• Title/Summary/Keyword: Leakage Correction

Search Result 61, Processing Time 0.066 seconds

Dual-Output Single-Stage Bridgeless SEPIC with Power Factor Correction

  • Shen, Chih-Lung;Yang, Shih-Hsueh
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.309-318
    • /
    • 2015
  • This study proposes a dual-output single-stage bridgeless single-ended primary-inductor converter (DOSSBS) that can completely remove the front-end full-bridge alternating current-direct current rectifier to accomplish power factor correction for universal line input. Without the need for bridge diodes, the proposed converter has the advantages of low component count and simple structure, and can thus significantly reduce power loss. DOSSBS has two uncommon output ports to provide different voltage levels to loads, instead of using two separate power factor correctors or multi-stage configurations in a single stage. Therefore, this proposed converter is cost-effective and compact. A magnetically coupled inductor is introduced in DOSSBS to replace two separate inductors to decrease volume and cost. Energy stored in the leakage inductance of the coupled inductor can be completely recycled. In each line cycle, the two active switches in DOSSBS are operated in either high-frequency pulse-width modulation pattern or low-frequency rectifying mode for switching loss reduction. A prototype for dealing with an $85-265V_{rms}$ universal line is designed, analyzed, and built. Practical measurements demonstrate the feasibility and functionality of the proposed converter.

Single Power-conversion AC-DC Converter with High Power Factor (고역률을 갖는 단일 전력변환 AC-DC 컨버터)

  • Cho, Yong-Won;Park, Chun-Yoon;Kwon, Bong-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • This paper proposes a single power-conversion ac-dc converter with a dc-link capacitor-less and high power factor. The proposed converter is derived by integrating a full-bridge diode rectifier and a series-resonant active-clamp dc-dc converter. To obtain a high power factor without a power factor correction circuit, this paper proposes a suitable control algorithm for the proposed converter. The proposed converter provides single power-conversion by using the proposed control algorithm for both power factor correction and output control. Also, the active-clamp circuit clamps the surge voltage of switches and recycles the energy stored in the leakage inductance of the transformer. Moreover, it provides zero-voltage turn-on switching of the switches. Also, a series-resonant circuit of the output-voltage doubler removes the reverse-recovery problem of the output diodes. The proposed converter provides maximum power factor of 0.995 and maximum efficiency of 95.1% at the full-load. The operation principle of the converter is analyzed and verified. Experimental results for a 400W ac-dc converter at a constant switching frequency of 50kHz are obtained to show the performance of the proposed converter.

Interrupted Single-layer Suture Technique in Esophageal Anastomosis Using Monofilament Polypropylene Suture (Monofilament Polypropylene사를 이용한 단속단층 식도문합술)

  • 성시찬;편승환
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.711-717
    • /
    • 1998
  • Background: Although various anastomotic techniques and suture materials have been used in esophageal anastomosis, anastomotic leakage and stenosis are still somewhat frequent and serious complications when compared to other intestinal anastomoses. We have used interrupted single-layer suture technique using monofilament polypropylene suture in various esophageal anastomoses, including repair of the esophageal atresia, since 1990. Methods and method: We retrospectively evaluated the efficacy of this technique on postoperative leakage and stenosis in several esophageal reconstructions. The esophageal reconstructions using this technique were performed in 90 patients at Dong-A University Hospital from April 1990 through December 1996. Results: Anastomotic leakage occurred in 5 patients(5.6%) with one operative death. Stenosis at the anastomotic site occurred in 15 patients(n=86, 17.4%), which was most common in esophagogastrostomy(22%) and least common in esophagocolostomy (5%). This result was comparable to other methods including the autosuture technique. Conclusions: We concluded that this suture technique in esophageal anastomosis can be used with reasonable results in various esophageal reconstructions including correction of the esophageal atresia.

  • PDF

Power Factor with Single Power Stage AC/DC Converter Operated in Active-Clamp Mode (능동 클램프 모드로 동작하는 단일 전력 AC/DC 컨버터에 의한 역률개선)

  • Yoon, Shin-Yong;Baek, Hyun-Soo;Kim, Yong;Kim, Cherl-Jin;Eo, Chang-Jin
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.392-401
    • /
    • 2001
  • This paper presents the single-stage high power factor AC to DC converter operated in active-clamp mode. The proposed converter is added active-clamping circuit to boost-flyback single-stage power factor corrected power supply. The active-clamping circuit limits voltage spikes, recycles the energy trapped in the leakage inductance, and provides a mechanism for achieving soft switching of the electronic switches to reduce the switching loss. The auxiliary switch of active-clamping circuit uses the same control and driver circuit as the main switch to reduce the additional cost and size. To verify the performance of the proposed converter, a 100W converter has been designed. The proposed converter gives good power factor correction, low line current harmonic distortions, and tight output voltage regulation, as used unity power factor.

  • PDF

Isolated PFC Converter Based on an ADAB Structure with Harmonic Modulation for EV Chargers

  • Choi, Seung-Won;Kim, Yoon-Jae;Lee, Il-Oun;Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.383-394
    • /
    • 2018
  • This paper presents an isolated power factor correction converter for general-purpose electric vehicle chargers with a wide output voltage range. The converter is based on an asymmetrical dual active bridge structure so that the voltage stress of switching devices can be eliminated by transferring the transformer leakage inductance to the circuit parameters. Harmonic and output controls are performed by secondary switches, and primary switches are only operated at a fixed frequency with a 50% duty ratio. A harmonic modulation technique is also adopted to obtain a near-unity power factor without input current monitoring. The feasibility of the proposed charger is verified with a 3.3 kW prototype.

Considerations on the use of a Boost PFC Regulator Used in Household Air-conditioning Systems (over 3kW)

  • Jang Ki-Young;Suh Bum-Seok;Kim Tae-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.589-592
    • /
    • 2002
  • The CCM (Continuous Conduction Mode) boost topology is generally used in the PFC (Power Factor Correction) regulator of household air-conditioning systems. There are three kinds of power devices-bridge rectifier diodes, FRDs (Fast Recovery Diodes), and IGBTs (or MOSFETs) - used In a boost PFC regulator. Selecting the appropriate device is very cumbersome work, specially, in the case of FRDs and IGBTs, because there are several considerations as described below: 1) High frequency leakage current regulation (conducted and radiated EMI regulation) 2) Power losses and thermal design 3) Device cost. It should be noted that there are trade-offs between the power loss characteristic of 2) and the other characteristics of 1) and 3). This paper presents a detailed evaluation by using several types of power devices, which can be unintentionally used, to show that optimal selection can be achieved. Based on the given thermal resistances, thermal analysis and design procedures are also described from a practical viewpoint.

  • PDF

A Single Stage Isolated Power Factor Correction Power Supplies using Clamping Circuit (클램핑 회로를 이용한 단계층 절연 역률 보정 전원 공급장치)

  • Seo, Jai-Ho;Lee, Hee-Seung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2021-2023
    • /
    • 1998
  • In this paper we further propose to add a very simple regenerative clamping circuit to SSIPP to reduce the voltage stress and to recycle the energy trapped in the leakage inductance of the isolation transformer, thus eliminating the need for a lossy snubber circuit. In addition, this proposed clamping circuit also provides a mechanism to reset the magnetizing current of the output transformer of SSIPP employing a Forward converter as the output stage. Simulations and experimental results are reported to verify the operation and performance of the SSIPP with regenerative clamping.

  • PDF

A study on the Correction of Leakage Reactances of AC servo motor (교류 서보 전동기의 누설 리액턴스 보정에 관한 연구)

  • Lim, Jeong-Pil;Chun, Jang-Sung;Jung, Hyun-Kyo;Yoon, Joong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.215-217
    • /
    • 1997
  • 본 논문에서는 유한요소 해석을 통한 리액턴스 보정 방법을 제안한다. 동기 리액턴스는 대상 전동기의 유한요소 해석을 통하여 자계 분포를 계산하여 구할 수 있고 엔드 누설 리액턴스는 3차원 유한요소 해석의 결과로부터 계산하여 보정한다. 제안된 보정 과정을 추가한 자기 등가회로법으로 교류 서보 전동기를 해석한 결과와 실험치를 비교하여 본 논문의 해석 방법의 타당성을 확인한다. 이러한 연구를 통해서 교류 서보 전동기 뿐 아니라 일반 전동기를 해석함에 있어서 리액턴스를 보다 정확히 고려할 수 있고 고정밀의 전동기를 설계하는 데에도 유용하게 사용될 수 있을 것이다.

  • PDF

Clinical Results of Surgical Treatment of an Isolated Complete Atrioventricular Septal Defect (완전방실중격결손증의 외과적 요법에 관한 임상적 고찰)

  • 이정상
    • Journal of Chest Surgery
    • /
    • v.24 no.2
    • /
    • pp.123-134
    • /
    • 1991
  • Twenty eight patients had undergone repair of an isolated complete atrioventricular septal defect between April 1986 and September 1990 in Seoul National University Children`s Hospital. The group comprised 13 male and 15 female patients. They ranged in age from 2 months to 8 years[mean 18.6months] and in weight from 3. 4kg to 23kg[mean 9.0$\pm$4.6kg]. They were analysed as Rastelli type A in 17 patients, Rastelli type B in 2 patients, and Rastelli type C in 9 patients. Seven patients had concomitant Down`s syndrome. All patients had large left-to-right shunt[mean pulmonary to systemic flow ratio 3.5 $\pm$2.2 ranging from 0.68 to 10.0] and high pulmonary systolic pressure[mean 74$\pm$18.8mmHg, ranging from 35 to 110]. In 11 patients, one patch technique was used to close the atrial and ventricular septal defect and 16 patients were undergone by two patch technique. We urgently managed only one patient by pulmonary artery banding whose anatomy was Rastelli type C and severe mitral regurgitation was identified. Postoperative complete A - V block was noted in 3 patients, two of whom were dead in operating room due to combined LVOTO and myocardial failure, and one patient with Rastelli type C was undergone by VVI type permanent pacemaker insertion 1wk later after two patch technique, but we had to manage him by modified Konno operation and total correction due to LVOTO and VSD leakage and severe mitral regurgitation 3 years later. Another two reoperation cases due to severe mitral regurgitation after two patch technique were undergone, one of whom we managed by mitral annuloplasty 3 months later but aggravated mitral regurgitation made us to control him by MVR 3 months later. Another one case of VSD leakage and tricuspid regurgitation was managed by total correction but she died of respiratory insufficiency 14 days later. We experienced pulmonary hypertensive crisis in 3 patients, who were dead in two cases comparing with one control case. So operative mortality is 9/27[33.6%], in one patch group of 3/11[29.2%] comparing with two patch group of 6/16[37.5%]. In summary, causes of death were pump weaning failure, myocardial failure and low cardiac output syndrome and pulmonary hypertensive crisis, resp. failure, complete AV block. Mean follow up period is 15.8$\pm$10.7 months[ranging from 3months to 37 months]

  • PDF

Early Onset Subsequent Vertebral Compression Fracture after Percutaneous Verteroplasty (경피적 척추 성형술 후 조기에 발생한 새로운 척추 압박골절)

  • Kim, Jong-Kil;Choi, Byeong-Yeol;Park, Young-Chul;Kim, Dong-Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.24-29
    • /
    • 2019
  • Purpose: To evaluate the characteristics and the risk factors of early onset subsequent vertebral compression fractures after percutaneous vertebroplasty. Materials and Methods: A total of 44 patients, who had a new subsequent vertebral fracture after percutaneous vertebroplasty for an osteoporotic vertebral compression fracture between January 2013 and December 2015, were recruited. The patients were divided into two groups according to the onset period of subsequent fracture. The number of patients who had a fracture within 3 months following vertebroplasty were 22 cases (Group A); after 3 months were 22 cases (Group B). Variables, including age, sex, bone mineral density (BMD), body mass index (BMI), preexisting vertebral compression fracture, location of the initial fracture, intradiscal cement leakage, injected cement volume, restoration of vertebral body height, and correction of kyphosis, in the two groups were analyzed and compared retrospectively. Results: The age, sex, BMD, BMI, preexisting vertebral compression fracture, location of the initial fracture, intradiscal cement leakage, and correction of kyphosis were similar in the two groups. Both a greater volume of bone cement injected and a greater degree of vertebral height restoration contributed significantly to the risk of fracture within 3 months. Conclusion: The cement volume and degree of height restoration are risk factors for early onset fracture at the adjacent vertebrae after percutaneous vertebroplasty and close attention is needed during the follow-up period.