직류전동차 탑재용 피뢰기의 최적선정에 관한 연구 (A Study on the Best Selection of Lightning Arrester for DC Electric Traction Vehicles)

  • 차명수;송재용;김일권;길경석;이대성;박재규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1519-1520
    • /
    • 2006
  • This paper describes a selection and application recommendations of ZnO arresters on DC electric traction vehicles. We measured and analyzed the system voltages applied to arresters and the surge currents flowing arresters on DC electric traction vehicles under operation to decide the Continuous Operating Voltage($U_C$), the Rated Voltage($U_R$), and the Nominal Discharge Current($I_n$). System voltages measured up to 1,800 V during anti-breaking in 1,500 V-system, and surge currents were recorded up to 3 times per running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From these results and the standard EN50163, we proposed the Continuous Operating Voltage($U_C$) the Rated Voltage($U_R$) for the $1,500V_{dc}$ electric traction vehicles.

  • PDF

지중방전현상에 의한 접지시스템의 써지 임피던스의 저감 (The Decreasing of Surge Impedance of Grounding System by using Discharge)

  • 정재기;강지원;양병모;김홍필
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.55-61
    • /
    • 1998
  • 일반적으로 접지시스템에서 접지저항계산은 저주파수의 전원이 대지에 인가될 때 발새외는 대지전위상승을 측정하여 계산한다. 그러나 뇌격과 써지 엄펄스와 같은 고주파수에 해당하는 전원에 대해서는 현재의 접지 시스템에서 고려하고 있지 않기 때문에 전기설비에 매우 큰 영향을 미칠 우려가 있다. 그래서 이 논문에 서는 뇌격이 전극봉에 인가되었을 때 발생되는 접지 임피던스의 과도현상을 실험하였다. 그리고 이 실험 결과는 이론적 해석과 잘 일치하였으며 지중방전현상이 임펄스 임피던스 저감에 영향올 미친다는 사실을 확인 할 수 있었다.

  • PDF

가공배전선로의 전력설비 감시를 위한 유비쿼터스 센서 (Ubiquitous Sensors for Supervision of Power Facilities in Overhead Power Distribution Lines)

  • 길경석;박대원;김일권;최수연;박찬용
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.59-65
    • /
    • 2007
  • 최근 유비쿼터스 센서네트워크 기술이 전력설비관리에 적용되어 오고 있다. 본 연구에서는 가공배전선로에서 전력용변압기와 피뢰기를 관리할 수 있는 유비쿼터스 센서의 설계 및 제작에 대해 기술하였다. 이 센서들은 8-[bit] 마이크로프로세서, IEEE 802.15.4기반 무선통신모듈과 주변 전자회로로 구성되어 있다. 변압기의 부하 및 서지전류 측정에는 1000[A]까지 포화되지 않고 선형성을 유지할 수 있도록 공심형 로고우스키 코일을 제작하여 적용하였다. 피뢰기를 흐르는 $50[{\mu}A]{\sim}1[mA]$의 미소누설전류를 측정하기 위하여 180[Hz]에서 $10^5$의 고투자율을 갖는 영상변류기를 사용하였으며, 피뢰기 감시모듈의 -3[dB] 주파수 대역은 12[Hz]에서 1.24[kHz]이다.

안정성 개선을 위해 열폭주 방지 기능을 내장한 배리스터 설계에 관한 연구 (A Study on the Design of Varistor Prevented from Thermal Runaway to Improve Safety)

  • 정태훈;신희상;조성민;이희태;이준규;김재철
    • 조명전기설비학회논문지
    • /
    • 제24권2호
    • /
    • pp.69-76
    • /
    • 2010
  • 본 논문은 SPD에 사용되는 배리스터에 대한 성능을 개선하기 위해 저압 배전계통에 사용하는 ZnO 배리스터의 소자 표면에 온도감응 소재를 도포한 것을 내장한 SPD의 신뢰성과 안정성을 개선하였다. '열폭주 방지 기능을 내장한 배리스터'설계를 통해 SPD내에 장착 시 열 보호기능의 단로기의 기능에 대한 trade-off 관계해석(trade-off:단로기에 단일펄스피크전류(ITM), 다중펄스피크전류(ITSM)에 대한 신뢰성과 배리스터 소자의 열화 및 수명한계에 따른 열폭주 현상을 예방하기 위한 단로기의 안정성 확보를 위한 최적의 설계)을 통해 신뢰성과 안정성을 확보하였고 열 보호기능을 배리스터 내부에 적용하여 SPD제작시 소형/경량화가 가능하도륵 하였다.

초크코일을 이용한 SPD 조합회로의 잔류전압 저감기법 (A Method for Reducing the Residual Voltage of Hybrid SPD Circuit Using Choke Coil)

  • 조성철;엄주홍;이태형
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.96-101
    • /
    • 2007
  • 가스방전관(GDT)은 내부 정전용량이 작아서 통신용 서지보호기로 널리 사용되고 있는 소자이다. 하지만 가스방 전관의 동작개시를 위해서는 방전이 개시될 수 있는 충분한 전압과 시간이 필요하며, 이 동작개시전압은 피보호 회로가 서지에 민감한 장비일 경우 손상을 줄 수 있을 만큼 크므로 최근에는 조합 형태로 적용하는 경우가 대부분이다. 이렇게 초기 과전압이 상당 부분 존재하는 가스방전관에는 추가적으로 TVS나 필터 등을 통해 피크 전압을 제한해 주어야 한다. 본 논문에서는 공통모드 초크코일을 이용한 필터를 적용하여 공통모드와 차동모드의 조합회로를 구성하고, 주파수 대역이 다른 뇌임펄스 전압과 ring wave 전압을 인가하여 파형에 따른 조합회로의 특성을 확인하였다. 다단으로 보호되는 과정을 각각의 측정점에서 잔류전압을 측정하여 단계별로 적용한 SPD들이 어떻게 동작하는지를 실측데이터로 제시하였다. 각 단계의 잔류전압을 비교했을 때 공통모드에 비하여 차동모드에서 서지전압을 제한하는 성능이 보다 효과적이다.

서지 보호기의 열화 특성과 온라인 진단장치 (Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices)

  • 박경수;왕국명;황성철;김선재;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

RCD와 SPD의 접속 위치에 따른 보호협조 (Protection Coordination Associated with Connection Location of Residual Current Devices and Surge Protective Devices)

  • 이복희;박희열;신건진;배관영;류춘형;이강희
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.100-106
    • /
    • 2013
  • In this paper, in order to analyze lightning impulse response characteristics in combined installations of SPDs and RCDs, surge protection coordination between SPDs and RCDs are experimentally investigated by using the combination wave generator. Six different types of single-phase residual current operated circuit-breakers with integral overcurrent protection for household and similar uses(RCBOs) being present on the domestic market are tested according to KS C IEC 61009-1 standard. As a result, when a class I SPD is located on the source side of an RCBO, all kinds of specimens are able to provide the proper coordination between the SPD and RCBOs without nuisance tripping, unintended operation or damage due to test impulse currents. However, in the case that the class II SPD is located on the load side of RCBOs, a lot of L-N mode injected currents is split into the RCBO, and a few RCBOs are damaged. Coordination between SPDs and RCDs is not valid and a role of SPDs is of no use. When combining SPDs with RCDs, it is necessary to select SPDs and RCDs in consideration of the protection voltage level of metal oxide varistor embedded in RCDs.

산화아연 피뢰기 소자와 전극사이에 발생하는 방전광 현상 (Discharge Luminous Phenomena Caused Between ZnO Surge Arrester Block and Electrodes)

  • 이복희;박건영;강성만
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.44-50
    • /
    • 2005
  • 본 논문에서는 산화아연(이하 ZnO) 피뢰기 열화진행의 한 요인으로 예측되는 전극과 ZnO소자 사이에서 발생하는 방전광 현상에 관한 연구를 수행하였다. 이를 위해 $8/20[{\mu}s]$, 최대 10[kA]의 뇌임펄스전류를 발생시키는 뇌임펄스전류 발생장치를 설계${\cdot} $제작하였다. 실험결과, 상${\cdot}$하부의 전극 부근에서 발생하는 방전광의 형상은 인가되는 뇌임펄스의 극성에 따라 다르게 나타났으며 상대적으로 (-)극의 전극부근에서 방전광이 더 강하고 활발하게 발생하는 것으로 관찰되었다. 또한 전극의 면적에 따른 방전광의 세기는 전극의 면적이 증가할수록 감소하는 것으로 관측되었다. 동시에 전극과 소자의 접촉상태도 방전광의 발생과 매우 밀접한 관계가 있는 것으로 확인되었다. 따라서 배전급 ZnO피뢰기의 기존 전극구조는 보완이 필요하며 ZnO피뢰기 제품의 성능향상 및 지속적인 성능유지를 위해서는 환형구조 대신 내부면적이 있는 원판구조로 교체하는 것이 바람직하다고 판단된다.

변전소 접지계통 모델링 변화에 따른 과도상태 영향 분석 (Analysis of Power System Transients Recording to Substation Grounding System Models)

  • 정채균;최종기;이원교;이동일;황갑철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.388-390
    • /
    • 2008
  • This paper discusses the effect according to the change of grounding system modeling in substation. Substation grounding system is modelled by CDEGS and EMTP. Node voltages of grounding system is variously analysed by 3 grounding cases and 4 kinds of transient frequency ranges. The results of this paper will contribute to advance the grounding system modeling of substation in the range of high frequency transient such as lightning surge.

  • PDF

지중배전선로용 피뢰기를 고려한 과도현상 해석 (Analysis of Transient Phenomena Considering Arrester in Underground Distribution Line)

  • 윤창섭;이종범;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.276-278
    • /
    • 2007
  • This paper describes the analysis to install an arrester for an underground distribution line effectively. Currently, the underground distribution cable is protected by the arrester connected with overhead distribution line. However, riser pole arrester can't protect all parts of cable like the end of the underground distribution cable. To solve this problem, we installed the arrester on each cable and have measured the overvoltage made by lightning surge in each situation. The location to get effective results has been decided from the measured voltage above.

  • PDF