• Title/Summary/Keyword: Lead extraction

Search Result 258, Processing Time 0.025 seconds

Equivalent Circuit Model Parameter Extraction for Packaged Bipolar Transistors (패키지된 바이폴라 트랜지스터의 등가회로 모델 파라미터 추출)

  • Lee Seonghearn
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.12
    • /
    • pp.21-26
    • /
    • 2004
  • In this paper, a direct method is developed to extact RF equivalent circuit of a packaged BJT without optimization. First, parasitic components of plastic package are removed from measured S-parameters using open and short package patterns. Using package do-embedded S-parameters, a direct and simple method is proposed to extract bonding wire inductance and chip pad capacitance between package lead and chip pad. The small-signal model parameters of internal BJT are next determined by Z and Y-parameter formula derived from RF equivalent circuit. The modeled S-parameters of packaged BJT agree well with measured ones, verifying the accuracy of this new extraction method.

Characterization of Heavy Metal-enriched Particles from Contaminated Soils in a Military Shooting Range (군사격장 오염토양 내 고농도 중금속함유 입자의 기초특성연구)

  • Kim, Jeeeun;Kim, Jeongjin;Bae, Bumhan;Kim, Younghun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.11
    • /
    • pp.25-31
    • /
    • 2013
  • Civil and military firing ranges are usually contaminated with heavy metals such as lead and copper and remediation is required. Acid washing and extraction are common remediation methods. Lead contaminated firing range soil samples were collected and a preliminary study was conducted to evaluate the characteristics of the contamination and the contribution of high specific gravity particles. Ethylenediamine tetra acetic acid(EDTA) extraction was applied for the removal of heavy metal but the extraction was not feasible for the firing range soil. Even after the repeated EDTA extraction, the contamination were still over the Korean environmental standard indicating that soil particles highly contaminated with heavy metal which release the heavy metal ion even after the repeated extraction. Some colored and higher specific gravity particles were separated from the soil samples and analyzed. The colored particles have specific gravity of 2.5-6.6. The saturation ratio of Pb and EDTA was 4.9-32%. After removal of these colored particles, the sandy soil showed moderate contamination which can be treated with soil washing. This was proved with the five-level sequential extraction and TCLP tests.

A Study of Heavy Metal-Contaminated Soil Remediation with a EDTA and Boric acid Composite(I): Pb (EDTA와 붕산 혼합용출제를 이용한 중금속으로 오염된 토양의 처리에 관한 연구(I): 납)

  • Lee Jong-Yeol;Kim Yong-Soo;Kwon Young-Ho;Kong Sung-Ho;Park Shin-Young;Lee Chang-Hwan;Sung Hae-Ryun
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.1-7
    • /
    • 2004
  • To choose a organic acid and in-organic acid composite which is the most effective in soil-flushing process cleaning lead-contaminated sites, lead removal rates were investigated in the experiments with some organic acids; 0.01M of EDTA showed the highest lead-extraction rate ($69.4\%$) compared to the other organic acids. Furthermore, the lead removal rates were measured with 0.01M of EDIA and 0.1M of in-organic acid ; a EDTA and boric acid composite showed the highest lead-extraction rate ($68.8\%$) at pH5 compared to the other composites. As the concentration of boric acid was increased from 0.1M to 0.4M in a 0.01M of EDTA and boric acid composite, lead removal rate was decreased from $68\%\;to\;45\%$. But as the concentration of EDTA was increased from 0.01M to 0.04M in a EDTA and 0.1M of boric acid composite, permeability was decreased from $6.98{\times}10^{-4}cm/sec$ (0.01M of EDTA) to $5.99{\times}10^{-4}cm/sec$ (0.04M of EDTA). However, permeability was increased from $4.41{\times}10^{-4}cm/sec$ (0.03M of EDTA) to $6.26{\times}10^{-4}cm/sec$ (0.03M of EDTA and 0.1M of boric acid composite). indicating EDTA could increase lead dissolution/extraction rate and decrease permeability. In this system, lead remediation rate is the function of lead dissolution rate from soils and permeability of the composite into soils, and the optimized [EDTA]/[Boric acid] ratio is [0.01M]/[0.1M].

Applications of carbon-based materials in solid phase micro-extraction: a review

  • Guo, Jian;Park, Soo-Jin;Meng, Long-Yue;Jin, Xinghua
    • Carbon letters
    • /
    • v.24
    • /
    • pp.10-17
    • /
    • 2017
  • With continuous development in the field of sample preparation technology, solid phase micro-extraction (SPME) has been widely used in analytical chemistry for high extraction efficiency and convenient operation. Different materials lead to different extraction results. Among existing materials, carbon-based materials are still attracting attention from scientists due to their excellent physical and chemical properties as well as their modifiable surfaces, which could enhance the adsorption effects of SPME fiber. This review introduces the preparation methods and applications of different kinds of carbon-based material coatings on fibers. In addition, directions for future research on carbon material composites are discussed.

Local anesthesia for mandibular third molar extraction

  • Kim, Chang;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.5
    • /
    • pp.287-294
    • /
    • 2018
  • Mandibular third molar extraction is commonly performed in dental clinics. However, the optimal method of anesthesia has not been established for this procedure. The conventional inferior alveolar nerve block is the most widely used method. However, its success rate is not high and it may lead to complications, such as aspiration and nerve injury. Therefore, various anesthesia methods are being investigated. Articaine has been proven to be efficacious in a number of studies and is being used with increasing frequency in clinical practice. In this review article, we will briefly review various local anesthesia techniques, anesthetics, and a computer-controlled local anesthetic delivery (CCLAD) system, which reduces pain by controlling the speed of drug injection, for mandibular third molar extraction.

불포화 자연토의 포화도에 따른 동전기 정화특성에 관한 실험적 연구

  • 김병일;김익현;김기년;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.302-305
    • /
    • 2003
  • The electrokinetic remediation tests for natural soil contaminated by lead are performed on unsaturated conditions, in which the degree of saturation is controlled through the changes in water content and the constant unit weight. At the degree of saturation of 70% the small acid range and electrical potential is developed. The changes in the water content are little above the saturation of 90%. But it is increased by 1.7 times at the degree of saturation of 70%. Finally, the efficiency of extraction is improved at 70% than 100%.

  • PDF

Determination of Lead in Different Samples by Atomic Absorption Spectrometry after Preconcentration with Dithizone Immobilized on Surfactant-Coated Alumina

  • Dadfarnia, S.;Haji Shabani, A.M.;Dehgan Shirie, H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.4
    • /
    • pp.545-549
    • /
    • 2002
  • A simple and rapid technique for the separation and preconcentration of lead in water and biological samples has been devised. Preconcentrationis based on the depositionof analyte onto a column packed with dithizone immobilized on sodium dodecyl sulfate coated alumina at pH $\geq$ 3. The trapped lead is eluted with 5 mL of 4 M nitric acid and determined by flame atomic absorption spectroscopy. A sample of 1 L, results in a preconcentration factor of 200 and the precision at 20${\mu}g$ $L^{-1}$ is 1.3%(n=8). The procedure is applied to tap water, well water, river water, vegetable extract and milk samples, and accuracy is assessed through recovery experiments and by independent analysis by furnace atomic absorption.

Desorption Kinetics and Removal Characteristics of Pb-Contaminated Soil by the Soil Washing Method: Mixing Ratios and Particle Sizes

  • Lee, Yun-Hee;Oa, Seong-Wook
    • Environmental Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.145-150
    • /
    • 2012
  • Pb-contaminated soil at a clay shooting range was analyzed by the sequential extraction method to identify metal binding properties in terms of detrital and non-detrital forms of the soil. Most of the metals in the soils existed as non-detrital forms, exchangeable and carbonate-bound forms, which could be easily released from the soil by a washing method. Therefore, the characteristics of Pb desorption for remediation of the Pb-contaminated soil were evaluated using hydrochloric acid (HCl) by a washing method. Batch experiments were performed to identify the factors influencing extraction efficiency. The effects of the solid to liquid (S/L) ratio (1:2, 1:3, and 1:4), soil particle size, and extraction time on the removal capacity of Pb by HCl were evaluated. Soil samples were collected from two different areas: a slope area (SA) and a land area (LA) at the field. As results, the optimal conditions at 2.8 to 0.075 mm of particle size were 1:3 of the S/L ratio and 10 min of extraction time for SA, and 1:4 of the S/L ratio and 5 min of extraction time for LA. The characteristics of Pb desorption were adequately described by two-reaction kinetic models.

Real Time ECG Derived Respiratory Extraction from Heart Rate for Single Lead ECG Measurement using Conductive Textile Electrode (전도성 직물을 이용한 단일 리드 심전도 측정 및 실시간 심전도 유도 호흡 추출 방법에 관한 연구)

  • Yi, Kye-Hyoung;Park, Sung-Bin;Yoon, Hyoung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.335-343
    • /
    • 2006
  • We have designed the system that measure one channel ECG by two electrode and extract real-time EDR with more related resipiration and comportable to subject by using conductive textile. On the assumption that relation between RL electrode and potential measurement electrode is coupled with RC connected model, we designed RL drive output to feedback two electrode for reduction of common mode signal. The conductive textile which was used for two ECG electrode was offered more comfort during night sleep in bed than any other method using attachments. In the method of single-lead EDR, R wave point or QRS interval area could be used for EDR estimation in traditional method, it is, so to speak, the amplitude modulation(AM) method for EDR. Alternatively, R-R interval could be used for frequency modulation(FM) method based on Respiratory Sinus Arrhythmia(RSA). For evaluation of performance on AM EDR and FM EDR from 14 subject, ECG lead III was measured. Each EDR was compared with both temperature around nose(direct measurement of respiration) and respiration signal from thoracic belt(indirect measurement of respiration) on mean squared error(MSE), cross correlation(Xcorr), and Coherence. The upsampling interpolation technique of multirate signal processing is applied to interpolating data instead of cubic spline interpolation. As a result, we showed the real-time EDR extraction processing to be implemented at micro-controller.