• Title/Summary/Keyword: Left breast

Search Result 193, Processing Time 0.027 seconds

The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.

A Study on the Pulse Wave Parameter in Post Mastectomy Women (유방암 절제술 여성의 맥파요인 연구)

  • Kim, Gyeong-Cheol;Park, Sang-Wook;Kim, Yi-Soon;Kim, Yun-Hee
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.101-112
    • /
    • 2011
  • Objectives : This study was done to investigate the degree of the pulse wave parameter of post-mastectomy women and to identify the relationships between each of them. Methods : Data were obtained from public health center in Busan Metropolitan city. Participants were 82 post-mastectomy women aged 31-82. the data collection was from Oct, 1, 2010 to Oct, 31, 2010. the data were analyzed with descriptive statistics, one-way ANOVA, Duncan test. A p-value less than .05 was considered significant by 2-tailed test. All statistical analyses were performed with SPSS/Win(ver 12.0). Results : As for the difference in the pulse wave by the general characteristics. The pulse energy was showed highly in the order of Chon, Quan and Chuk of left and right pulse respectively. In the pulse energy of left Quan and right Chon, the case of both mastectomy was showed highly and in the pulse energy of left Chuk, the case of right mastectomy was showed highly. Left and right pulse energy of menopause female were significantly higher than normal range except left Chon and Chuk. In h1, h2, h4, h5, t1, t2, AP and Aw, the pulse energy of left Chon was showed the largest significantly. In As, the pulse energy of right Chon was showed the smallest and in Ad, right Chuk was showed the largest. In RAI, right and left Chuk was showed the highest respectively. Conclusions : From these result, we can see that there are relation between women's age, area of operation breast and menopause after mastectomy in pulse wave. The result of this study will become basic data necessary for the Oriental Medicine treatment to reduce or prevent women's functional difficulties, symptomatology after mastectomy.

A Case Report of Cyclophosphamide plus Doxorubicin-induced Side effects in Patient with Both Sides Breast Cancer Treated with Integrative Medicine Therapy Including Pharmacopuncture. (유방암 환자의 cyclophosphamide, doxorubicin 유발 부작용에 대한 약침을 포함한 통합 암 치료 1례)

  • Kim, Minserh;Jung, Yu-jin;Hong, Sang-hoon
    • Journal of Korean Traditional Oncology
    • /
    • v.23 no.1
    • /
    • pp.33-43
    • /
    • 2018
  • Objectives: To observe the mitigating effects of a Traditional Korean Medicine(TKM) treatment program especially including pharmacopuncture, with Cyclophosphamide and doxorubicin chemotherapy on a both sides breast cancer patient. Methods: AA 74 year-old female patient diagnosed with both sides breast cancer (Right) pT1bpN0M0, (Left) pT1cpN1Mx was admitted to hospital of Dong-eui university in May of 2017. She received Cyclophosphamide and Doxorubicin from May $31^{st}$ to August $2^{nd}$, 2017 followed by TKM treatment consisting of herbal medicine, acupuncture, moxibustion and pharmacopuncture (Trionycis Carapax, Non-toxic Bee Venom, and Cultivated Wild Ginseng Extract) for a period of almost 4 months, from May $13^{th}$ to August $19^{th}$, 2017. Symptoms were evaluated by the grade of chief complaints refer to Common Terminology Criteria for Adverse Events (CTCAE) and Eastern Cooperative Oncology Group (ECOG). Results: TKM including pharmacopuncture alleviated chemotherapy-induced nausea, fatigue, joint pain, diarrhea, insomnia. Conclusions: This case study potentiates TKM with pharmacopuncture's significant efficacy in aiding breast cancer patients suffering from Cyclophosphamide plus Doxorubicin induced adverse effects. Further research should take place for clear understanding of the exact amount of dosage and safety. Moreover it must be accompanied by long-term follow up researches.

A Case Report of Metastatic Breast Cancer Patient Treated with Integrative Cancer Treatment (전이성 유방암 환자의 통합 암 치료에 대한 증례보고)

  • Ha, Su-jeong;Lee, Sung-cheol;Park, So-jung;Jeon, Hyung-joon;Lee, Yeon-Weol;Cho, Chong-kwan;Yoo, Hwa-seung
    • Journal of Korean Traditional Oncology
    • /
    • v.24 no.1
    • /
    • pp.19-28
    • /
    • 2019
  • Objective : The purpose of this study is to report and observe effects of Integrative Cancer Treatment (ICT) on metastatic breast cancer patient. Method : A left breast cancer patient diagnosed with recurrence on liver and bones April 2018. The patient had received paclitaxel chemotherapy for two months and discontinued it because of tumor progression and side effects. The patient has been treated with ICT since March 2018 and has been taking capecitabine since October 2018. The clinical outcomes were measured by computed tomography, laboratory findings including tumor markers (CEA, CA15-3). The clinical outcomes were measured by computed tomography, laboratory findings including tumor markers (CEA, CA15-3), liver function test (AST, ALT), Eastern Cooperative Oncology Group performance status (ECOG PS), and numeric rating scales (NRS). Results : After the ICT, tumor size was partially decreased accompanying by reducing the levels of tumor markers. Major clinical symptoms induced by paclitaxel chemotherapy were improved. There were no severe adverse events induced by ICT based on National Cancer Institute Common Terminology Criteria for Adverse Events (NCI CTCAE) version 5.0. Conclusion : This case suggests that ICT may have synergistic effect for the treatment of metastatic breast cancer patient in conjunction with capecitabine.

Treatment of Gynecomatia in a Patient with Prader-Willi Syndrome (Prader-Willi Syndrome 환자에서 여성형 유방의 치험례)

  • Kang, Nak Heon;Song, Seung Han;Oh, Sang Ha
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.656-658
    • /
    • 2007
  • Purpose: Prader-Willi Syndrome(PWS) is a congenital chromosomal disorder characterized by compulsive and early development of obesity. Obesity is identified as the main cause of morbidity in PWS individuals. Also, body change for rapid weight gain, such as gynecomastia, can cause considerable functional and psychological trauma, We corrected successfully gynecomastia in PWS patient, so we reported our experience of surgical method and literature reviews. Methods: A 16-year-old male patient presented with gynecomastia. He was diagnosed as with PWS at pediatric department. We performed reduction mammaplasty using inferior pedicle and Wise pattern. Excision amount was 1350g in right breast and 1415g in left breast. Also, we managed upper and lateral fullness of breast with liposuction. Results: There were no specific complications, such as hematoma, infection, nipple-areola complex necrosis, and so on. Also, aesthetic and functional outcome was acceptable Conclusion: We experienced successful correction of gynecomastia in PWS patient, and found advantages of conventional reduction mammaplasty using inferior pedicle and Wise pattern at this specific situation.

Anomaly of Deep Inferior Epigastric Vessels detected at the Elevation of Rectus Abdominis Musculocutaneous Flap: A Case Report (횡복직근피부피판거상시 발견된 깊은아래배벽 혈관의 이상: 증례보고)

  • Han, Kyu Nam;Chang, Hak
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.480-482
    • /
    • 2008
  • Purpose: Unexpected vascular anomaly can make the surgeon embarrassing and even affects on the operative results of free flap reconstruction. We experienced one case of abnormal course of deep inferior epigastric vessels during the elevation of rectus abdominis musculocutaneous free flap for breast reconstruction. Methods: A 38-year-old female patient who had modified radical mastectomy on her left breast underwent delayed breast reconstruction with rectus abdominis musculocutaneous free flap. Results: Flap elevation was performed in the traditional manner. During the flap elevation, it was detected that the deep inferior epigastric vessels ran between the rectus abdominis muscle and anterior rectus sheath along the midline after traversing the rectus muscle. The reconstructive surgery was successful and there were no postoperative complications. Conclusion: This is the first case reported in Korea. We should always know about the possibilities of unexpected anomaly that we can encounter.

Differential imaging diagnosis of a swelling after extraction in a breast cancer patient with radiotherapy and chemotherapy (방사선치료와 화학요법을 받은 유방암 환자에서 발생한 발치 후 종창의 진단영상학적 감별 진단)

  • Huh Kyung-Hoe;An Byung-Mo;Kim Mi-Ja;Park Kwan-Soo;Heo Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.36 no.3
    • /
    • pp.163-168
    • /
    • 2006
  • A 60-year-old female, who complained of delayed healing and swelling after extraction of left lower second molar during chemotherapy, visited our department. She had a history of a resection surgery of breast cancer and postoperative radiotherapy. The conventional radiographs showed diffuse permeative bone destruction in posterior mandibular body, which gave the first radiologic impression of osteonecrosis associated with radiotherapy or chemotherapy. And bone metastasis from the breast cancer was also considered in the differential diagnosis. On the enhanced computed tomography (ECT) the posterior mandibular body was occupied by a large expansile lesion showing central low attenuation with peripheral rim enhancement. Magnetic resonance images revealed that the low attenuated area on ECT did not show as high signal intensity as water on T2 weighted image and indicated solid component of a tumor. The final diagnosis was central squamous cell carcinoma. We present the diagnostic imaging features of the patient with special emphasis on the differential diagnosis.

  • PDF

The Shoulder Pain due to Metastatic Breast Cancer -A Case Report-

  • Kim, Sae-Young;Jung, Min-Woo;Kim, Jin-Mo
    • The Korean Journal of Pain
    • /
    • v.24 no.2
    • /
    • pp.119-122
    • /
    • 2011
  • A rotator cuff tear causes shoulder pain and limits movement of the shoulder joint. A chronic degenerative change or impingement is the reason for a rotator cuff tear. Diagnosis is made based on medical history and, physical and radiological examinations. Other causes of shoulder pain include calcific tendinitis, degenerative arthropathy, joint dislocation, fracture, and primary or metastatic neoplasm. However, metastatic cancer in the shoulder joint is difficult to diagnosis. We experienced a case in which a 46-year-old female patient complained of left shoulder pain and limited joint mobility, and these symptoms were due to metastatic breast cancer in the shoulder.

Effects of Breast Dose on Plain Abdominal Position (복부 방사선검사 자세가 유방선량에 미치는 영향)

  • Joo, Young-Cheol;Kim, Sheung-Hyuk
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.155-159
    • /
    • 2020
  • The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 kVp, 320 mA, 50 ms, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μGy and 414.46±33.52 μGy for erect AP, and 145.80±18.52 μGy and 148.76±12.92 μGy in erect PA. The superficial breast dose was 754.00±68.36 μGy on the medial side and 674.06±45.58 μGy on the lateral side in the erect AP, 70.66±7.98 μGy on the medial side, and 86.46±15.35 μGy on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.

Usefulness of the Mammography and the Breast Ultrasound (유방의 X선 검사와 초음파 검사의 유용성 연구)

  • Lee, In-Ja;Park, Kye-Yeon
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.349-356
    • /
    • 2007
  • Conclusions below are drawn after survey date from 1,969 samplers of mammography and 1,531 breast ultrasound for 10 months, from 1 July 2006 to 30 April 2007. 1. Ages between 40 and 50 of samplers take the largest part of age distribution, and 68.57% of mammography and 71.32% of samplers are fallen under the category. 2. Samplers judged by diseased patients are 31.95% samplers of mammography and 45.79% samplers of breast ultrasound. 3. Age distributions of diseased patients were from 30 to 60 in mammography, 30 to 50 in breast ultrasound. 4. Breast ultrasound shows little difference between left side and right side of diseased part, but mammography shows significant diseased part in both sides. 5. As a result of reading examination, there is higher probability of detection in order of Calcification, Nodular, Mass in mammography. And Cyst, Nodular, Mass in breast ultrasound. 6. As a reading examinations, probability of judging a certain disease in high in mammography, but breast ultrasound shows 1 or 2 kinds of disease.

  • PDF