical analysis of ice-covered transmission line galloping. First, wind tunnel tests of a typical crescent-shapes iced conductor are conducted firstly to check the subsequent quasisteady and unsteady numerical analysis results. Then, a numerical simulation model consistent with the aeroelastic model in the wind tunnel test is established. The weak coupling methodology is used to consider the fluid-structure interaction in investigating a two-dimension numerical simulation of unsteady galloping of the iced conductor. First, the flow field is simulated to obtain the pressure and velocity distribution of the flow field. The fluid action on the iced conduct at the coupling interface is treated as an external load to the conductor. Then, the movement of the conduct is analyzed separately. The software ANSYS FLUENT is employed and redeveloped to numerically analyze the model responses based on fluid-structure interaction theory. The numerical simulation results of unsteady galloping of the iced conduct are compared with the measured responses of wind tunnel tests and the numerical results by the conventional quasi-steady theory, respectively.

On-line Schedulability Check Algorithm for Imprecise Real-time Tasks (부정확한 실시간태스크들을 위한 온라인 스케쥴가능성 검사 알고리즘)

  • Gi-Hyeon Song
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.9
    • /
    • pp.1167-1176
    • /
    • 2002
  • In a (hard) real-time system, every time-critical task must meet its timing constraint, which is typically specified in terms of its deadline. Many computer systems, such as those for open system environment or multimedia services, need an efficient schedulability test for on-line real-time admission control of new jobs. Although various polynomial time schedulability tests have been proposed, they often fail to decide the schedulability of the system precisely when the system is heavily loaded. Furthermore, the most of previous studies on on-line real-time schedulability tests are concentrated on periodic task applications. Thus, this paper presents an efficient on-line real-time schedulability check algorithm which can be used for imprecise real-time system predictability before dispatching of on-line imprecise real-time task system consisted of aperiodic and preemptive task sets when the system is overloaded.

  • PDF

Construction of Knowledge Base for Fault Tracking Expert System in Semiconductor Production Line (반도체 생산 라인에서의 이탈 처리 추적 전문가 시스템의 지식베이스 구축)

  • 김형종;조대호;이칠기;김훈모;노용한
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • Objective of the research is to put the vast and complex fault tracking knowledge of human experts in semiconductor production line into the knowledge base of computer system. We mined the fault tracking knowledge of domain experts(engineers of production line) for the construction of knowledge base of the expert system. Object oriented fact models which increase the extensibility and reusability have been built. The rules are designed to perform the fault diagnosis of the items in production device. We have exploited the evidence accumulation method to assign check priority in rules. The major contribution is in the overall design and implementation of the nile base and related facts of the expert system in object oriented paradigm for the application of the system in fault diagnosis in semiconductor production line.

  • PDF

The influence that the value suggestion of on-line community members has on the brand affection (온라인 커뮤니티 회원들의 가치제안이 브랜드 애착에 미치는 영향)

  • Han, Kwang-Seok
    • Management & Information Systems Review
    • /
    • v.21
    • /
    • pp.209-237
    • /
    • 2007
  • This research intends to check what value and convenience the on-line brand community members pursue and how such value and convenience affects brand affection. Researching on-line brand community members of ipod, it was found that their value and convenience is composed of 3 types, namely, functional value, emotional value and self-expression value and the concept of brand affection is composed of 3 subsidiary factors, namely, 'love', 'interest' and 'immersion.' Checking how the functional, emotional and self-expression convenience of on-line brand community members affected brand affection, the following result was found. First, functional value and convenience has significant influence on the love affection only at the level of brand affection and has no influence on the relational and immersion affection. Second, self-expression value and convenience has significant influence only on the love affection of brand like functional value and convenience. Third, it was found that emotional value has significant influence on the 3 dimensions of brand affection, namely, love affection, interest affection and immersion affection.

  • PDF

The Performance Evaluation for the Rail Road Train Spring (철도차량용 스프링의 On-Line 성능 평가 방법 연구)

  • 백수곤;박종범;김상봉;하승우;서승후
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.178-185
    • /
    • 2001
  • So many springs in the rail road trains have been degeaded by the long time operation. Specially vibrations makes worse the condition of the springs. The performance evaluation technique for the rail road spring was developed. Using integrated handy tools using hydraulic systems, LVDT, and related software, On-line evaluation is possible to check the system integrity.

  • PDF

Whole Genomic Expression Analysis of Rat Liver Epithelial Cells in Response to Phenytoin

  • Kim, Ji-Hoon;Kim, Seung-Jun;Yeon, Jong-Pil;Yeom, Hye-Jung;Jung, Jin-Wook;Oh, Moon-Ju;Park, Joon-Suk;Kang, Kyung-Sun;Hwang, Seung-Yong
    • Molecular & Cellular Toxicology
    • /
    • v.2 no.2
    • /
    • pp.120-125
    • /
    • 2006
  • Phenytoin is an anti-epileptic. It works by slowing down impulses in the brain that cause seizures. The recent microarray technology enables us to understand possible mechanisms of genes related to compounds which have toxicity in biological system. We have studied that the effect of a compound related to hepatotoxin in vitro system using a rat whole genome microarray. In this study, we have used a rat liver epithelial cell line WB-F344 and phenytoin as a hepatotoxin. WB-F344 was treated with phenytoin for 1 to 24 hours. Total RNA was isolated at times 1, 6 and 24h following treatment of phenytoin, and hybridized to the microarray containing about 22,000 rat genes. After analysis with clustering methods, we have identified a total of 1,455 differentially expressed genes during the time course. Interestingly, about 1,049 genes exhibited differential expression pattern in response to phenytoin in early time. Therefore, the identification of genes associated with phenytoin in early response may give important insights into various toxicogenomic studies in vitro system.

Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings (13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석)

  • Chang, Jeong-Ho;Lee, Dong-Keun;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

An e- Business Maturity Model for Small and Medium-sized Enterprises and case studies (중소기업 e-비즈니스 성숙도 모형과 적용사례)

  • 김은홍;서정우;안성만;장성봉;이석준
    • Journal of Information Technology Applications and Management
    • /
    • v.10 no.3
    • /
    • pp.109-120
    • /
    • 2003
  • This paper proposes an e-business maturity model for small and medium-sized enterprises. The model consists of five maturity levels, which are on-line access, on-line business, matured on-line business, and full on-line business from least matured level to most matured level. The model can be used to assess e-business maturity level of individual enterprises. individual enterprise's maturity level can be assessed by examining sample check lists. Additionally, this paper summarizes the results of an application of the proposed model to a couple of small and medium-sized enterprises. This model can also be used to suggest what individual enterprises need to be upgraded towards higher maturity level.

  • PDF

Development of On-line Control System Using RFID On the Prison (RFID를 이용한 교도소의 온라인 통제 시스템 개발)

  • Park, Seung-Hwan;Ku, Ja-Yl
    • 전자공학회논문지 IE
    • /
    • v.45 no.4
    • /
    • pp.74-79
    • /
    • 2008
  • The paper represented central management system of dual direction that does opening and shutting, real-time check of various doors of the prison in the on-line network. To remove a fault of 125kHz RFID technology, we use 13.56MHz RFID technology, can solve the problem of the maintenance and trust, development of on-line control and management system that ring the alarm in the abnormal opening and shutting doors.

Application of Fault Current Limiter in 22.9kV KEPCO power distribution line (22.9kV 지중선로용 한류기 한전 실계통 시범적용)

  • Kim, Min Jee;Park, Kyungwon;Ahn, Kil-Young;Kim, Young-keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1034-1035
    • /
    • 2015
  • Watertight 25.8 kV/600 A/12.5 kA fault current limiters (FCLs) have successfully installed in five areas (Incheon, Seoul, Gyeong-gi, Daejeon, Suwon) on KEPCO power distribution line for the purpose of commercial demonstrations. The fault current limiting operation of this FCL, which includes functions of sensing, commutation, and reduction of fault currents, is perfectly completed within 1 cycle immediately after fault occurs. The performance of FCL was verified by short circuit test, impedance test, insulation test, temperature-rise test, and control test, etc at PT&T in LS industrial systems, which is the official certification institute in Korea. In 2013, and also the FCL field test was performed in order to test the protection coordination between conventional relays and FCL, on the 1.5 kA and 5.0 kA faults, which were made by connecting the Artificial Fault Generator (AFG) to the distribution line in test grid at KEPCO Power Testing Center. The next step of this project is to check the FCL conditions caused by real external environment, and acquire the various data from five regions installed with FCL. In this paper, we intend to explain the FCL specifications and performance characteristics, and check the expected effect by application of FCL to power distribution line based on the power system analysis of an application site.

  • PDF