• Title/Summary/Keyword: Limiting efficiency

Search Result 259, Processing Time 0.022 seconds

The Limiting Current Density and the Regeneration of a Heterogeneous Ion Exchange Membrane in a Nickel Plating Rinse Waters Treatment Process by Electrodialysis (전기투석에 의한 니켈도금 폐수처리 공정에서 한계전류밀도와 불균질 이온교환막의 재생)

  • 윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.2
    • /
    • pp.38-46
    • /
    • 2001
  • In this work, the heterogeneous ion exchange membrane was used in a electrodialysis apparatus to treat a Ni planting rinse water because the heterogeneous ion exchange membrane was excellent efficiency as compared with low manufacturing cost, was easy to make, and had a good mechanical properties. For a regeneration of membrane and to obtain the optimal condition for a scale-up of apparatus after treating Ni plating rinse water, we would find about the limiting current density and the concentration polarization. When the Ni plating rinse water 150mg/L was treated with the electrodialysis apparatus using the heterogeneous ion exchange membrane, the limiting current density was about $1.49{\;}mA/\textrm{cm}^2$. And the limiting current density increased with the flow rate and concentration of Ni plating rinse water. We recognized that the used membrane could be reused by periodic backwashing because efficiency was constant when the membrane was backwashed after treating wastewater.

  • PDF

On the Steady State Availability of Age-Dependent Minimal Repair Model

  • Cha, Ji-Hwan;Kim, Jae-Joo
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.17-22
    • /
    • 2002
  • Availability is an important characteristic of a repairable component. Iyer(1992) obtained the 'limiting efficiency'(not the `steady state availability') of the age-dependent minimal repair model which was first considered by Block et al.(1985). However the existence of the steady state availability of the model has not been reported. In this note, the existence of the steady state availability of the model is shown and a brief remark on the importance of the property is given.

  • PDF

Optical Limiting Properties of Multi-Walled Carbon Nanotube Suspensions (다중벽 탄소 나노튜브 현탁액의 광 리미팅 특성)

  • Yu Hyojung;Kim Sok Won
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.449-454
    • /
    • 2004
  • The optical limiter is an optical component which reduces laser beam intensity for the protection of eyes and light sensors. Carbon nanotube is now known as a highly efficient optical limiting material. Optical limiting effect of the multi-walled carbon nanotube suspensions, in several kinds of solvents such as distilled water, chloroform, ethanol and ethylene glycol, were measured in the range from room temperature to near to the boiling points of the solvents. The pulsed Nd:YAG laser whose wavelength is 1064 nm and pulse duration is 6 ns was used as a light source. The experimental result shows that the limiting efficiency was reduced as the temperature increased, and the suspension which has lower boiling point, viscosity and surface tension has highest efficiency.

On Multipurpose Replacement Policies for the General Failure Model

  • Cha, Ji-Hwan
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.2
    • /
    • pp.393-403
    • /
    • 2003
  • In this paper, various replacement policies for the general failure model are considered. There are two types of failure in the general failure model. One is Type I failure (minor failure) which can be removed by a minimal repair and the other is Type II failure (catastrophic failure) which can be removed only by a complete repair. In this model, when the unit fails at its age t, Type I failure occurs with probability 1-p(t) and Type II failure occurs with probability p(t), $0{\leq}p(t){\leq}1$. Under the model, optimal replacement policies for the long-run average cost rate and the limiting efficiency are considered. Also taking the cost and the efficiency into consideration at the same time, the properties of the optimal policies under the Cost-Priority-Criterion and the Efficiency-Priority-Criterion are obtained.

  • PDF

A Study on the Limiting Factors in Wastewater Treatment by Contact Oxidation Process (접촉담화공정에 의한 폐수처이에 있어서의 제한요권에 관한 연구)

  • 황상용;손종열;우완기
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.2
    • /
    • pp.45-52
    • /
    • 1990
  • This study is to discuss limiting factors influenced on the removal efficiency of organic materials investigated using the polypropyrene biofilter which appropriate to attach micro-organism in order to apply the contact oxidation proce,:5. The results obtained in the experiment were as follows : 1. In the range o: pH 4.0~ 12.0 was obtained the removal efficiency of COD higher than 85% It was proved that variation of pH(4.0 ~ 12.0) was nothing to do with the removal efficiency of substrate in continuous reactor. 2. Temperature to obtain removal efficiency of COD higher than 85% was $10^{\circ}$ ~$40^{\circ}$. Removal efficiency of COD was no less than those at high temperature if MLVSS concentration was maintained 8,000~ 15,000 m/1. 3. In the continuous reactor, the volumetric loading of COD for removal efficiency higher than 95% had to be 0.5~1.5 kg COD/.d below. And then the HRT was Bhrs. 4. In comparison with the conventional activate sludge process, the contact oxidation process was excellent in removal efficiency, sludge production rate and maintenance.

  • PDF

Development of Multi-dimensional Limiting Process for Multi-dimensional Compressible Flow (다차원 압축성 유동 해석을 위한 MLP 기법의 개발)

  • 윤성환;김종암;김규홍
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.7
    • /
    • pp.1-11
    • /
    • 2006
  • Through the analysis of conventional TVD limiters, a new multi-dimensional limiting function is derived for an oscillation control in multi-dimensional flows. Then, Multi-dimensional Limiting Process (MLP) is developed with the multi-dimensional limiting function. The major advantage of MLP is to prevent oscillations across a multi-dimensional discontinuity, and it is readily compatible with more than 3rd order spatial interpolation. Moreover, MLP shows a good convergence characteristic in a steady problem and it is very simple to be implemented. Through numerical test cases, it is verified that MLP substantially improves accuracy, efficiency and robustness both in continuous and discontinuous flows.

Effects of Process Variables on The Electrochemical Recovery of Palladium in A HCl Solution

  • Kim, Min-Seuk;Lee, Jae-Chun;Kim, Won-Baek
    • Resources Recycling
    • /
    • v.14 no.1
    • /
    • pp.55-63
    • /
    • 2005
  • This study investigated the electrochemical recovery of palladium in a HCl solution that is used for palladium leaching. The high acidity of HCl solution and the low concentration of Pd ions increased the cathodic overpotential and reduced the limiting current density. Lowering the current density produced dense deposits; however, they were under high tensile stress. Raising the temperature affected both the densification and the stress, which enabled the attainment of dense Pd deposits under low stress. Lowering the current density and raising the temperature up to 70$^{\circ}C$ was recommended for the recovery of palladium as sound bulk Pd deposits. Current efficiency was over 85% at the initial stage of recovery may decrease the current efficiency, since a low Pd ion concentration results in a low limiting current density.

NUMERICAL SOLUTION FOR ROBOT ARM PROBLEM USING LIMITING FORMULAS OF RK(7,8)

  • Senthilkumar, S.
    • Journal of applied mathematics & informatics
    • /
    • v.26 no.3_4
    • /
    • pp.793-809
    • /
    • 2008
  • The aim of this article is focused on providing numerical solutions for system of second order robot arm problem using the RK-eight stage seventh order limiting formulas. The parameters governing the arm model of a robot control problem have also been discussed through RK-eight stage seventh order limiting algorithm. The precised solution of the system of equations representing the arm model of a robot has been compared with the corresponding approximate solutions at different time intervals. Results and comparison show the efficiency of the numerical integration algorithm based on the absolute error between the exact and approximate solutions. Based on the numerical results a thorough comparison is carried out between the numerical algorithms.

  • PDF

Operation of Electrodialysis at Over Limiting Current Density (한계전류밀도 이상에서 전기투석공정의 운전)

  • 박진수;최재환;문승현
    • Membrane Journal
    • /
    • v.12 no.3
    • /
    • pp.171-181
    • /
    • 2002
  • The parameter which determines the plateau length of current-voltage curve for ion- exchange membranes was studied at various concentrations of NaCl and different flow rates. Moreover, the feasibility of the electrodialytic removal of 0.1 M NaCl solution at various current densities was tested by assessing the electrodialysis performance parameters such as salt removal efficiency, current efficiency, energy consumption and water dissociation. The diffusion boundary layer (DBL) thickness decreased with the NaCl concentration and flow rate of fled solution and it was observed that the plateau length of current-voltage curves was related with the DBL thickness. The removal efficiency and current efficiency were not affected significantly by the current densities even at the overlimiting current region indicating that most current were passed by electrolyte, and water dissociations are not responsible for the overlimiting current. Energy consumption increased when the current density supplied exceeded the limiting current density (LCD) values, because additional energy was necessary to overcome the plateau potential. Beyond the LCD values the energy consumption required to get a certain removal efficiency was not affected by the current density applied. The result suggests that it is allowed to operate electrodialysis processes at as high as possible current density unless water-splitting does not occur.

A Study on the impact on the quality of hemming the number of hemming process (중소형 회로 차단기에 적용 가능한 한류 메커니즘의 개발)

  • Lee, Je-Duk;Park, Jong-Sik;Im, Jae-Guk;Park, Dong-Hee;Park, Min-Ho;Choi, Kye-Kwang;Kim, Sei-Hwan;Yun, Jae-Woong;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.10 no.1
    • /
    • pp.41-45
    • /
    • 2016
  • Electrical equipment in factories, buildings, etc. with the development of the industry has become a large capacity. By the development, electric load also become diversified and there is also highly functional requirements being electrical equipment. Particularly in the small and medium-sized circuit breakers, tend to preferentially consider the economy stands out and improvements in safety, ease of mounting and connection through the modularity of the basic dimensions compact and cost to block expansion of the scope of the development of capacity, etc. The product having a competitive has been strongly required. In order to implement the circuit breakers of breaking capacity and compact at the same time taking into account the economic development of this technology applied to the current-limiting mechanism is essential budget or the current limiting mechanism is currently available mechanisms applicable to small and medium-sized frame (frame) can not do it. In this paper, at the same time satisfying the economic efficiency, by minimizing the load force of the moving contactor (moving contactor) to be applied to small and medium frame other hand to secure the economical efficiency without using high speed contact parting acceleration of the moving contactor conventional current-limiting mechanism, and to develop a current-limiting mechanism that can be satisfied with the same or higher performance to meet the needs of the market.