• 제목/요약/키워드: Laser Raman Scattering

검색결과 49건 처리시간 0.03초

Design of Hybrid Optical Amplifiers for High Capacity Optical Transmission

  • Kim, Seung-Kwan;Chang, Sun-Hyok;Han, Jin-Soo;Chu, Moo-Jung
    • ETRI Journal
    • /
    • 제24권2호
    • /
    • pp.81-96
    • /
    • 2002
  • This paper describes our design of a hybrid amplifier composed of a distributed Raman amplifier and erbium-doped fiber amplifiers for C- and L-bands. We characterize the distributed Raman amplifier by numerical simulation based on the experimentally measured Raman gain coefficient of an ordinary single mode fiber transmission line. In single channel amplification, the crosstalk caused by double Rayleigh scattering was independent of signal input power and simply given as a function of the Raman gain. The double Rayleigh scattering induced power penalty was less than 0.1 dB after 1000 km if the on-off Raman gain was below 21 dB. For multiple channel amplification, using commercially available pump laser diodes and fiber components, we determined and optimized the conditions of three-wavelength Raman pumping for an amplification bandwidth of 32 nm for C-band and 34 nm for L-band. After analyzing the conventional erbium-doped fiber amplifier analysis in C-band, we estimated the performance of the hybrid amplifier for long haul optical transmission. Compared with erbium-doped fiber amplifiers, the optical signal-to-noise ratio was calculated to be higher by more than 3 dB in the optical link using the designed hybrid amplifier.

  • PDF

분포온도 계측을 위한 광파이버 온도센서 시스템에 관한 연구 (The study on the fiber optic sensor for the distributed temperature measurement)

  • 이광진;최성구;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1746-1749
    • /
    • 1997
  • A distributed optical fiber temperature sensor can continually monitor the measurand at every point along of its fiber length. It is based on OTDR technics which used extreamlly weak backward scattered light called Raman scattering. When the Pulsed high intensity laser light injected into the optical fiber there are several kind of backscattered light such as Rayleigh, Stokes, and anti-Stokes, etc. caused by impurities molecular vibrations. The temperature distribution is derived form the intensity ratio Raman scatted light-Stokes versus anti-Stokes-and the time function between light injection and signal detection. It is shown that the priniciple of distributed sensing, the system desing, and the result of experiments.

  • PDF

레이저 라만 분광법을 이용한 도립형 OMVPE 반응기의 기상 온도 분포 측정 (Gas phase temperature profile measurement of an upflow OMVPE reactor by laser Raman spectroscopy)

  • 박진호
    • 한국결정성장학회지
    • /
    • 제8권3호
    • /
    • pp.448-453
    • /
    • 1998
  • 도립형 OMVPE 반응기를 레이저 라만 분광법을 사용하여 조사하였다. 운반기체인 질소나 수소의 순수한 회전 라만 분산 스펙트럼을 통해 반응기 내부의 축 중심 방향의 온도 분포를 정확히 측정할 수 있었다. 주입 기체의 유속과 반응기의 종횡비가 변수로 변화되었으며 실험결과, 기판 표면 근처의 수직방향 온도 구배를 크게 유지하기 위해서는 보다 빠른 기체 유속의 사용, 보다 큰 반응기 종횡비의 사용, 그리고 질소의 사용이 유리함을 알 수 있었다.

  • PDF

2 파장 라만 산란을 이용한 비침습적 HbA1c 측정 (Non-Invasive HbA1c Measurement Using Two-Wavelength Raman Scattering)

  • 양주란;김형표
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.305-310
    • /
    • 2019
  • The purpose of this study is to classify the concentration of HbA1c (glycosylated hemoglobin), which is an indicator in the management of accurate blood glucose level in diabetic patients, using a non-invasive optical property measurement method. To measure the optical properties of HbA1c, the optical source uses LEDs and laser diodes of 400 nm in the visible region and 1450 nm in the nearinfrared region using thermopile to detect the Raman scattering intensity. An HbA1c control solution was used. As a result, the optical properties of 5% (normal) and 9% (abnormal) HbA1c control solutions showed specificity in which the output values were reversed at 850 nm and 950 nm, respectively. This property was applied to distinguish between normal and abnormal values in diabetes. In addition, considering tissue penetration depths for non-invasive measurements, two wavelengths were determined to be effective in distinguishing the concentrations of HbA1c control solutions at 5%, 7%, and 9%.

Feasibility Study for the Monitoring of Urea in Dialysate Solution using Raman Spectroscopy

  • Kim, Jae-Jin;Hwang, Jin-Young;Kim, Yong-Dan;Chung, Ho-Eil
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.805-808
    • /
    • 2011
  • We have determined the urea concentration in an aqueous solution using Raman spectroscopy by incorporating a Teflon tube as an effective intensity correction standard as well as sample container. A non-overlapping Teflon band was used as the reference peak to correct Raman intensity variations that occasionally resulted from changes in laser power. To increase the sensitivity, we positioned a copper reflector inside the Teflon tube to maximize the collection of Raman scattering. The obtained accuracy using Raman spectroscopy was 0.53 mM, close to the range of accuracy of previous NIR studies (0.15-0.52 mM).

Hot carrier induced carrier transport property on InAs nanowires

  • Kim, Taeok;Park, Sungjin;Kang, Hang-Kyu;Bae, Jungmin;Cho, M.H.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.362.1-362.1
    • /
    • 2016
  • InAs nanowires were synthesized by a vapor-liquid-solid method with InAs powder. The composition and crystalline structure of nanowires were confirmed by energy-dispersive spectroscopy (EDS) and high resolution transmission electron microscopy (HRTEM), respectively. The thermal conduction of nanowires was investigated by the optical method using Raman spectroscopy: i.e., the local temperature on nanowire was determined by laser heating. As temperature increased, the Raman peaks are shifted to low frequency and broadened. The temperature dependent Raman scattering experiments was realized on InAs nanowires with different percentages of zinc-blende and wurtzite structure. The temperature dependence on the nanowire structure has been successfully obtained: the phonon scattering was more increased in InAs heretostructure nanowires, compared to the InAs nanowires with homostructure. The result strongly suggests that the thermal conduction can be effectively controlled by ordered interface without any decrease in electrical conduction.

  • PDF

Selecting Characteristic Raman Wavelengths to Distinguish Liquid Water, Water Vapor, and Ice Water

  • Park, Sun-Ho;Kim, Yong-Gi;Kim, Duk-Hyeon;Cheong, Hai-Du;Choi, Won-Seok;Lee, Ji-In
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.209-214
    • /
    • 2010
  • The Raman shift of water vapor is 3657 $cm^{-1}$, and this Raman signal can be easily separated from other Raman signals or elastic signals. However, it is difficult to make simultaneous Raman measurements on the three phases of water, namely, ice water, liquid water, and water vapor. This is because we must consider the overlap between their Raman spectra. Therefore, very few groups have attempted to make Raman simultaneous measurements even on two elements (water vapor and liquid water, or water vapor and ice water). We have made an effort to find three characteristic Raman wavelengths that correspond to the three phases of water after measuring full Raman spectra of water on particular days that are rainy, snowy or clear. Finally, we have found that the 401-nm, 404-nm, and 408-nm wavelengths are the most characteristic Raman wavelengths that are representative of the water phases when we are using the 355-nm laser wavelength for making measurements.

라만매질 $CH_4$의 전후방 1.54${\mu}m$ 유도라만 산란광의 비대칭적 발생 (Asymmetry of the 1.54${\mu}m$ forward and backward raman gain in methane)

  • 최영수;고해석;강응철
    • 한국광학회지
    • /
    • 제10권2호
    • /
    • pp.89-94
    • /
    • 1999
  • 파장 1.06$\mu\textrm{m}$ Nd:YAG 펌프레이저의 인가에너지와 라만매질 CH4의 압력변화에 따른 전방과 후방 1.54$\mu\textrm{m}$ 유도라만 산란광(stimulated Raman scattering)의 출력 특성을 동시에 측정하여 전후방 유도라만 산란광 발생을 위한 1.06$\mu\textrm{m}$ 인가문턱 에너지, 라만변환의 기울기 효율 및 라만이득계수(Raman gain coefficient)의 측정값과 이론값을 비교 분석하였다. 압력1000 psi에서 후방 기울기 효율은 약 34%이고 전방은 약 18%를 보였다. 라만매질 CH4의 압력이 증가할수록 전방과 후방 라만이득은 비선형적으로 증가할 뿐만아니라, 후방 대 전방 라만이득비도 증가하였다. 압력 1200 psi 이상에서 후방 대 전방 라만이득비는 약 1.4배가 되었고, 압력 1400 psi에서 후방 라만이득계수는 0.32cm/GW이고 전방에서는 0.23cm/GW로 나타났다. 이와 같은 비대칭적 발생은 전방 라만증폭이 펌프광의 국부적 세기와 작용하는 반면 후방은 펌프광의 평균세기와 상호작용하기 때문이다.

  • PDF

라만분광을 이용한 오이 종자의 발아예측 (Germination Prediction of Cucumber (cucumis sativus) Seed using Raman Spectroscopy)

  • 모창연;강석원;이강진;김기영;조병관;임종국;이호선;박종률
    • Journal of Biosystems Engineering
    • /
    • 제37권6호
    • /
    • pp.404-410
    • /
    • 2012
  • Purpose: The objective of this research was to select high quality cucumber (cucumis sativus) seed by classifying into viable or non-viable one using Raman spectroscopy. Method: Both transmission and back-scattering Raman spectra of viable and non-viable seeds in the range from $150cm^{-1}$ to $1890cm^{-1}$ were collected with a laser illumination. Results: The Raman spectra of cucumber seed showed Raman peaks with features of polyunsaturated fatty acids. The partial least squares-discriminant analysis (PLS-DA) to predict viable seeds was developed with measured transmission and backscattering spectra with Raman spectroscopy and germination test results. Various types of spectra pretreatment were investigated to develop the classification models. The results of developed PLS-DA models using the transmission spectra with mean normalization or range normalization, and back-scattering spectra with mean normalization treatment or baseline correction showed 100% discrimination accuracy. Conclusions: These results showed that Raman spectroscopy technologies can be used to select the high quality cucumber seeds.