• 제목/요약/키워드: Lighting Engineering

검색결과 1,246건 처리시간 0.022초

Daylighting Performance of Topside Lighting Systems for Different Orientations (방위에 따른 정측창 시스템의 채광성능 평가)

  • Kong, Hyo-Joo;Lee, Jin-Seoung;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • 제29권1호
    • /
    • pp.11-17
    • /
    • 2009
  • Daylighting is core of sustainable design in most buildings. Well-designed daylighting systems can significantly reduce or even eliminate the electric lighting loads during the day time, including air conditioning energy loads. Among window systems. the topside lights systems including monitor lighting, sawtooth lighting, sunscoop and, lightscoop is one of the most popular apparatus to improve the lighting quantity. Also they are important both in terms of energy savings and visual quality. The objective of this study is to analyse daylighting performance of topside lighting system for different orientations. Four types of topside lighting system were tested and comparpd: monitor lighting, sawtooth lighting, lightscoop and sunscoop. Totally 25 measuring points of illuminance on the horizontal plane were monitored from 09:00 to 17:00 on October 6, 2008. Agilent data logger and photometric sensors Li-cor were used. Comparisons with a light factor is discussed. The results found in this study would mean that there were no significant differences in light factor between three cases.

ACHIEVING CONSISTENCY IN LIGHTING SCHEMES FOR CONSTRUCTION WORK ZONES THROUGH LIGHTING SIMULATION

  • Khaled Nassar;Soo-Young Kim
    • International conference on construction engineering and project management
    • /
    • The 2th International Conference on Construction Engineering and Project Management
    • /
    • pp.269-278
    • /
    • 2007
  • Nighttime construction is being adopted by many state DOT's as a way to mitigate the impact of construction operations on the traveling public. Although a number of states have developed standard specifications for nighttime lighting, these standards are usually in the form of generic requirement statements that only specify minimum illuminance levels. The lighting standards do not include specific ways to achieve this illuminance level such as lighting arrangements and configurations for various work zone plans and construction operations. This leaves confusion between the traffic engineers and the contractors and does not guarantee consistency in those plans, thus affecting productivity and safety (lighting conditions account for 18% to 28% of work zone accidents). The main objective of this study is to utilize three dimensional animation and lighting analysis software to study and model lighting conditions of a construction site. This is expected to increase the safety and productivity of construction operations by achieving consistency in work zone lighting schemes. A computerized model was developed, called Nitelite. Various lighting schemes can be studied using the software to provide for typical applications including lighting fixture's locations, luminance, mounting height, tilt angle, and fixture type. The results from the developed software tool were validated through comparisons with previous research conducted using field measurements.

  • PDF

A Smart Lighting Management System with Satisfaction of User's Lighting Requirements (사용자 요구조도 만족 스마트 조명 관리시스템)

  • Shin, Dae-Sik;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제27권6호
    • /
    • pp.1-8
    • /
    • 2013
  • In this paper, we proposed a smart lighting management system controls the lighting efficiently to reduce energy consumption while satisfying user's lighting requirements. The proposed system considers the available daylight intensity and indoor light source to satisfy the lighting requirements of each user according to the work environment. In addition, for user convenience, we have developed different user interfaces for lighting control including local interface, and remote interface through internet or Bluetooth for personal computer as well as smart phones. The proposed system satisfies the lighting requirements of each user according to the corresponding work environment. The proposed smart lighting management system utilizes the lighting energy efficiently, and can be considered a significant contribution towards future green buildings.

Alternating Current Input LED Lighting Control System using Fuzzy Theory

  • Lee, Jae-Kyung;Yim, Jae-Hong
    • Journal of information and communication convergence engineering
    • /
    • 제19권4호
    • /
    • pp.214-220
    • /
    • 2021
  • In this study, we constructed several scenarios that are required for LED lighting, and we designed and implemented an LED lighting control system to operate these scenarios to confirm their behavior. An LED lighting control system is a hybrid control board that is designed by combining LED controllers and SMPS, consisting of an AC/DC power supply part that converts AC 220 V into DC 12 V, and a drive and control part that controls the scenario and color of the LED module. Conventional LED light controllers have an input power of DC 12 V, so when using the input AC 220 V, the SMPS must be connected to the LED light controller. To eliminate this inconvenience, a hybrid LED lighting control system was configured to combine LED lighting controllers and SMPS into one control system. Furthermore, we designed a control system to represent the most appropriate color according to the input of the distance and illumination using a fuzzy control system to conduct computer simulations.

A preliminary Study and suggested Evaluation Methodology for the Improved Fashion Shop Lighting Design using Museum Lighting Design (박물관 전시조명 방식을 적용한 패션 매장의 조명환경 개선에 관한 사전 연구 및 평가방법론 제안)

  • Ko, Tae-Kyoung;Kim, In-Tae;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제29권4호
    • /
    • pp.37-46
    • /
    • 2015
  • Lighting in a fashion shop has an effect on customers, highlights the products on the shelf, and has become more important. Even though lighting has a significant effect on customers, the studies on fashion shop lighting have primarily focused on how to create lighting which can influence customers' purchase behavior, and their awareness and expectation. On the contrary, it's been hard to find a study on a quantified fashion shop lighting plan considering customer confidence. In a current fashion shop lighting plan, display lighting is planned indiscreetly. Therefore, this study conducted an investigation of the light environment of the current fashion shop and museum exhibits lighting. Through such processes, the possibility of applying fashion store display lighting environments was investigated. Finally, for the assessment of museum exhibitions lighting applying fashion store display lighting environments, a subjective evaluation method using light simulation was proposed.

Study of Efficiency Test and Subjective Responses about Pendent Task Lighting System Using Phosphor Luminescent Film LED (광기여 필름 LED 팬던트 작업조명시스템 주관평가와 성능검증)

  • Cha, Kwang-Seok;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제23권3호
    • /
    • pp.188-193
    • /
    • 2011
  • For a long time work or study, pendent task lighting system prepared with phosphor luminescent film LED was developed for eye protection and working efficiency improvement. Developed lighting system was used together with pendent and ambient lighting. Such as, we made comfortable lighting environment system. Evaluation for developed lighting system, that had proceeded to Mock-up test and subjective evaluation. Also It had proceeded that lighting environment analyzed and compatibility valuation of installation. In subjective evaluation, the students have expressed themselves satisfied to phosphor luminescent film LED lighting system. In Mock-up test, It is not problem to intensity of illumination, luminance and color temperature. Therefore, developed LED lighting system was installed at the Daegu apartment. It is having a P.O.E study progress to phosphor luminescent film LED lighting system.

Optical System Design of Freeform Lens Lighting as a Replacement for Gobo Lighting (고보 조명을 대체할 수 있는 Freeform Lens 조명 광학계 설계)

  • Byeong-Mun Yang;Min-Gyu Kim;Mee-Suk Jung
    • Korean Journal of Optics and Photonics
    • /
    • 제34권6호
    • /
    • pp.276-282
    • /
    • 2023
  • In this paper, we designed a lighting optical system using a freeform lens as a substitute for expensive gobo lighting. Unlike gobo lighting, freeform lens lighting does not use an image mask, and it can form and project an image directly on the lens surface using only a single lens, thus reducing the cost compared to gobo lighting. In order to verify the performance of freeform lens lighting with these advantages, we conducted an illuminance simulation. As a result, it was confirmed that it can replace gobo lighting because it has an illuminance distribution similar to the image we want to irradiate and a light efficiency of 47% similar to the performance of gobo lighting.

A Reconfigurable Lighting Engine for Mobile GPU Shaders

  • Ahn, Jonghun;Choi, Seongrim;Nam, Byeong-Gyu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권1호
    • /
    • pp.145-149
    • /
    • 2015
  • A reconfigurable lighting engine for widely used lighting models is proposed for low-power GPU shaders. Conventionally, lighting operations that involve many complex arithmetic operations were calculated by the shader programs on the GPU, which led to a significant energy overhead. In this letter, we propose a lighting engine to improve the energy-efficiency by supporting the widely used advanced lighting models in hardware. It supports the Blinn-Phong, Oren-Nayar, and Cook-Torrance models, by exploiting the logarithmic arithmetic and optimizing the trigonometric function evaluations for the energy-efficiency. Experimental results demonstrate 12.7%, 42.5%, and 35.5% reductions in terms of power-delay product from the shader program implementations for each lighting model. Moreover, our work shows 10.1% higher energy-efficiency for the Blinn-Phong model compared to the prior art.

A Study on Manufacturing Processes of Street-lighting System using COH LED Package (COH형 LED 패키지를 이용한 가로등 생산공정에 관한 연구)

  • Lee, Jong Hang;Yang, Keun Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제30권3호
    • /
    • pp.349-355
    • /
    • 2013
  • Recent high oil price results in the development of energy saving technology such as LED lighting system. Street-lighting system using COH LED package can save energy because the heat dissipation through cupper base is better than conventional technology. Studies on manufacturing processes of lighting system are insufficient even though LED package design and its heat analysis have been studied. This study focuses on the problem and solution of manufacturing processes such as LED packaging process, optimized emission angle, and LED bar dimension for mechanical assembly. As a result, we established better manufacturing alternatives of LED packaging and street-lighting system with higher lighting efficiency of 84 lm/W, as well as good illumination intensity of 39.7 lux at 6 m from lighting source.

Improving CRI and Scotopic-to-Photopic Ratio Simultaneously by Spectral Combinations of CCT-tunable LED Lighting Composed of Multi-chip LEDs

  • Kim, Jong-Oh;Jo, Hyeong-Seob;Ryu, Uh-Chan
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.247-252
    • /
    • 2020
  • Important determinants for selecting outdoor lighting are the color-rendering index (CRI) and scotopic-to-photopic (S/P) ratio of the lighting units. The higher the S/P ratio, the better energy savings and visual performance. In this study, CCT-tunable LED lighting units were optimized and fabricated by spectral combination of red, green, blue, and yellow LEDs. The measured results for RGB LEDs provided S/P ratios of 1.55~2.58 and those of RGBY LEDs gave 1.46~2.46 to the correlated color temperatures (CCTs) ranging from 2700 K to 6500 K, with CRI values of over 80 at the same time.