• Title/Summary/Keyword: Leak Monitoring System

Search Result 65, Processing Time 0.036 seconds

The Development of Real-Time Leak Monitoring System for Management of Hazardous Material Pipeline (유해물질 이송관로 파손누출 실시간 예방 및 감시 기술개발)

  • Chae, Sookwon;Seo, Jaesoon;Kim, Joonseok
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.2
    • /
    • pp.122-129
    • /
    • 2016
  • In this study, a dual structured pipe for a preventive monitoring on a accident damage, a smartphone app program for a survey and a construction data collection and a server program for a real-time monitoring were developed. A pilot system was installed in the test field to analyze effects of a system developed in this study. The data for a damage prevention was detected by the attached sensors on the pipe. Exclusion was tested by the pressure sensors to be installed at regular intervals. The app and server programs was enabled to the real-time data collection and real-time monitoring linked by VRS survey equipments and a smartphone.

Companies Entering the Metabus Industry - Major Big Data Protection with Remote-based Hard Disk Memory Analysis Audit (AUDIT) System

  • Kang, Yoo seok;Kim, Soo dong;Seok, Hyeonseon;Lee, Jae cheol;Kwon, Tae young;Bae, Sang hyun;Yoon, Seong do;Jeong, Hyung won
    • Journal of Integrative Natural Science
    • /
    • v.14 no.4
    • /
    • pp.189-196
    • /
    • 2021
  • Recently, as a countermeasure for cyber breach attacks and confidential leak incidents on PC hard disk memory storage data of the metaverse industry, it is required when reviewing and developing a remote-based regular/real-time monitoring and analysis security system. The reason for this is that more than 90% of information security leaks occur on edge-end PCs, and tangible and intangible damage, such as an average of 1.20 billion won per metaverse industrial security secret leak (the most important facts and numerical statistics related to 2018 security, 10.2018. the same time as responding to the root of the occurrence of IT WORLD on the 16th, as it becomes the target of malicious code attacks that occur in areas such as the network system web due to interworking integration when building IT infrastructure, Deep-Access-based regular/real-time remote. The concept of memory analysis and audit system is key.

Implementation of RTD-2000 Based Waterworks Pipe Network Monitoring System using Internet Map Service (범용지도를 이용한 RTD-2000 기반의 상수도 관망 모니터링 시스템의 구현)

  • Park, Jun-Tae;Hong, In-Sik
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.11
    • /
    • pp.1450-1457
    • /
    • 2011
  • Currently most of leak detection monitoring systems use digital maps with paying royalties, and this increases the cost of system construction and financial burdens on local self-governing bodies that manage such systems. Moreover, they have inefficiencies in repair and maintenance, functional expansion, and compatibility with other systems. Thus, this study developed a waterworks pipe network monitoring system that pursues low cost and high efficiency using general-purpose maps on the Internet such as google maps. As this system uses highly compatible free maps, it costs less in construction and its hardware requirements are lower than existing systems, and consequently, overall monitoring performance is enhanced and the cost of construction goes down sharply. This study also proposed a method for pipeline DB construction, which can be started together with the construction of the monitoring system, in order to improve the field applicability of the system.

Integrated Monitoring System using Log Data (로그 데이터를 이용한 통합모니터링 시스템)

  • Jeon, Byung-Jin;Yoon, Deok-Byeong;Shin, Seung-Soo
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • In this paper, we propose to implement an integrated monitoring system using log data to reduce the load of analysis task of information security officer and to detect information leak in advance. To do this, we developed a transmission module between different model DBMS that transmits large amount of log data generated by the individual security system (MSSQL) to the integrated monitoring system (ORACLE), and the transmitted log data is digitized by individual and individual and researches about the continuous inspection and measures against malicious users when the information leakage symptom is detected by using the numerical data.

Building of Monitoring System for Real-time Leak Detection of Water Distribution (실시간 누수탐지 모니터링 시스템의 구현)

  • 정대권;홍인식
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2004.05a
    • /
    • pp.810-813
    • /
    • 2004
  • 한해 누수로 인하여 많은 양의 상수가 소실되고 있어 국가 재정낭비를 초래하고 있다. 이는 관의 노후화와 지반침하에 의한 파이프의 파손 둥 여러 요인에 의해 발생하는 것으로 누수를 예측하여 탐지하는 것은 매우 어렵다. 현재 누수를 탐지하는 방법은 여러 가지가 있지만 현실적인 제약과 경험자의 주관적인 판단에 의존하기 때문에 정확한 누수 위치를 찾을 수가 없었다. 본 논문에서는 종래의 누수탐지 방법의 단점을 획기적으로 보완하여 지하에 매설된 상수도 관망을 실시간으로 모니터링 할 수 있는 누수탐지 모니터링 시스템을 제안하였다 또한 제안된 시스템을 GIS상에서 실험함으로서 효율성과 정확성을 입증하였다.

  • PDF

Development of Wireless Communication Based Operation State Monitoring System for Open Rack Vaporizer (무선 통신 기반 해수식 기화기 운영 상태 모니터링 시스템 개발)

  • Yoo, Seung-Yeol;Joen, Ming-Sung;Lee, Jae-Chul;Kang, Dong-Hoon;Kim, Dong-Goen;Lee, Soon-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.5
    • /
    • pp.280-287
    • /
    • 2022
  • An open rack vaporizer is a facility that vaporizes liquefied natural gas using sea water. When a vaporization efficiency of the open rack vaporizer decreases, liquefied natural gas can leak, which can cause great damage to the facility. Operators have to monitor the operation state of the facility in real-time to prevent the accident. However, operators have visited the site and have checked the state by looking at the value of sensors installed in the open rack vaporizer through indicators. For the safe operation of the open rack vaporizer, a monitoring system is needed to monitor the operation state of the open rack vaporizer in real-time without the need for operators to visit the site. In this paper, we developed a long term evolution based monitoring system to monitor the operation state of the open rack vaporizer. The developed system can monitor the real-time operation state of the open rack vaporizer at a control center far from the facility. For the system development, data transmission infrastructure using long term evolution was built. Afterwards a software was developed to monitor the operation state of the open rack vaporizer in real-time using the transmitted data. Finally, performance evaluation was conducted to confirm that the developed system operated successfully without data transmission delay or data missing.

Safety Monitoring Sensor for Underground Subsidence Risk Assessment Surrounding Water Pipeline (상수도관로의 주변 지반침하 위험도 평가를 위한 안전감시 센서)

  • Kwak, Pill-Jae;Park, Sang-Hyuk;Choi, Chang-Ho;Lee, Hyun-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.306-310
    • /
    • 2015
  • IoT(Internet of Things) based underground risk assessment system surrounding water pipeline enables an advanced monitoring and prediction for unexpected underground hazards such as abrupt road-side subsidence and urban sinkholes due to a leak in water pipeline. For the development of successful assessment technology, the PSU(Water Pipeline Safety Unit) which detects the leakage and movement of water pipes. Then, the IoT-based underground risk assessment system surrounding water pipeline will be proposed. The system consists of early detection tools for underground events and correspondence services, by analyzing leakage and movement data collected from PSU. These methods must be continuous and reliable, and cover certain block area ranging a few kilometers, for properly applying to regional water supply changes.

Development of Gas Leak Detecting System Based on Quantum Technology (양자기술기반 가스 누출 감지 시스템 개발)

  • Kwon, Oh Sung;Park, Min Young;Ban, Changwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.57-62
    • /
    • 2021
  • Gas is an energy source widely used in general households and industrial sites, and is also a process material widely used in petrochemical and semiconductor processes. However, while it is easy to use, it can cause large-scale human damage due to leakage, explosion, and human inhalation. Therefore, a gas facility safety management solution that can be safely used at home and industrial sites is essential. In particular, the need to develop advanced gas safety solutions is emerging as gas facilities are aging. In this paper, a technology was developed to measure the presence and concentration of gas leaks from a distance by irradiating photons, the minimum energy unit that can no longer be divided into gas facilities, and analyzing the number of reflected photons. This overcomes technical limitations such as short detection distance and inability to detect fine leaks, which are the limitations of conventional electric/chemical gas sensors or infrared-based gas leak detectors.

Leak Detection and Real-time Monitoring System for Boiler Tube (보일러 튜브 누설 검출 및 실시간 감시 시스템)

  • Choi, Min-Gi;Kim, Jae-Young;Jeong, In-kyu;Kim, Young-Hun;Kim, Yu-Hyun;Kim, Jong-Myon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.07a
    • /
    • pp.67-68
    • /
    • 2018
  • 본 논문에서는 다수의 음향방출 센서로부터 취득한 원 데이터를 관리하고 보일러 튜브에 대한 상태를 실시간으로 진단하고 모니터링을 할 수 있는 네트워크 기반의 보일러 튜브 모니터링 시스템을 제안한다. 본 시스템을 화력발전소 보일러 튜브에 설치한다면 보일러의 불시정지를 예방하는데 효과적일 것으로 기대된다.

  • PDF

Neural Network Approach to Automated Condition Classification of a Check Valve by Acoustic Emission Signals

  • Lee, Min-Rae;Lee, Joon-Hyun;Song, Bong-Min
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.6
    • /
    • pp.509-519
    • /
    • 2007
  • This paper presents new techniques under development for monitoring the health and vibration of the active components in nuclear power plants, The purpose of this study is to develop an automated system for condition classification of a check valve one of the components being used extensively in a safety system of a nuclear power plant. Acoustic emission testing for a check valve under controlled flow loop conditions was performed to detect and evaluate disc movement for valve failure such as wear and leakage due to foreign object interference in a check valve, It is clearly demonstrated that the evaluation of different types of failure types such as disc wear and check valve leakage were successful by systematically analyzing the characteristics of various AE parameters, It is also shown that the leak size can be determined with an artificial neural network.