• 제목/요약/키워드: Lead screw

검색결과 71건 처리시간 0.028초

임플란트 지대주 삭제시의 발생열에 관한 연구 (A Study on the heat generation during implant abutment preparation)

  • 이호진;송광엽;장태엽
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.27-33
    • /
    • 2003
  • Excessive heat generation at the implant-bone interface may cause irreversible bone damage and loss of osseointegration. The effect of heat generation in vitro at the implant surface caused by abutment reduction with high-speed dental turbine was examined. Titanium-alloy abutments connected to a titanium alloy screw-implant embedded in an acrylic-resin block in a $37^{\circ}C$ water bath were prepared. Temperature changes were recorded via embedded thermocouples at the cervix and apex of the implant surface. Analysis of variance for repeated measures was used to compare seven treatment groups. Fifty seconds of continuous cutting with air and water coolant caused a mean temperature increase of $1.24^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $2.50^{\circ}C$ at apex and $1.64^{\circ}C$ at cervix. But, continuous cutting with air coolant caused a mean temperature increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Preparation of implant abutment does not lead to detrimental effect on peri-implant tissues provided that adequate cooling. However, without water cooling, extreme overheating could be provoked, reaching the critical temperature that would lead to irreversible bone damage within only a few seconds.

Synergetics based damage detection of frame structures using piezoceramic patches

  • Hong, Xiaobin;Ruan, Jiaobiao;Liu, Guixiong;Wang, Tao;Li, Youyong;Song, Gangbing
    • Smart Structures and Systems
    • /
    • 제17권2호
    • /
    • pp.167-194
    • /
    • 2016
  • This paper investigates the Synergetics based Damage Detection Method (SDDM) for frame structures by using surface-bonded PZT (Lead Zirconate Titanate) patches. After analyzing the mechanism of pattern recognition from Synergetics, the operating framework with cooperation-competition-update process of SDDM was proposed. First, the dynamic identification equation of structural conditions was established and the adjoint vector (AV) set of original vector (OV) set was obtained by Generalized Inverse Matrix (GIM).Then, the order parameter equation and its evolution process were deduced through the strict mathematics ratiocination. Moreover, in order to complete online structural condition update feature, the iterative update algorithm was presented. Subsequently, the pathway in which SDDM was realized through the modified Synergetic Neural Network (SNN) was introduced and its assessment indices were confirmed. Finally, the experimental platform with a two-story frame structure was set up. The performances of the proposed methodology were tested for damage identifications by loosening various screw nuts group scenarios. The experiments were conducted in different damage degrees, the disturbance environment and the noisy environment, respectively. The results show the feasibility of SDDM using piezoceramic sensors and actuators, and demonstrate a strong ability of anti-disturbance and anti-noise in frame structure applications. This proposed approach can be extended to the similar structures for damage identification.

공진배제를 위한 스템핑 모터의 폐회로제어에 관한 연구 (A Study on Closed-Loop Control of a Stepping Motor for Resonance Elimination)

  • 노상현;김교형
    • 대한기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.90-97
    • /
    • 1991
  • 본 연구에서는 하이브리드 스텝핑 모터의 공진 배제를 위한 폐회로제어시스템 을 개발하였고 펄스 발생, 위치 및 속도변화, 가감속제어, 정여괴전방향결정, 카운트 및 스텝핑 모터의 온/오프기능 등을 하드웨어 대신 마이크로컴퓨터를 이용한 소프트웨 어로 대치하였으며, 구동회로의 복잡함을 피하기 위해 스텝핑 모터의 전용제어기인 PMM8713IC를 사용하였고 궤환정보는 샤프트 엔코더를 사용하였다.그리고 리드 스크 루우를 사용한 1축 테이블을 제작하여 개회로제어시와 폐회로제어시의 동특성 및 공진 현상을 검토하였다.

Crawling 방식을 이용한 관 탐사용 소형 로봇의 이동속도 해석 (Theoretical Velocity Analysis of Micro Robot Based on Crawling Locomotive Mechanism for Pipe Inspection Micro Robot)

  • 장기현;박현준;김병규
    • 대한기계학회논문집A
    • /
    • 제32권8호
    • /
    • pp.633-641
    • /
    • 2008
  • Recently, the necessity for diagnosis and management of pipes has emerged as the issue due to contamination of water supply generated by corrosion of pipes. Although inspection has been performed with industrial endoscopes, the method has limits for full diagnosis of pipes due to the lack of working range. As a solution for this problem, many locomotive mechanisms for a micro robot with endoscope functions were proposed. In this paper, we analyze the locomotive mechanism of crawling robot proposed as locomotive device for pipe inspection. Based on a mechanical modeling of motor and micro robot inside small pipe, the theoretical formula for velocity is obtained. This derived theoretical formula is demonstrated the feasibility through the comparison with experimental result. Also, we could find the most important element influencing the moving velocity of micro robot when the robot operates in small pipe. Consequently, it is expected that this study can supply useful information to design of crawling robot to move in small pipe.

Laser Interferometer를 이용한 초정밀위치결정 피드백시스템의 컴퓨터 시뮬레이션 및 제어성능 평가 (Computer Simulation and Control performance evaluation for Feedback System of Ultra Precision Positioning by using Laser Interferometer)

  • 김재열;김영석;윤성운;곽이구;한재호;유신
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.68-74
    • /
    • 2001
  • This system is composed of fine and coarse apparatus, measurement system and control system. Piezoelectric actuator is designed for fine positioning. We make a study of precision apparatus that is used in the various industrial machine. The study was carried out to develope a precision positioning apparatus, consisting of servo motor and piezoelectric actuator. Coarse positioning using lead screw is drived by servo motor. Control system output a signal from laser interferometer to amplifier of servo motor and piezoelectric actuator after digital signal processing(DSP). Resolution of this apparatus measure with laser interferometer. In this study, design method and control system with ultra precision position apparatus are researched. As the first step, we have estimated for control performance and system stability before an actual apparatus is manufactured by MATLAB with SIMULINK including various functions those are composed of pre-design and system modeling.

  • PDF

이족보행로봇의 설계와 동적보행을 위한 모의실험 (Design and Dynamic Walking Simulation of a Biped Robot)

  • 박인규;염영일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.87-90
    • /
    • 2001
  • This paper presents a design of new type biped robot and dynamic walking simulation for this system. The robot is distinguished from other one by which has a parallel mechanism type trunk and lead-screw type actuators to drive the joints of the trunk, knee and ankle. The basic consideration on the design is that it is able to accommodate itself to human's daily environments without any other modification of around and also to operate its upper limbs more smoothly with a spine functional trunk. It is designed according to a human with about 130 cm height and about 30 kg weight. And it also is able to dynamically walk on an even ground. It has constructed with total 14 DOFs which have two legs, a hip, and a trunk. The joints of each leg and trunk are adopted with a parallel structure which has good kinematic characteristics and take light weight. To test of the capacity of joint actuators and to analysis of the dynamic properties of the biped robot, optimized trunk trajectory is determined by means of an approximated FFT method based on ZMP criteria, and dynamic simulation is performed using DADS with a 1.1 time/step velocity on the even ground during four steps.

  • PDF

Laser Interferometer를 이용한 초정밀위치결정 피드백시스템의 컴퓨터 시뮬레이션 및 제어성능 평가 (Computer Simulation and Control Performance Evaluation for Feedback System of Ultra Positioning by using Laser Interferometer)

  • 김재열;이규태;곽이구;한재호;김창현
    • 한국공작기계학회논문집
    • /
    • 제11권1호
    • /
    • pp.17-25
    • /
    • 2002
  • This system is composed of fine and coarse apparatus, measurement system and control system. Piezoelectric actuator is designed far fee positioning. We make a study of precision apparatus that is used in the various industrial machine. The study was carried out to develope a precision positioning apparatus, consisting of servo motor and piezoelectric actuator Coarse positioning using lead screw is thrived by servo motor. Control system output a signal from laser interferometer to amplifier of servo motor and piezoelectric actuator after digital signal processing (DSP). Resolution of this apparatus measure with laser interferometer. In this study, design method and control system with ultra precision position apparatus are researched. As the first step, we have estimated for control performance and system stability before an actual apparatus is manufactured by MATLAB with SIMUUNK including various frictions those are composed of pre-design and system modeling.

족근 관절 경비 인대 결합 손상 (Ankle Syndesmotic Injury)

  • 곽희철;권용욱
    • 대한족부족관절학회지
    • /
    • 제15권4호
    • /
    • pp.187-194
    • /
    • 2011
  • Ankle injuries may involve the distal tibiofibular syndesmosis and can be associated with a variable degree of trauma to the soft tissue and osseous structures that play an important role in ankle joint stability. Ankle syndesmotic injury may occur solely as a soft tissue injury or in association with variable ankle fractures. Ankle syndesmotic injury does not necessarily lead to ankle instability; however, the coexistence of deltoid ligament injury critically destabilizes the ankle joint. The prevalence of these injuries may be higher than previously reported. The diagnosis of syndesmotic injury as not always easy because isolated ankle sprains may be missed in the absence of a frank diastasis and syndesmotic instability may be unnoticed in the presence of bimalleolar ankle fractures. Controversies arise at almost every phase of treatment includings : type of fixation(screw size, type of implant), number of cortices required for fixation and of need for hardware removal. Regardless of controversies, the most important goal should be restore and maintain the normal tibiofibular relationship to allow for healing of the ligamentous structures of the syndesmosis.

마이크로 구동 요소부품의 PECVD를 이용한 플라즈마 질화 공정의 기계적특성 연구

  • 이상민;김강삼;안경준;이지환
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.301-301
    • /
    • 2013
  • 구동형 부품(Actuated component)중의 하나인 LeadScrew는 이송장치를 구성하는 핵심 부품으로 소재로는 탄소강, 합금강, 스테인레스강 등이 주로 이용된다. 다양한 IT기기의 정밀 이송 및 고속 구동에 사용되며, 제품의 성능을 결정하는 중요 핵심 부품으로 사용되고 있다. IT기기용 구동 요소 부품은 정밀 가공성의 제약으로 내식성이 우수한 스테인레스강 소재보다는 일반적으로 소재비가 저렴하고 가공성이 우수한 탄소강 소재를 사용하게 되며, 위 소재를 사용하면 대기중의 수분등에 의한 부식환경에서 쉽게 부식되어 부식방지를 위한 표면처리 기술개발이 필요하다.또한, 구동형 부품은 부품 상호간의 심한 마찰 등과 같은 가혹한 조건에 노출되어, 부품의 내마모성 및 표면 경도등을 향상시켜 부품의 수명을 연장하고자 한다. 그러기 위해 선 표면경도, 내마모성, 내식성 등의 다양한 기능이 요구되며, 성능을 만족시키기 위해서 열표면처리 공정을 확인하고자 한다.본 연구에서는 냉간압조용 강선인 SWCH계열 표면에 PECVD 장치로 플라즈마 질화공정을 이용하여 동일조건(압력, Gas flow, Power)하에서 $500{\sim}550^{\circ}C$의 온도 범위 내에서 30~300 min의 시간 조건으로 실험을 진행하였다. 위 시험편으로 XRD를 통해 각 플라즈마 질화 공정 조건에 따른 상 변화를 확인하였고, 염수분무테스트를 통해 내식성을 확인하였다. 표면경도 및 단면경도를 통한 실용질화층을 확인하고, 마모테스트를 통하여 마찰계수를 확인하여 표면경도, 내마모성, 내식성을 충족하는 공정에 대한 실험을 진행하였다.

  • PDF

A Dual-mode Pico-positioning System using Active Aerostatic Coupling

  • Mizumoto, Hiroshi;Yabuta, Yoshito;Arii, Shiro;Yabuya, Makoto;Tazoe, Yoichi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권2호
    • /
    • pp.32-37
    • /
    • 2007
  • This paper proposes a dual-mode ultra precision positioning system for machine tools and measuring machines. The objective was to position a machine table with a picometer order of resolution, i.e., pico-positioning. A twist-roller friction drive (TFD) was used in coarse-mode positioning. The TFD, which was driven by an AC servomotor, is a kind of lead screw in mechanical terms, and several centimeters of machine table movement was controlled with a nanometer order of positioning resolution. To eliminate lateral vibration caused by the TFD, an active aerostatic coupling driven by piezoelectric actuators was inserted between the TFD and the machine table. This active aerostatic coupling was also applied as a feed drive device for fine-mode positioning; in the fine mode, the positioning resolution was 50 pm. Factors influencing pico-positioning, such as how noise from displacement sensors and vibrations in the aerostatic guideway affect positioning resolution, are discussed.