A simple and rapid technique for the separation and preconcentration of lead in water and biological samples has been devised. Preconcentrationis based on the depositionof analyte onto a column packed with dithizone immobilized on sodium dodecyl sulfate coated alumina at pH $\geq$ 3. The trapped lead is eluted with 5 mL of 4 M nitric acid and determined by flame atomic absorption spectroscopy. A sample of 1 L, results in a preconcentration factor of 200 and the precision at 20${\mu}g$ $L^{-1}$ is 1.3%(n=8). The procedure is applied to tap water, well water, river water, vegetable extract and milk samples, and accuracy is assessed through recovery experiments and by independent analysis by furnace atomic absorption.
Keywords
Lead; Solid phase extraction; AAS.;
Citations & Related Records

Times Cited By Web Of Science : 22  (Related Records In Web of Science)
Times Cited By SCOPUS : 23
연도 인용수 순위
1 Uzawa, A.; Narukawa, T.; Okutani, T. Anal. Sci. 1998, 14, 395.   DOI   ScienceOn
2 De Mora, S. J.; Harrison, R. M. Anal. Chem. Acta 1983, 153, 307.   DOI   ScienceOn
3 Chisholm, J. J. Scientific American 1971, 224, 15.
4 Trrner, D. Chem. Br. 1980, 16, 312.
5 The Biochemistry of Lead in the Environmental; Nriagu, J. O.,Ed.; Elsevier: Amsterdam, 1978.
6 Brajter, K.; Miazek, I.; Fresenius, Z. Anal. Chem. 1983, 315, 121.   DOI
7 Analytical Quality Control (Harmonised Monitoring) Committee,Analyst 1985, 110, 1.   DOI
8 Sandell, E. B. Colorimetric Determination of Trace of Metals;Interscience: New York, 1956; p 84.
9 Valfredo, A. L.; Sergio, L. C. F. Anal. Chem. Acta 2001, 441, 281.   DOI   ScienceOn
10 Manzoori, J. L.; Sorouraddin, M. H.; Haji Shabani, A. M.Microchem. J. 1999, 63, 295.   DOI   ScienceOn
11 Hiraide, M.; Ohta,Y.; Kawaguchi, H.; Fresenius, J. Anal. Chem.1994, 46, 123.
12 Hiraide, M.; Iwasawa, J.; Hiramatsu, S.; Kawaguchi, H. Anal. Sci.1995, 11, 611.   DOI   ScienceOn
13 Manzoori, J. L.; Sorouraddin, M. H.; Haji Shabani, A. M. J. Anal.At. Spectrom. 1998, 13, 305.   DOI   ScienceOn
14 Valsaraj, K. T. Sep. Sci. Technol. 1992, 27, 1633.
15 Dadfarnia, S.; Jafarzadeh, M. H. Microchem. J. 1999, 63, 226.   DOI   ScienceOn
16 Dadfarnia, S.; McLeod, C. W. Appl. Spec. 1994, 48, 133.
17 Genaro, M. C.; Balocchi, C.; Campi, E.; Mentasti, E.; Argua, R.Anal. Chem. Acta 1983, 151, 339.   DOI   ScienceOn
18 Dojozan, D. j.; Pournaghi-Azar, M. H.; Toutounchi-asr, J. Talanta1998, 46, 123.   DOI   ScienceOn
19 Dadfarnia, S.; Green, I.; McLeod, C. W. Anal. Procc. 1994, 31,61.   DOI
20 Reggers, G.; van Grieken, R.; Fresenius, Z. Anal. Chem. 1984,317, 520.   DOI
21 Lynarn, D. R.; Plantanido, L. G.; Cole, J. F. Environmental Lead;Academic Press: New York, 1975.