Browse > Article

A Study on the impact on the quality of hemming the number of hemming process  

Lee, Je-Duk (Department of Metalmold Engineering, Kongju national university)
Park, Jong-Sik (Department of Metalmold Engineering, Kongju national university)
Im, Jae-Guk (Department of Metalmold Engineering, Kongju national university)
Park, Dong-Hee (Department of Metalmold Engineering, Kongju national university)
Park, Min-Ho (Department of Metalmold Engineering, Kongju national university)
Choi, Kye-Kwang (Department of Metalmold Engineering, Kongju national university)
Kim, Sei-Hwan (Department of Metalmold Engineering, Kongju national university)
Yun, Jae-Woong (Department of Metalmold Engineering, Kongju national university)
Lee, Chun-Kyu (Department of Metalmold Design Engineering, yuhan College)
Publication Information
Design & Manufacturing / v.10, no.1, 2016 , pp. 41-45 More about this Journal
Abstract
Electrical equipment in factories, buildings, etc. with the development of the industry has become a large capacity. By the development, electric load also become diversified and there is also highly functional requirements being electrical equipment. Particularly in the small and medium-sized circuit breakers, tend to preferentially consider the economy stands out and improvements in safety, ease of mounting and connection through the modularity of the basic dimensions compact and cost to block expansion of the scope of the development of capacity, etc. The product having a competitive has been strongly required. In order to implement the circuit breakers of breaking capacity and compact at the same time taking into account the economic development of this technology applied to the current-limiting mechanism is essential budget or the current limiting mechanism is currently available mechanisms applicable to small and medium-sized frame (frame) can not do it. In this paper, at the same time satisfying the economic efficiency, by minimizing the load force of the moving contactor (moving contactor) to be applied to small and medium frame other hand to secure the economical efficiency without using high speed contact parting acceleration of the moving contactor conventional current-limiting mechanism, and to develop a current-limiting mechanism that can be satisfied with the same or higher performance to meet the needs of the market.
Keywords
Current limiting breaking; Ccircuit breaker; Cost down;
Citations & Related Records
연도 인용수 순위
  • Reference
1 주남규, "DC차단기 개발에 관한 연구", 강원대 대학원 박사학위 논문, 2014.
2 오준식, 나칠봉, 이성만, 임종득, 함길호, "저압 차단기의 한류차단 현상에 대한 연구, 대한전기학회 하계학술대회 논문집, pp. 940-942, 2000.
3 山崎 誠, 潮崎 克?, 中村 司, "ツインブレ?カを?現した技術開?, 富士時報, Vol.63 No.2 1990.