Image Detection System for leakage regions of Hydraulic Fluid in Foring Press Machine (단조프레스기의 유압유 누유 영역 영상 감지 시스템)

  • Lee, Kyeong-Hwan;Bae, Sung-Ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.35-39
    • /
    • 2009
  • In the hydraulic room of a forging press machine, a system which can detect and prevent risks at its early stage is needed because there may be a leakage due to the damage of the connection parts of the piping which can endanger human life and mechanical damage. In this paper, the system to automatically recognize a leakage of hydraulic fluid by the pan/tilt camera from a remote place is implemented. It finds the Minimum Boundary Rectangles(MBR) which are recognized with candidate leakage regions in the process of labeling and detects the proper leakage regions of hydraulic fluid with the width and height of MBRs and the area ratios of the MBRs and the candidate leakage regions. The experimental results show that the proposed system has been verified to detect the leakage regions accurately in various light conditions.

  • PDF

A Study on the Effect of. Oil Leakage for Soil Contamination, Plants and Groundwater (오일의 누출이 토양오염, 식생 및 지하수에 주는 영향에 관한 연구)

  • 진성기;도덕현;최규홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.1
    • /
    • pp.141-152
    • /
    • 1994
  • Our experiment investigated the degree of soil contaimination caused by oil leakage. Each soil sample was taken by boring 5, 8m below the test areas, located 5 to 30m from storage tanks at oil stations. According to the results from a series of laboratory tests(both soxhiet extract test and gas chromatograph test), Traces of a light oil were found in all samples except in Dj8, rocky soil and gasoline and petroleum were not detected. We concluded that soil contamination was caused by the corrosion of storage tanks or alternatively by oil overflow caused during the flooding of underground water seeping into the tank during heavy rain fall or the spillage caused by carelessness during lubrication. Old stations without a concrete box enclosing their metal tanks run a greater risk of oil leakage. To research the effect of oil leakage on plant growth and underground water, We examined the results of research conducted overseas. According to these results, when oil leakage occurs, plant growth is repressed and agricultural crops experience low productivity levels. Also, the contamination of underground water can be serious when oil spreads to the aquifer layer. As a result of these problems, to prevent oil leakage and minimize its contaminating effects at oil stations, it is necessary to improve facilities of storage tanks and have the monitoring system of oil leakage.

  • PDF

Properties of Surface Electrical Conduction in Materials for Outdoor Insulator (옥외 애자용 재료의 표면 전기전도특성)

  • 박영국;강성화;정수현;이운석;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.207-210
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition. The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

Evaluation of green light Emitting diode with p-type GaN interlayer (P형 GaN 중간층이 삽입된 녹색 발광다이오드 특성 평가)

  • Kim, Eunjin;Kim, Jimin;Jang, Soohwan
    • Korean Chemical Engineering Research
    • /
    • v.54 no.2
    • /
    • pp.274-277
    • /
    • 2016
  • Effects of interlayer insertion between multi-quantum well and electron blocking layer of green light emitting diode on diode performances were studied by device simulation. Dependence of Mg doping depth on characteristics of current-voltage, emitting wavelength, leakage current, and external quantum efficiency was investigated, and the optimum diode structure was presented. Device structures with interlayers doped in entire region and up to 30 nm showed remarkable reduced leakage current and effectively relieved efficiency droop which is one of the biggest challenges in green light emitting diode. Furthermore, the most improved characteristics in current-voltage and electroluminescence was obtained by the latter structure.

Analysis of Deep-Trap States in GaN/InGaN Ultraviolet Light-Emitting Diodes after Electrical Stress

  • Jeong, Seonghoon;Kim, Hyunsoo;Lee, Sung-Nam
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1879-1883
    • /
    • 2018
  • We analyzed the deep-trap states of GaN/InGaN ultraviolet light-emitting diodes (UV LEDs) before and after electrical stress. After electrical stress, the light output power dropped by 5.5%, and the forward leakage current was increased. The optical degradation mechanism could be explained based on the space-charge-limited conduction (SCLC) theory. Specifically, for the reference UV LED (before stress), two sets of deep-level states which were located 0.26 and 0.52 eV below the conduction band edge were present, one with a density of $2.41{\times}10^{16}$ and the other with a density of $3.91{\times}10^{16}cm^{-3}$. However, after maximum electrical stress, three sets of deep-level states, with respective densities of $1.82{\times}10^{16}$, $2.32{\times}10^{16}cm^{-3}$, $5.31{\times}10^{16}cm^{-3}$ were found to locate at 0.21, 0.24, and 0.50 eV below the conduction band. This finding shows that the SCLC theory is useful for understanding the degradation mechanism associated with defect generation in UV LEDs.

A STUDY ON THE COMPATIBILITY OF DENTIN ADHESIVES WITH COMPOSITE RESINS (수종의 상아질 접착제와 복합레진의 적합성에 관한 연구)

  • Park, Jin-Sung;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.214-234
    • /
    • 1995
  • The purpose of this work was to study the compatibility of several commercially available dentin adhesives with composite resins. In this study, V-shaped cavity preparations were created on both buccal and lingual surfaces of 60 extracted human premolars($3mm{\times}3mm{\times}2mm$ deep). Preparations were located such that the occlusal margins were on the enamel and the gingival margins were on the cementum(1mm below the CEJ). These specimens were randomly divided into three equal groups. Three dentin adhesives(Scotchbond Multi-Purpose, All Bond 2, Prisma Universal Bond 3)were applied to the cavity in accordance with each manufacturer's instructions. The teeth in each group were restored with four composite resins(Silux plus, Z100, Bisfil, Prisma TPH) in three increments, with each increment light-cured for 40 seconds. All specimens were exposed to 500 cycles of thermal stress. Specimens then placed in a silver nitrate solution(50% by weight) and stored in darkness for 24 hours. They were then immersed for 6 hours in photographic developing solution under flourescent light. Specimens were sectioned buccolingually through the center of the restoration and observed under a binocular stereoscope. To compare the marginal leakage, ANOVA and Dunkan's multiple range tests were used in analysis. Selected samples were further studied using scanning electron microscopy(XL20, Philips, The Netherlands). The results were as follows. 1. In all groups, the enamel margin showed significantly less leakage than the cementum margin. 2. No statistically significant differences were found in microleakage when composite resins were used with their proprietary dentin adhesives. 3. In comparison between dentin adhesives, Prisma Universal Bond 3 showed significantly less leakage at the enamel margin and Scotch bond multi-purpose showed significantly less leakage at the cementum margin than the other groups. 4. In comparison between composite resins, Silux Plus showed significantly more leakage than other groups at the enamel margin and no statistically significant differences were found in microleakage at the cementum margin. 5. According to the backscattered scanning electron microscope, microleakage occurred via gaps at the dentin adhesives/dentin interface.

  • PDF

Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology (Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가)

  • Kim, Eun-Ji;Lee, Kyu-Bok;Jin, Myoung-Uk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.

An Experimental Study on Microleakage in Light-activated Temporary Filling Materials (광중합형 임시충전재의 미세누출에 관한 실험연구)

  • Hwang, Su-Hyun;Yu, Ji-Su;Kim, Sun-Ju
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.333-337
    • /
    • 2011
  • The purpose of this experiment was to examine possibility of microleakage by water, temperature change, and bite force inside the mouth during the period of using light-activated temporary filling materials. 2 kinds of light-activated temporary filling materials were used in order to measure weight and compressive strength and to evaluate microleakage between filling material and cavity wall according to frequency of thermal circulation. First, Light-activated temporary filling material was increased the weight, which was measured according to the period of using. As for the result of comparing between products, the weight of Quicks was indicated to be higher. Second, Compressive strength of Spacer had significant difference depending on period of using. However, significant difference wasn't shown in the compressive strength of Quicks. In Spacer that showed significant difference, the compressive strength increased greatly in the difference of 3 days. Third. As for micro-leakage according to frequency of thermal circulation, the microleakage was indicated to be the highest in the group that carried out 7,000 times. The group with operation of 1,000 times and the group with operation of 3,000 times were indicated the statistically lower micro-leakage than the group with operation of 7,000 times. This study brought about a rise in micro-leakage depending on the passage in the period of using. However, it is obvious fact that micro-leakage increases according to the passage of time after restoration.

Properties of PD Pulses accompanying with propagation of Bush-type tree in LDPE (LDPE에서 부시형 전기트리의 성장에 수반되는 부분방전 펄스의 특성)

  • 박영국;강성화;정수현;박철현;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.293-296
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition, The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level. the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

A STUDY ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN (복합(複合) resin의 변록누출(邊綠漏出)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Cho, Jin-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.131-138
    • /
    • 1981
  • The purpose of this study was to evaluate the marginal leakage of composite resin. Preparing 144 class V cavities on freshly extracted noncarious teeth, composite resins were prepared and inserted by one dentist according to the manufacturer's instructions. The experiments were performed in two different groups; In group I; Class V cavities with $90^{\circ}$ cavosurface angle, In group II; Class V cavities with $135^{\circ}$ cavosurface angle. And each group was divided 2 subgroups; In control group; composite resin restoraions without acid etch technique. In experimental group; composite resin restorations with acid etch technique. All specimens were immersed in 0.05% crystal violet solution. Before examination, the restored teeth were subjected to thermal stress. The specimens were sectioned occlusogingivally through the center of the restorations with a diamond disk. The sections were examined under a reflected light microscope at 1 day, 7 days and 30 days after immersing the specimens in dye solution. The results were as follows; 1. Control group of group I and group II showed marginal leakage. 2. The degree of marginal leakage in experimental group was greater reduced than control group. 3. In control group, the degree of marginal leakage in group I was greater than group II. 4. In experimental group, there is not statistical differences of the degree of marginal leakage between group I & group II.

  • PDF