• Title/Summary/Keyword: Leakage risk

Search Result 424, Processing Time 0.03 seconds

A Plan to Ensure Safety of Electrical Installation in Empty Houses by Measuring Zero Phase Current (영상전류 측정을 이용한 부재수용가의 전기설비에 대한 안전확보 방안)

  • Lim, Young-Bae;Bae, Seok-Myung;Kim, Young-Seok;Park, Chee-Huyn;Kim, Gi-Hyun;Cho, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.196-201
    • /
    • 2006
  • A electrical fault that may generate an electrical disaster is defined as any abnormal condition caused by reduction in the insulation strength. To find out the abnormal condition, periodical inspections have being performed every 3 years. Recently, the number of empty houses during normal working hours is rising by dramatic increase in the number of nuclear families and double income families. To define the potential risk of the electric installation, measurement of zero phase current has been being considered. But the measured value could not be adapted to an absolute reference to the installation because the measured zero phase current value also contained capacitive leakage current. Therefore, in this paper, the correlation between the condition of the electrical installation and the zero phase current was analyzed. The result focuses on to detect them in a cost efficient way.

Quantitative Safety Assessment for Hydrogen Station (수소 충전소에 대한 정량적 안전성 평가)

  • Seong, D.H.;Rhie, K.W.;Kim, T.H.;Oh, D.S.;Oh, Y.D.;Seo, D.H.;Kim, Y.G.;Kim, E.J.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.111-116
    • /
    • 2012
  • This study is about the quantitative safety assessment of hydrogen station in Korea operating with on-site type. This was written by background information that before qualitative safety assessment to write. For the qualitative safety assessment method, the study used FMEA(failure mode & effect analysis) and HAZOP(hazard & operability), and adopted the FTA(fault tree analysis) as the quantitative safety assessment method. To write the FTA, we wrote FT by Top event that hydrogen leakage can be called most serious accident of hydrogen station. Each base event collect reliability data by reliability data handbook, THERP-HRA and estimation of the engineering. Assessment looked at the high frequency and the possible risk through Gate, Importance, m.cutsets analysis.

A Study on Improving Management of Substances Requiring Preparation for Accidents Facilities (사고대비물질 취급시설 관리방안 연구)

  • Kim, S.B.;Park, C.H.;Cho, M.S.;Lee, J.S.;Kim, J.M.;Noh, H.R.;Seok, G.S.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.77-82
    • /
    • 2012
  • The leakage of toxic chemicals impact seriously on human being and environment, therefore during their treatment process, a proper management system is necessary to control their toxic effect. This study was designed to suggest the management regulation that supports business managers and facilities management. There are no extra regulation to control emergency accidents and terrors in chemical facilities. Developed countries like USA operate the management standards to control the toxic chemical and facilities according to their toxicity and processes. In order to solve this problem, we have analysed the advanced nations standard methods of security in chemical plants to study the new security management regulation which helps to prevent the chemical accidents. Especially, in USA, CCPS (Center for Chemical Process Safety), SVA (Security Vulnerability Assessment) and RBPSs (Risk-Based Performance Standards) of DHS (Department of Homeland Security) were invest I gated. On the basis of the results, we have suggested the application methods of the security and safety regulation in Korea.

Invstigation about Sminshing Hacking (Smishing 해킹에 대한 수사기술)

  • Moon, Soon-hol;Park, Dea-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.293-295
    • /
    • 2015
  • This paper proposed have been the business card information to the computer when creating business card printing agency saved to a file, there is always the risk of personal information leakage. Application file organization information into the card, the name, phone number, email address information, such as is capable of easily accessible because it is not encrypted. This paper proposed it encrypts the information entered on the Business Card application file to automate the process of the card application and simplifying the business card application process minimizes the work of staff and linked directly to the print shop how to automatically delete the print file after the completion of business card printing and research.

  • PDF

Cards Automated Designed Research for Personal Information Leak Prevention (개인정보 유출 방지를 위한 명함 자동화 설계 연구)

  • Park, Jong-Youel;Park, Dea-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.275-277
    • /
    • 2015
  • This paper proposed have been the business card information to the computer when creating business card printing agency saved to a file, there is always the risk of personal information leakage. Application file organization information into the card, the name, phone number, email address information, such as is capable of easily accessible because it is not encrypted. This paper proposed it encrypts the information entered on the Business Card application file to automate the process of the card application and simplifying the business card application process minimizes the work of staff and linked directly to the print shop how to automatically delete the print file after the completion of business card printing and research.

  • PDF

Reactivity Considerations with Miscibility of Process Gases in Semiconductor industry (반도체 산업 공정가스의 혼화성에 따른 반응성 고찰)

  • Lee, Keun Won
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.15-24
    • /
    • 2016
  • In the semiconductor industry, the risk of chemical accidents due to miscibility between the many types of chemicals and leakage of toxic chemicals has increased. In order to evaluate the reactivity with miscibility of chemicals, experimental method is the most reliable, but there is a time and cost limitations to be evaluated through experiment all the chemicals. In the study, the reactivity of process gases in the semiconductor industry was considered by the CRW (Chemical Reactivity Worksheets) 3.0 program developed by US NOAA (National Oceanic and Atmospheric Administration) and EPA. The reactivity informations with the miscibility of process gases for semiconductor industry provided, and also a KOSHA guide for the storage/separation of gas cylinders in dispensing cabinets in the semiconductor industry was proposed.

Implementation of Adult Authentication System Using Smartphone and Near-Field Communication (스마트폰과 근거리 무선 통신을 이용한 성인 인증 시스템의 개발)

  • Lee, Chongho;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.617-624
    • /
    • 2015
  • In this paper, an adult authentication system based on authentication certificate was designed and implemented using smartphone and near-field communication. It has three advantages. First, it achieves easy, convenient, and fast authentication by using smartphone and near-field communication. Second, it achieves extremely high security and reliability by exploiting authentication certificate. Third, it achieves extremely low risk of personal information leakage by generating and sending only virtual identification code. Finally, it has a proper legal basis by Digital Signature Act. It consists of adult authentication module, near-field communication control module, policy server module, and database server module. A prototype of the proposed system was designed and implemented, and it was verified to have correct operation.

A Study on the Improvement of Classification of Explosion Hazardous Area using Hypothetic Volume through Release Characteristic (누출특성을 통한 폭발위험장소 선정방법의 개선에 대한 연구)

  • Kim, Dae-Yeon;Chon, Young-Woo;Lee, Ik-Mo;Hwang, Yong-Woo
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.2
    • /
    • pp.31-39
    • /
    • 2017
  • Classify of explosion hazardous areas must be made at the site where flammable materials are used. This reason is that it is necessary to manage ignition sources in of explosion hazardous areas in order to reduce the risk of explosion. If such an explosion hazard area is widened, it becomes difficult to increase the number of ignition sources to be managed. The method using the virtual volume currently used is much wider than the result using CFD(Computational Fluid Dynamics). Therefore, we tried to improve the current method to compare with the new method using leakage characteristics. The result is a realistic explosion hazard if the light gas is calibrated to the mass and the heavy gas is calibrated to the lower explosion limit. However, it is considered that the safety factors should be taken into account in the calculated correction formula because such a problem should be considered as a buffer for safety.

A Study on Integrated Safety Management System of LNG Storage/Transport Facilities (LNG 저장/수송 시설의 통합 안전 관리 시스템 개발에 관한 연구)

  • Lee, Sang-Ho;Lim, Young-Sub;Han, Chong-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.1-6
    • /
    • 2008
  • The safety management of the LNG industry which shows huge growth recently, become an essential element. So the necessity of development for the pre-existing LNG storage/transport facility has been shown up and the improvement of information technology (IT) of these days make it possible to synthesize several models for integrated LNG facilitiy safety management system. This system will contains risk analysis/assessment technology, explosion, leakage and diffusion model construction technology, real-time monitoring and fault diagnosis technology, and reliability progression technology of process information through data reconciliation. The final integrated safety management system will contribute the increase of LNG industry's safety and exportation of technique.

  • PDF

A study on Priority Control Target(high-risk) Selection for Monitoring of Internal Data Leakage Prevention (내부정보유출방지 모니터링을 위한 중점관리 대상(고위험군) 선정에 관한 연구)

  • Park, Jang-Su;Kim, Su-Hyun;Lee, Im-Yeong
    • Annual Conference of KIPS
    • /
    • 2014.11a
    • /
    • pp.492-494
    • /
    • 2014
  • 정보유출사고가 증가됨에 따라, 기업 및 기관 내 주요정보(개인정보 및 핵심기술)가 유출되어 큰 피해가 발생하고 있다. 이러한 정보유출 사고 중 대부분이 내부자에 의한 고의 또는 실수로 발생하는 경우가 대부분이다. 이를 방지하기 위해 다양한 보안 솔루션을 도입하여 운영하고 있지만 내부자에 의한 정보유출사고는 본인이 소유하고 있는 권한을 이용하여 불법적인 정보유출을 시도하는 것으로, 이러한 위험행동을 탐지하는 것은 쉽지 않다. 이를 해결하기 위해 기업 및 기관에서는 기 구축된 다양한 보안 솔루션을 통합하여 모니터링 할 수 있는 '내부정보유출방지 모니터링시스템'을 구축하고 있으며, 내부정보유출방지 모니터링을 위한 연구도 지속적으로 진행되고 있다. 따라서 본 논문에서는 중점관리 대상(고위험군) 선정을 통해 효율적인 내부정보유출방지 모니터링을 수행할 수 있도록 연구하고자 한다.