The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy  

Kim, Jong Wook (Department of Radiation Oncology, Seoul National University Hospital)
Woo, Heon (Department of Radiation Oncology, Seoul National University Hospital)
Jeong, Hyeon Hak (Department of Radiation Oncology, Seoul National University Hospital)
Kim, Kyeong Ah (Department of Radiation Oncology, Seoul National University Hospital)
Kim, Chan Yong (Department of Radiation Oncology, Seoul National University Hospital)
Yoo, Suk Hyun (Department of Radiation Oncology, Seoul National University Hospital)
Publication Information
The Journal of Korean Society for Radiation Therapy / v.26, no.2, 2014 , pp. 329-336 More about this Journal
Abstract
Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.
Keywords
인공 유방 확대술;반대측 유방;피폭 선량;차폐 효율;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Jemal A, Bray F, Center MM, Ferlay J, Ward E, Forman D: Global cancer statistics. CA Cancer J Clin 2011;61:69-90   DOI
2 송병주, 손병호 외 : 2006-208 유방암 백서 Breast cancer facts & figures. 한국유방암학회 2008;5-7
3 Yerko OB, Mohammad S, Marsha D. MN, et al : Multileaf field-in-field forward-planned intensitymodulated dose compensation for whole-breast irradiation is associated with reduced contralateral breast dose: A phantom model comparison. Radiothe Oncol 2007;82:324-328   DOI   ScienceOn
4 Chang SX, Deschesne KM, cullip TJ, et al : A comparison of different intensity modulation treatment techniques for tangential breast irradiation. Int J Radiat Oncol Biol Phys 1999;45:1305-1314   DOI   ScienceOn
5 Vicini FA, Sharpe M, Kestin L, et al : Optimizing breast cancer treatment efficacy with intensity-modulated tangential beam irradiation of the intact breast. Int J Radiat Oncol Biol Phys 1999;44:1155-1164   DOI   ScienceOn
6 박효원, 강구정, 정기용 등 : 유방암 환자의 생존율. 대한 외과학회지 1996;50:322-329
7 Xu XG, Bednarz B, Paganetti H: A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction. Phys Med Biol 2008;53:193-241   DOI   ScienceOn