• Title/Summary/Keyword: Li Chan

Search Result 314, Processing Time 0.027 seconds

Effects of Aqueous Extract of Schizandrae Fructus on Lead-Induced Change of Monoamine Neurotransmitters in Hippocampus

  • Zhao, Rong Jie;Zhao, Zheng Lin;Zhao, Xiu Feng;Zhao, Guang Wen;Li, Meng Quan;Wu, Yi Yan;Li, Jing Qiu;Guan, Li Xin;Kim, Sang-Chan
    • Herbal Formula Science
    • /
    • v.17 no.2
    • /
    • pp.143-150
    • /
    • 2009
  • The effects of aqueous extract of Schizandrae Fructus (AESC) on lead (Pb)-induced changes of monoamine neurotransmitters in the hippocampus (HIP) of adult rats were investigated. Male Sprague-Dawley rats were received intraperitoneal (i.p.) administration of Pb acetate (5 mg/kg/d) for 28 days and sacrificed 7 days after the last administration. Concentrations of norepinephrine (NE), dopamine (DA), serotonin (5-HT), 5-hydroxyindole acetic acid (5-HIAA) in HIP were measured by HPLC. There were significant decreases of NE, DA, 5-HT and 5-HIAA in Pb treated rats (P < 0.05), while pretreatment with AESC (100 mg/kg/d or 300 mg/kg/d, p.o., 2 h before Pb) greatly inhibited the decrease of monoamine transmitters, respectively (P < 0.05). Also, AESC (300 mg/kg/d) significantly increased the reduction of glutathione contents and superoxide dismutase activities in HIP induced by chronic Pb. These results suggest that AESC ameliorates Pb-induced depletion of monoamine neurotransmitters in HIP through its antioxidant activity.

  • PDF

Lithium Ion Concentration Dependant Ionic Conductivity and Thermal Properties in Solid Poly(PEGMA-co-acrylonitrile) Electrolytes

  • Kim, Kyung-Chan;Roh, Sae-Weon;Ryu, Sang-Woog
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.57-62
    • /
    • 2010
  • The lithium ion concentration dependant ionic conductivity and thermal properties of poly(ethylene glycol) methyl ether methacrylate (PEGMA)/acrylonitrile-based copolymer electrolytes with $LiClO_4$ have been studied by differential scanning calorimetry (DSC), linear sweep voltammetry (LSV) and AC complex impedance measurements. In systems with 11 wt% of acrylonitrile all liquid electrolytes were obtained regardless of lithium ion concentration. Complex impedance measurements with stainless steel electrodes give ambient ionic conductivities $8.1\times10^{-6}\sim1.4\times10^{-4}S cm^{-1}$. On the other hand, a hard and soft films at ambient temperature were obtained in copolymer electrolyte system consists of 15 wt% acrylonitrile with 6 : 1 and 3 : 1 of [EO] : [Li] ratio, respectively. DSC measurements indicate the crystalline melting temperature of poly(PEGMA) disappeared completely after addition of $LiClO_4$ in this system due to the complex formation between ethylene oxide (EO) unit and lithium salt. As a result, free standing film with room temperature ionic conductivity of $1.7\times10^{-4}S cm^{-1}$ and high electrochemical stability up to 5.5V was obtained by controlling of acrylonitrile and lithium salt concentration.

Germanium Nanoparticle-Dispersed Reduced Graphene Oxide Balls Synthesized by Spray Pyrolysis for Li-Ion Battery Anode

  • Kim, Jin Koo;Park, Gi Dae;Kang, Yun Chan
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.1
    • /
    • pp.65-70
    • /
    • 2019
  • Simple fabrication of a powdered Ge-reduced graphene oxide (Ge-rGO) composite via spray pyrolysis and reduction is introduced herein. Successful incorporation of the rGO nanosheets with Ge hindered the aggregation of Ge and conferred enhanced structural stability to the composite by alleviating the mechanical stress associated with drastic volume changes during repeated cycling. The Li-ion storage performance of Ge-rGO was compared with that of powdered Ge metal. The reversible discharge capacity of Ge-rGO at the $200^{th}$ cycle was $748mA\;h\;g^{-1}$ at a current density of $1.0A\;g^{-1}$ and Ge-rGO showed a capacity of $375mA\;h\;g^{-1}$ even at a high current density of $5.0A\;g^{-1}$. The excellent performance of Ge-rGO is attributed to the structural robustness, enhanced electrical conductivity, and formation of open channels between the rGO nanosheets, which facilitated electrolyte penetration for improved Li-ion diffusion.

Effect of Al and Nb Doping on the Electrochemical Characteristics of Garnet-type Li7La3Zr2O12 Solid Electrolytes

  • Ahmed Tarif;Chan-Jin Park
    • Corrosion Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.408-418
    • /
    • 2023
  • In this study, we synthesized and characterized garnet-type Li7-xAlxLa3Zr2-(5/4)yNbyO12 (LALZN) solid electrolytes for all-solid-state battery applications. Our novel approach focused on enhancing ionic conductivity, which is crucial for battery efficiency. A systematic examination found that co-doping with Al and Nb significantly improved this conductivity. Al3+ and Nb5+ ions were incorporated at Li+ and Zr4+ sites, respectively. This doping resulted in LALZN electrolytes with optimized properties, most notably enhanced ionic conductivity. An optimized mixture with 0.25 mol each of Al and Nb dopants achieved a peak conductivity of 1.32 × 10-4 S cm-1. We fabricated symmetric cells using these electrolytes and observed excellent charge-discharge profiles and remarkable cycling longevity, demonstrating the potential for long-term application in battery systems. The garnet-type LALZN solid electrolytes, with their high ionic conductivity and stability, show great potential for enhancing the performance of all-solid-state batteries. This study not only advances the understanding of effective doping strategies but also underscores the practical applicability of the LALZN system in modern energy storage solutions.

Supratentorial Intraparenchymal Haemorrhages during Spine Surgery

  • Leung, Gilberto Ka Kit;Chan, Johnny Ping Hon
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.2
    • /
    • pp.103-105
    • /
    • 2014
  • Intracranial haemorrhages are rare but potentially life-threatening complications of spine surgery. Most reported cases involved subdural or cerebellar haemorrhages; supratentorial parenchymal bleeding is very uncommon. We report a 28-year-old woman who underwent resection of a thoracic Ewing's sarcoma, and developed fatal haemorrhages around her cerebral metastases during surgery. The clinical presentations, possible pathogenesis and potential preventive measures are discussed. Patients with disseminated metastases within the neural axis are at risks of intracranial complications during spine surgery. The presence of intracranial mass lesions should be considered as a relative contraindication to intradural spine surgery.

Intraventricular Atypical Meningiomas

  • Kim, Hyun-Doo;Choi, Chan-Young;Lee, Dong-Joon;Lee, Chae-Heuck
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.5
    • /
    • pp.292-295
    • /
    • 2011
  • A rare case of intraventricular meningioma that arose in the atrium of the left lateral ventricle was identified in a 51-year-old woman. Gross total removal was performed by transcortical approach. Histopathological findings showed meningothelial meningioma with a focal atypical area which had 8% of Ki-67 labeling index (LI). A large recurrence extending into the ipsilateral quadrigeminal cistern and opposite medial occipital lobe developed approximately 41 months after the first operation. The specimens obtained from the second resection showed atypical meningioma with 20% of Ki-67 LI but there were no anaplastic area. The patient underwent fractionated stereotactic radiotherapy. However, multiple local distant metastases were found in the occipital and cerebellar cortex suggesting cerebrospinal fluid dissemination apparently 24 months after the second operation. This report presents chronological progression of a rare intraventricular atypical meningioma with more aggressive transformation.

Determination of Microamounts of Copper by Fluorescence X-Ray Analysis (형광 X-선 분석에 의한 미량 구리의 정량)

  • Choi Won-hyung;Kim Chan-ho
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.6
    • /
    • pp.373-377
    • /
    • 1972
  • The analytical conditions for the fluorescence X-ray determination of small amount of cupper in solution were established. Copper in solution was extracted by diethyldithiocarbamate ethyl acetate and adsorbed by zinc powder. After drying, it was pressed to tablet under the pressure of $250Kg/cm^2.$$K_{\alpha}2(2{\theta}_{LiF} = 45.08^{\circ})$. The limit of detection was estimated to be about $10{\mu}g$ by the method of standard addition with an error of 10 %.

  • PDF

The study of High Efficiency Cycle Characteristics of the absorption Chiller (흡수식 냉동기 고효율화를 위한 사이클 설계)

  • Park, Chan-U
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.534-539
    • /
    • 2007
  • The objectives of the present work is to investigate the influence of the solution cooled absorber(SCA), refrigerant drain heat exchanger(RSX), exhaust gas/solution heat exchanger(ESX) and high efficiency solution heat exchanger on COP for a double-effect series-flow absorption chiller. A simulation program has been prepared for the cycle analysis of absorption chillers. As a result, Solution heat exchangers(LSX, HSX) are a most effective element for the COP than the others. In spite of the poor contribution to COP, SCA make a rule to reduce the crystallization phenomena of LiBr solution at solution heat exchanger. And the optimum solution split ratio are varied with the relative size of RSX and LSX.

  • PDF

lmplementation of Bellboy Robot using LiDAR (라이더를 이용한 벨보이 로봇의 구현)

  • Park, Cha-Hun;Park, Seong-Sik;Jo, Seong-Gik;Kim, Young-Chan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.01a
    • /
    • pp.231-232
    • /
    • 2018
  • 최근 항공 산업 발전으로 여행객들의 수가 증가하고 있으며, 호텔 이용객 수도 더불어 증가하는 추세이다. 호텔 이용객의 증가로 시설 이용 시 서비스 지연과 혼잡 그리고 서비스 품질 저하 등이 발생하게 되면서 호텔 이용객들의 시설 이용 만족도가 하락하게 되고 또한 호텔 근무 직원들의 업무 피로도가 높아지고 누적되면서 직업 만족도가 떨어지는 연쇄적인 문제점들이 발생하고 있다. 본 연구는 호텔에 방문하는 이용객들에게 캐리어 운반과 객실 안내 및 호출 서비스 등 각종 서비스 업무를 직원 대신 수행하게 되면서 현 문제점들을 어느 정도 경감시키고 이에 따라 고객 만족도 및 호텔 직원들의 업무 만족도를 증가시킬 수 있을 것으로 사료된다.

  • PDF

The Study on High Efficiency Cycle Characteristics of the Absorption Chiller (흡수식 냉동기 고효율화를 위한 사이클 설계)

  • Park, Chan-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.662-668
    • /
    • 2008
  • The objectives of the present work are to investigate the influence of the solution cooled absorber(SCA), refrigerant drain heat exchanger(RSX), exhaust gas/solution heat exchanger(ESX) and high efficiency solution heat exchanger on COP for a double-effect series-flow absorption chiller. A simulation program has been prepared for the cycle analysis of absorption chillers. As a result, solution heat exchangers(LSX, HSX) are the most effective element for the COP than the others. In spite of the poor contribution to COP, SCA plays an important role to reduce the crystallization phenomena of LiBr solution at solution heat exchanger. And the optimum solution split ratio varies with the relative size of RSX and LSX.