• Title/Summary/Keyword: Light-emitting Diode

Search Result 1,407, Processing Time 0.028 seconds

The Effects of Illuminance and Correlated Color Temperature on Visual Comfort of Occupants' Behavior

  • Yoon, Gyu Hyon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • The preferred illumination environment in accordance with the actions taken by the occupants of the rooms in residences differs significantly between different cultures and circumstances in and out of the country. In this regard, the purpose of this study is to evaluate the visual performance of various illumination environments in residential spaces by allowing the participants of the experiments to select the kind of illumination environment they prefer as the occupants of the room. For this purpose, we prepared a mock-up residential space of $6.2m{\times}4.5m{\times}2.5m$, where the experiments for this study were conducted. Then, three illuminance settings (30lx, 100lx, and 150lx) and three color temperature settings (2700k, 4000k, and 6500k) were selected as the properties of the physical environment where the tests were to be conducted. The survey was conducted with 30 study subjects, with whom the level of visual comfort and the lighting adjustment evaluation by different activities were carried out. The level of visual comfort in lighting in a residential context turned to be more influenced by the color temperature and illuminance compared to other factors. Except for the test item, 'comfort,' all test items showed positive reactions when the illuminance was 150lx, which was rather light. In 'comfort,' the test subjects appeared to prefer warm color temperature of 2700k. As we allowed the occupants to adjust the lighting environment in accordance with the conditions of the subjects and the activities they performed, the subjects regarded 150lx - 4000k setting as comfortable, while they preferred 150lx-5400k configuration for working. In case of resting, the subject answered that the configuration of 30lx -2700k setting to be visually comfortable.

A Study on the Heat Radiation of LED Luminaires and the Indoor Temperature Increase (LED 등기구의 발열과 실내온도 상승에 관한 연구)

  • Kim, Dong-Geon;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.9
    • /
    • pp.738-742
    • /
    • 2012
  • This paper conducted a study on how the heat radiation of light emitting diode(LED) luminaires affects the indoor temperature increase. The effect was compared with that of a 20 W compact fluorescent lamp(CFL) and a 50 W MR16 halogen lamp which are most widely used inside of cruises, a LED downlight and a 4W MR16 LED replacing each of them. We installed a luminarie inside a thermally shielded chamber, measuring the temperature changes under the same volume every 5 minutes and compared the result with theoretically calculated heat radiation. The temperature changes in the chamber was measured four times, on seven hours' period in order to keep sufficient time once the temperature reaches the thermal equilibrium state. The results showed that the temperature of the 20 W E26 CFL and the 10 W LED downlight increased by $21.1^{\circ}C$ and $10.4^{\circ}C$ respectively, while that of the 50 W halogen MR16 and the 4 W LED MR16 increased by $33.9^{\circ}C$ and $4.8^{\circ}C$ respectively. The experimental heat radiation were calculated from the results and the experimental heat radiation of the CFL and the LED downlight were 171.5 cal and 86.5 cal, and those of the halogen MR16 and the LED MR16 were 275.3 cal and 36.5 cal. Therefore, the heat radiation was reduced by 49.5% and 86.7%, respectively, by replacing conventional light source with LED. In conclusion, we can expect a reduction of power consumption in air condition system and the effect on indoor temperature increase by application of LED luminaires.

Design of a LED driver using digital control methode (디지털 방식을 이용한 LED 구동 드라이브 설계)

  • Lee, Sang-Hun;Song, Sung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.2003-2008
    • /
    • 2012
  • A drive system is necessary to operate LED by an LED illumination system. Because Switched Mode Power Supply (SMPS) is higher in efficiency in the large capacity than Linear Regulator, it is used mainly and controls this in an analog form or digital method. A MCU and a DSP of the digital control central processing unit were higher in a unit price than existing analog control chip, so that an approach was not easy for application of SMPS. But it can take the earnings by it lets you integrate various digital control features like an LED illumination system in one MCU, and realizing a whole system. In this paper, we suggest the algorithm that can improve LED driving current in applying such a digital control method using low-priced type MCU.

An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp (초정압 방전램프(UCD)를 적용한 안전조명 장치에 관한 연구)

  • Jeong, Poong-Gi;Kim, Young-Chul
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.41-51
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

Accuracy and precision of integumental linear dimensions in a three-dimensional facial imaging system

  • Kim, Soo-Hwan;Jung, Woo-Young;Seo, Yu-Jin;Kim, Kyung-A;Park, Ki-Ho;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.45 no.3
    • /
    • pp.105-112
    • /
    • 2015
  • Objective: A recently developed facial scanning method uses three-dimensional (3D) surface imaging with a light-emitting diode. Such scanning enables surface data to be captured in high-resolution color and at relatively fast speeds. The purpose of this study was to evaluate the accuracy and precision of 3D images obtained using the Morpheus 3D$^{(R)}$ scanner (Morpheus Co., Seoul, Korea). Methods: The sample comprised 30 subjects aged 24.34 years (mean $29.0{\pm}2.5$ years). To test the correlation between direct and 3D image measurements, 21 landmarks were labeled on the face of each subject. Sixteen direct measurements were obtained twice using digital calipers; the same measurements were then made on two sets of 3D facial images. The mean values of measurements obtained from both methods were compared. To investigate the precision, a comparison was made between two sets of measurements taken with each method. Results: When comparing the variables from both methods, five of the 16 possible anthropometric variables were found to be significantly different. However, in 12 of the 16 cases, the mean difference was under 1 mm. The average value of the differences for all variables was 0.75 mm. Precision was high in both methods, with error magnitudes under 0.5 mm. Conclusions: 3D scanning images have high levels of precision and fairly good congruence with traditional anthropometry methods, with mean differences of less than 1 mm. 3D surface imaging using the Morpheus 3D$^{(R)}$ scanner is therefore a clinically acceptable method of recording facial integumental data.

Structural Analysis of Ag Agglomeration in Ag-based Ohmic Contact to p-type GaN (고분해능 X선 회절을 이용한 Ag 기반 p형 반사막 오믹 전극 집괴 분석)

  • Son, J.H.;Song, Y.H.;Lee, J.L.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.127-134
    • /
    • 2011
  • We investigate the crystallographic orientation and strain states of the Ni/Ag ohmic contacts on p-type GaN. The Ag film in the Ni/Ag contact was severely agglomerated during high temperature annealing in air ambient. As a results, after annealing for 24 h, the Ni/Ag contact shows non-linear I-V curve and low light reflectance of ~21% at 460 nm wavelength. High-resolution X-ray diffraction results show that the interplanar spacing of Ag (111) planes is almost same to that of bilk Ag after annealing for 24 hrs, indicating that the in-plane tensile strain in the Ag film was fully relaxed due to the Ag agglomeration.

Enhancement of Light Extraction in White LED by Double Molding (이중 몰딩에 의한 백색 LED의 광추출 효율 향상)

  • Jang, Min-Suk;Kim, Wan-Ho;Kang, Young-Rea;Kim, Ki-Hyun;Song, Sang-Bin;Kim, Jin-Hyuk;Kim, Jae-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.849-856
    • /
    • 2012
  • Chip on board type white light emitting diode on metal core printed circuit board with high thixotropy silicone is fabricated by vacuum printing encapsulation system. Encapsulant is chosen by taking into account experimental results from differential scanning calorimeter, shearing strength, and optical transmittance. We have observed that radiant flux and package efficacy are increased from 336 mW to 450 mW and from 11.9 lm/W to 36.2 lm/W as single dome diameter is varied from 2.2 mm to 2.8 mm, respectively. Double encapsulation structure with 2.8 mm of dome diameter shows further significant enhancement of radiant flux and package efficacy to 667 mW and 52.4 lm/W, which are 417 mW and 34.8 lm/W at single encapsulation structure, respectively.

Monochromatic Amber Light Emitting Diode with YAG and CaAlSiN3 Phosphor in Glass for Automotive Applications

  • Lee, Jeong Woo;Cha, Jae Min;Kim, Jinmo;Lee, Hee Chul;Yoon, Chang-Bun
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.1
    • /
    • pp.71-76
    • /
    • 2019
  • Monochromatic amber phosphor in glasses (PiGs) for automotive LED applications were fabricated with $YAG:Ce^{3+}$, $CaAlSiN_3:Eu^{2+}$ phosphors and Pb-free silicate glass. After synthesis and thickness-thinning process, PiGs were mounted on high-power blue LED to make monochromatic amber LEDs. PiGs were simple mixtures of 566 nm yellow YAG, 615 nm red $CaAlSiN_3:Eu^{2+}$ phosphor and transparent glass frit. The powders were uniaxially pressed and treated again through CIP (cold isostatic pressing) at 200 MPa for 20 min to increase packing density. After conventional thermal treatment at $550^{\circ}C$ for 30 min, PiGs were applied by using GPS (gas pressure sintering) to obtain a fully dense PiG plate. As the phosphor content increased, the density of the sintered body decreased and PiGs containing 30 wt% phosphor had full sintered density. Changes in photoluminescence spectra and color coordination were investigated by varying the ratio of $YAG/CaAlSiN_3$ and the thickness of the plates. Considering the optical spectrum and color coordinates, PiG plates with $240{\mu}m$ thickness showed a color purity of 98% and a wavelength of about 605 nm. Plates exhibit suitable optical characteristics as amber light-converting material for automotive LED applications.

Bactericidal Effect of a 275-nm UV-C LED Sterilizer for Escalator Handrails: Optimization of Optical Structure and Evaluation of Sterilization of Six Bacterial Strains

  • Kim, Jong-Oh;Jeong, Geum-Jae;Son, Eun-Ik;Jo, Du-Min;Kim, Myung-Sub;Chun, Dong-Hae;Kim, Young-Mog;Ryu, Uh-Chan
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.202-211
    • /
    • 2022
  • In the pasteurization of escalator handrails using ultraviolet (UV) sterilizers, a combination of light distribution and escalator speed has priority over other important factors. Furthermore, since part of the escalator handrail has a curved structure, proper design is needed to improve the sterilization rate on the surfaces touched by users. In this paper, two types of sterilizers satisfying these conditions are manufactured with 275-nm UV-C LEDs, after modeling the three-dimensional (3D) structure of an escalator handrail and simulating optical distributions of UV-C irradiation on the handrail's surface according to light-emitting diode (LED) positions and reflector variations in the sterilizers. Pasteurization experiments with the UV-C LED sterilizers are conducted on six types of gram-positive and gram-negative bacteria, with exposure times of 0.2, 5, and 15 s at an actual installation distance of 20 mm. The sterilization rates for the gram-positive bacteria are 10.63% to 27.94% at 0.2 s, 89.44% to 96.30% at 5 s, and 99.64% to 99.88% at 15 s. Those for the gram-negative bacteria are 57.70% to 77.63% at 0.2 s, 98.90% to 99.49% at 5 s, and 99.88% to 99.99% at 15 s. The power consumption of the UV-C LED sterilizer is about 8 W, which can be supplied by a self-generation module instead of an external power supply.

Attraction Effects of Sex Pheromone and LED Mass-Trap to Spodoptera exigua and Spodoptera litura (Fabricius) Adults around the Tomato Greenhouse (토마토 재배지 성페로몬 및 LED 유인 트랩을 이용한 파밤나방(Spodoptera exigua)과 담배거세미나방(Spodoptera litura) 대량 포획)

  • Lee, Jung Sup;Bang, Ji Wong;Lee, Jae Han;Jang, Hye Sook
    • Journal of Bio-Environment Control
    • /
    • v.31 no.1
    • /
    • pp.22-27
    • /
    • 2022
  • The attraction effects of light emitting diode (LED) trap to Spodoptera exigua and Spodoptera litura adults were evaluated in greenhouse and compared with those of no light trap, which is typical used in commercial trap. At this time, in order to attract these two species of moths, sex pheromone traps were installed at the top side according to the degree of tomato growth inside the tomato cultivation greenhouse around the LED trap. In addition, two types of light-emitting traps (420 nm, 470 nm) were installed in the greenhouse at 1/40 m2, respectively. Also two sex pheromone were installed inside of the greenhouse according to the height of the tomato plants. 10 days later, Blue-light trap(BLB, 470 nm wavelength) was 3.1-3.5 times more attractive than Violet-light trap(VLB, 420 nm wavelength) in S. exigua (105.6 ± 7.3) and S. litura (42.0 ± 3.1) respectively, whereas the no-light trap was little attractive to S. exigua (33.7 ± 2.8) and S. litura (12.0 ± 1.5). On the other hand, after the installation of the sex pheromone trap and the LED trap, there was no damage to S. litura (Fabricius) and S. exigua in the pesticide-free area, indicating a high possibility of control. At this time, the operating cost of the two types of LED traps was 80 won/m2 per unit area, and it was confirmed that both types of moths could be controlled. In addition, as a result of confirming the number of two types of moths caught in the sexual pheromone trap and two types of LED traps after 4 months, it was judged that eco-friendly control was possible as more than 373 moths/trap were attracted to the two types of moths.