• Title/Summary/Keyword: Light marker

Search Result 96, Processing Time 0.024 seconds

Marker Recognition System for the User Interface of a Serious Case (중증환자 인터페이스를 위한 마커 인식 시스템)

  • So, In-Mi;Kang, Sun-Kyung;Kim, Young-Un;Jung, Sung-Tae
    • The KIPS Transactions:PartB
    • /
    • v.14B no.3 s.113
    • /
    • pp.191-198
    • /
    • 2007
  • In this paper, we present a marker detection and recognition method from camera image for a disabled person to interact with a server system which can control appliance of surrounding environment. It converts the camera image to a binary image by using multi-threshold and extracts contours of objects in the binary image. After that, it approximates the contours to a list of line segments. It finds rectangular markers by using geometrical features which are extracted from the approximated line segments. It normalizes the shape of extracted markers into exact squares by using the warping technique. It extracts feature vectors from marker image by using principal component analysis and then recognizes the marker. The proposed marker recognition system is robust for light change by using multi-threshold. Also, it is robust for angular variation of camera by using warping technique and principal component analysis. Experimental results show that the proposed method achieves 100% recognition rate at maximum for 21 markers and execution speed of 12 frames/sec.

Effect of Light on Development of Microbody Functions in the Cotyledons of Rape (Brassica napus L.) Seedlings (유채 종자의 Microbody 기능 발달에 미치는 빛의 영향)

  • 피문자
    • Journal of Plant Biology
    • /
    • v.25 no.2
    • /
    • pp.73-81
    • /
    • 1982
  • The changes in activities of glyoxysomal and peroxisomal enzymes during the transition from fat degradation to photosynthesis were investigated with the cotyledns of rape (Brassica napus L.) seedlings. The development and disappearance of glyoxysomal enzyme (isocitrate lyase, EC 4.1.3.1; malate dehydrogenase, EC 1.1.1.37; catalase, EC 1.11.1.6) activities took place independently of light. It is concluded that the mobilization of storage fat is independent of photomorphogenesis. During early periods of development in the dark of light (days 1 through 3), the glyoxysomal enzyme activities were relatively high and the enzyme activities rose to a peak at 3rd day after sowing. Thereafter, the activities decreased gradually. While glyoxysomal enzyme activities were dropping, the peroxisomal enzyme (glycolate oxidase, EC 1.1.3.1) activities were increasing rapidly during the transition period in the light. Moreover, the changes of enzyme activities of the common microbody marker, catalase, indicated both functional patterns. The enzyme patterns in rape cotyledons indicate that the glyoxysomal function of microbodies is replaced by the peroxisomal function of these organelles during the transition from fat degradation to photosynthesis.

  • PDF

Design of Mixed Reality based Convergence Edutainment System using Cloud Service (클라우드 서비스를 이용한 복합현실 기반의 융합형 에듀테인먼트 시스템 설계)

  • Kim, Donghyun;Kim, Minho
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.3
    • /
    • pp.103-109
    • /
    • 2015
  • TOLED(Transparent, Organic Light Emitting Diodes) based edutainment system has been studied to solve the actual feeling training and educational experience problem of e-learning. However, edutainment system using TOLED has a problem for the non-detection of multi marker array and rotate marker array, and it has problem for the dissonance phenomena caused by Illumination Environment between real world and virtual object. It also has a do not provide services through a variety of devices problem. Therefore, in this paper, we designed a system that provides a realistic actual feeling edutainment contents by recognizes the marker array rotation and a plurality of marker arrangement via an improved marker detection technique. And to unify the real space and virtual space of the lighting environment through a nested block layer.

A Boundary-based Marker Binary Coding Method for Augmented Reality Games (증강현실 게임을 위한 경계선 기반 마커 이진화 방법)

  • Yun, Yo-Seop;Kim, Tae-Young
    • Journal of Korea Game Society
    • /
    • v.10 no.4
    • /
    • pp.63-71
    • /
    • 2010
  • In this paper, we propose a boundary based marker binary coding method for augmented reality games, which enables the marker-area to be binary coded well in any lighting environments. First, it detects the boundary after transforming an original marker image to a gray scale image, and it executes 4 way pixel extensions for all boundary pixels in order to make the boundary to closed area. Next, for all boundary pixels it compares the brightness of right and left ones of each pixel and allocates black for the lower side and white for the higher side by filling inside area thru the seeded region growing. Experimental results showed that our proposed method produces a good binary marker image recognizable in various light environments. In addition, it showed the possibility of real-time calculation by considering the result of operation speed which is 51 fps for VGA image.

Changes of superoxide dismutase and glutathione peroxidase in light damaged rat retina

  • Kaidzu, Sachiko;Tanito, Masaki;Takanashi, Taiji;Ohira, Akihiro
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.430-432
    • /
    • 2002
  • The changes in expression of copper-zinc superoxide dismutase (CuZn-SOD), manganese superoxide dismutase (Mn-SOD) and glutathione peroxidase (GPX) in light-damaged rat retinas were examined. Sprague-Dawley rats (male, 6-weeks-old) were maintained on a cyclic photoperiod (12 hours light and 12 hours darkness) for 2 weeks. The illumination intensity during the light period was 80 lux. To induce light damage to the retina, a high-intensity illumination (3000-lux) was applied to the animals for 24 hours. After light exposure, the animals were returned to cyclic lighting. Eyes were enucleated 12 and 24 hours after light exposure started or 1,3, and 7 days after light exposure ended. Eyes were fixed and embedded in paraffin wax. Tissues were cut into 4${\mu}{\textrm}{m}$-thick sections. Sections were immunostained using antibody against CuZn-SOD, Mn-SOD, GPX and 8-hydroxy-deoxyguanocine (8-OHdG) as oxidative stress marker. 8-OHdG was observed in the outer nuclear layer (ONL) and retinal pigment epithelium (RPE) during light exposure. In light-damaged retinas CuZn-SOD labeling was up regulated in the ONL and RPE. Mn-SOD labeling was up regulated in rod inner segments (RIS) during light exposure and that in the RPE was up regulated after exposure. GPX labeling was observed in rod outer segments (ROS) during light exposure. GPX labeling was also observed in the RPE during and after light exposure. All three enzymes were observed in the outer retina, which suffered light damage, but occurred in defferent layers except within the RPE, in which case all three were expressed. These enzymes may play complementary roles as protective factors in light-damaged retinas.

  • PDF

One-Step Engineering of a Stable, Selectable Marker-Free Autoluminescent Acinetobacter baumannii for Rapid Continuous Assessment of Drug Activity

  • Jiang, Huofeng;Gao, Yamin;Zeng, Sheng;Wang, Shuai;Cao, Zhizhong;Tan, Yaoju;Yin, Huancai;Liu, Jianxiong;Zhang, Tianyu
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.9
    • /
    • pp.1488-1493
    • /
    • 2019
  • The rising cases of multidrug-resistant Acinetobacter baumannii (Ab) and the lack of effective drugs call for quick attention. Here, based on a Tn7 transposon and Xer/dif system, we constructed a stable, selectable marker-free autoluminescent Ab capable of producing visible light without extra substrates. Utilization of this autoluminescent reporter strain has the potential to reduce the time, effort and costs required for the evaluation of activities of anti-Ab drug candidates in vitro.

A Study on the Sensor Calibration of Motion Capture System using PSD Sensor to Improve the Accuracy (PSD 센서를 이용한 모션캡쳐센서의 정밀도 향상을 위한 보정에 관한 연구)

  • Choi, Hun-Il;Jo, Yong-Jun;Ryu, Young-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.583-585
    • /
    • 2004
  • In this paper we will deal with a calibration method for low cost motion capture system using psd(position sensitive detection) optical sensor. To measure the incident direction of the light from LED emitted marker, the PSD is used the output current ratio on the electrode of PSD is proportional with the incident position of the light focused by lens. In order to defect the direction of the light, the current output is converted into digital voltage value by opamp circuits peak detector and AD converter with the digital value the incident position is measured. Unfortunately, due to the non-linearly problem of the circuit poor position accuracy is shown. To overcome such problems, we compensated the non-linearly by using least-square fitting method. After compensated the non-linearly in the circuit, the system showed more enhanced position accuracy.

  • PDF

Development of polymorphism genetic marker for identification of the silkworm races (누에 피브로인 유전자 다형성 마커 개발)

  • Choi, Kwang-Ho;Kim, Seong-Ryul;Kang, Seok-Woo;Piao, Yulan;Kim, Sung-Wan;Kim, Kee-Young
    • Journal of Sericultural and Entomological Science
    • /
    • v.53 no.2
    • /
    • pp.124-129
    • /
    • 2015
  • We have previously characterized the complete fibroin light chain gene from one of the silkworm race Baegokjam (Bombyx mori) and found two variable regions (FibL1, intron 2 ~ 3; FibL2, intron 6) with the primer sets designed to cover these variable regions. In this study, we tested the utility of these variable regions as genetic markers for classifying silkworm races. For the purpose, Europian races (Q, PK), Chinese races (C26, C31), Japanese races (N15, N9), and tropical races (SA2, SA5) were used in this experiment. The polymorphism of the FibL1 and FibL2 were divided into two and three types, respectively. The combination of the FibL1 and FibL2 polymorphisms were constant within the same races. The result suggest that the primer sets designed from two variable regions of fibroin light chain gene may be useful as the genetic markers for silkworm races.

Motion analysis system using image processing (화상처리를 이용한 동작분석 시스템에 관한 연구)

  • 박경수;반영환;이안재;임창주;오인석;이현철
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.71-75
    • /
    • 1997
  • This paper presents the development of videobased 3-dimensional tracking system. Measurement of human motion is important in the application of ertonomics. The system uses advanced direct video measurement technology. Passive retro-reflecting markers are attached to a subject and movements of markers are observed by two CCD cameras. Infrared light emitted near the CCD cameras is reflected by the markers and is detected by the cameras. The images are captured by Samsung MVB302 board and the centers of markers are calculated by DSP program. The positions of markers are transferred from MVB02 board to the computer through AT bus. The computer then tracks the position of each marker and saves the data. This system has dynamic accuracy with 0.7% average error and 4.2% maximum error, and the sampling rate to 6 .approx. 10 Hz, and this system can analyse the trajectory and speed of the marker. The results of this study can be used for operator's motion analysis, task analysis, and hand movement characteristic analysis.

  • PDF

Video-based 3-dimensional tracking system (영상을 이용한 3차원 위치 추적 시스템 개발1)

  • 박경수;반영환;이안재;임창주
    • Proceedings of the ESK Conference
    • /
    • 1996.10a
    • /
    • pp.160-165
    • /
    • 1996
  • This paper presents the development of video-based 3-dimensional tracking system. Measurement of human motion is important in the application of ergonomics. The system uses advanced direct video measurement technology. Passive retro-reflecting markers are attached to a subject and movements of markers are observed by two CCD cameras. Infrared light emitted near the CCD cameras is reflected by the markers and is detected by the cameras. The image ae captured by Samsung MVBO2 board and the center of markers is calculated by DSP program. The position of markers are transferred from MVB02 board to the computer through AT bus. The computer then tracks the position of each marker and saves the data. This system has dynamic accuracy with 1% error and the sampling rate to 6-10 Hz, and can analyse the trajectory and speed of the marker. The results of this study can be used for operators motion analysis, task analysis, and hand movement characteristic analysis.

  • PDF