Bactericidal Effect of a 275-nm UV-C LED Sterilizer for Escalator Handrails: Optimization of Optical Structure and Evaluation of Sterilization of Six Bacterial Strains |
Kim, Jong-Oh
(Printed Electronics Technology Research Center, Pukyong National University)
Jeong, Geum-Jae (Department of Food Science and Technology, Pukyong National University) Son, Eun-Ik (Department of Food Science and Technology, Pukyong National University) Jo, Du-Min (Department of Food Science and Technology, Pukyong National University) Kim, Myung-Sub (ACRO Co.) Chun, Dong-Hae (ACRO Co.) Kim, Young-Mog (Department of Food Science and Technology, Pukyong National University) Ryu, Uh-Chan (Interdisciplinary Program of LED and Solid-State Lighting Engineering, Pukyong National University) |
1 | J. O. Kim, G. J. Jeong, E. I. Son, D. H. Chun, M. S. Kim, and U.-C. Ryu, "A study on the optical structure and sterilization evaluation of UV C LED sterilizer of escalator handrail," in Proc. KIIEE Annual Spring Conference and General Meeting, (GangWon-do, Korea, May 12-14, 2021), paper 1-A-2. |
2 | D. R. Bhatta, D. Hamal, R. Shrestha, S. H. Subramanya, N. Baral, R. K. Singh, N. Nayak, and S. Gokhale, "Bacterial contamination of frequently touched objects in a tertiary care hospital of Pokhara, Nepal: how safe are our hands," Antimicrob. Resist. Infect. Control 7, 97 (2018). DOI |
3 | M. Berney, H.-U. Weilenmann, and T. Egli, "Adaptation to UVA radiation of E.coli growing in continuous culture," J. Photochem. Photobiol. B: Biol. 86, 149-159 (2007). DOI |
4 | Y. W. Lee, H. D. Yoon, J.-H. Park, and U.-C Ryu, "Application of 265-nm UVC LED lighting to sterilization of typical gram negative and positive bacteria," J. Korean Phys. Soc. 72, 1174-1178 (2018). DOI |
5 | W. A. Rutala and D. J. Webber, "Infection control: the role of disinfection and sterilization," J. Hosp. Infect. 43, S43-S55 (1999). DOI |
6 | M. Raeiszadeh and B. Adeli, "A critical review on ultraviolet disinfection systems against COVID-19 outbreak: applicability, validation, and safety considerations," ACS Photonics 7, 2941-2951 (2020). DOI |
7 | J. Z. Brook and I. Brook, "Recovery of organisms from the handrails of escalators in the public metro rail system in Washington D.C.," J. Environ. Health. 57, 13-15 (1994). |
8 | G. Cheverfils, E. Caron E, H. Wrigth, G. Sakamto, P. Payment, B. Barbeau, and B. Carins, "UV dose required to achieve incremental log inactivation of bacteria, protozoa and viruses," IUVA News 8, 38-45 (2006). |
9 | A.-C. Chevremont, A.-M. Farnet, B. Coulomb, and J.-L. Boudenne, "Effect of coupled UV-A and UV-C LEDs on both microbiological and chemical pollution of urban wastewaters," Sci. Total Environ. 426, 304-310 (2012). DOI |
10 | P. O. Nyangaresi, Y. Qin, G. Chen, B. Zhang, Y. Lu, and L. Shen, "Comparison of the performance of pulsed and continuous UVC-LED irradiation in the inactivation of bacteria," Water Res. 157, 218-227 (2019.) DOI |
11 | M. Mori, A. Hamamoto, A. Takahashi, M. Nakano, N. Wakikawa, S. Tachibana, T. Ikehara, Y. Nakaya, M. Akutagawa, and Y. Kinouchi, "Development of a new water sterilization device with a 365 nm UV-LED," Med. Biol. Eng. Comput. 45, 1237-1241 (2007). DOI |
12 | M. P. Muller, C. MacDougall, M. Lim, and Ontario Agency for Health Protection and Promotion (Public Health Ontario), "Antimicrobial surfaces to prevent healthcare-associated infections: a systematic review," J. Hosp. Infect. 92, 7-13 (2016). DOI |
13 | J. S. Do and W. S. Bang, "Bactericidal effect of 461 nm blue light emitting diode on pathogenic bacteria," Korean J. Food Preserv. 20, 419-423 (2013). DOI |
14 | T. Assefa, H. Tasew, B. Wondafrash, and J. Beker, "Assessment of bacterial hand contamination and associated factors among food handlers working in the student cafeterias of Jimma Main Campus, Jimma, South West Ethiopia," J. Community Med. Health Educ. 5, 1000345 (2015). |
15 | S.-K. Park, D.-M. Jo, M.-G. Kang, F. Khan, S. D. Hong, C. Y. Kim, Y.-M. Kim, and U.-C. Ryu, "Bactericidal effect of ultraviolet C light-emitting diodes: Optimization of efficacy toward foodborne pathogens in water," J. Photochem. Photobiol. B: Biol. 222, 112277 (2021). DOI |
16 | J. O. Kim, S. K. Park, D. M. Jo, G. J. Jeong, E. I. Son, D. H. Chun, M. S. Kim, and U.-C. Ryu, "A study on optical simulation of UV C sterilizer for escalator handrail," in Proc. OSK Annual Meeting (Virtual Conference, Feb. 17-19, 2021), CD, paper WP-II-20. |
17 | C. K. Mok and N. H. Lee, "Distribution of ultraviolet intensity and UV leaking of commercial UV sterilizers used in restaurants," Korean J. Food Sci. Technol. 40, 228-233 (2008). |
18 | J. H. Kim, J. I. Band, A. S. Choi, and M. K. Sung, "An analysis on the effect of mold sterilization in apartment using 405 nm visible light LED," J. Korean Inst. Archit. Sust. Environ. Buil. Sys. 13, 590-598 (2019). |
19 | J. K. Hong, "Experimental study on the irradiation and surface sterilization effect of ultra violet ray in air conditioning system," Korean J. Air-Cond. Refrig. Eng. 16, 250-258 (2004). |
20 | K. S. Ismail, "A preliminary study of bacterial contamination from elevators," Inter. J. Sci. Res. 2, 1-2 (2013). DOI |
21 | S. A. Malik, T. T. Swee, N. A. N. N. Malek, M. R. A. Kadir, T. Emoto, M. Akutagawa, L. K. Meng, T. J. Hou, and T. A. I. T. Alang, "Comparison of standard light-emitting diode (LED) and 385 nm ultraviolet A LED (UVA-LED) for disinfection of Escherichia coli," Mal. J. Fund. App. Sci. 4, 430-437 (2017). |
22 | Y. Ahmadi, N. Bhardwaj, K.-H. Kim, and S. Kumar, "Recent advances in photocatalytic removal of airborne pathogens in air," Sci. Total Environ. 794, 148477 (2021). DOI |