The purpose of this study is to classify the concentration of HbA1c (glycosylated hemoglobin), which is an indicator in the management of accurate blood glucose level in diabetic patients, using a non-invasive optical property measurement method. To measure the optical properties of HbA1c, the optical source uses LEDs and laser diodes of 400 nm in the visible region and 1450 nm in the nearinfrared region using thermopile to detect the Raman scattering intensity. An HbA1c control solution was used. As a result, the optical properties of 5% (normal) and 9% (abnormal) HbA1c control solutions showed specificity in which the output values were reversed at 850 nm and 950 nm, respectively. This property was applied to distinguish between normal and abnormal values in diabetes. In addition, considering tissue penetration depths for non-invasive measurements, two wavelengths were determined to be effective in distinguishing the concentrations of HbA1c control solutions at 5%, 7%, and 9%.

Keywords

References

  1. World Health Organization (WHO), Global Report on Diabetes, WHO press, Geneva, 2016.
  2. H. Lee, "The role of HbA1C testing in diagnosing diabetes", Korean J. Med., Vol. 79, No. 5, pp. 495-499, 2010.
  3. Commercializations Promotion Agency for R&D Outcomes, "In Vitro Diagnostic Device Market Trend", S&T Mark. Rep., Vol. 40, pp. 1-30, 2016.
  4. K. Lee, S. Lee, H. Paik, S. Lee, "Status of Non-Invasive Biometric Information Processing Technology", PD Issue Rep., Vol. 18-3, No. 4, pp. 84-106, 2018.
  5. W. V. Gonzales, A. T. Mobashsher, and A. Abbosh, "The Progress of Glucose Monitoring-A Review of Invasive to Minimally and Non-Invasive Techniques" Sensors, Vol.19, No. 4, pp. 1-45, 2019. https://doi.org/10.1109/JSEN.2019.2926011
  6. C. Weykamp, "HbA1c: A Review of Analytical and Clinical Aspects". Ann. Lab. Med., Vol. 33, No. 6, pp. 393-40, 2013. https://doi.org/10.3343/alm.2013.33.6.393
  7. J. Sundararajan, V. Palanisamy, and M, Sandeep, "A Novel and Proven System for Non-Invasive Blood Glucose Monitoring using HbA1c", Asian J. Appl. Sci., Vol. 2, No. 3, pp. 253-274, 2009. https://doi.org/10.3923/ajaps.2009.253.274
  8. R. Pandey, S. K. Paidi, T. A. Valdez, C. Zhang, N. Spegazzini, A. R. Dasari, and I. Barman, "Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy", Acc. Chem. Res., Vol. 50, No. 2, pp. 264-272, 2017. https://doi.org/10.1021/acs.accounts.6b00472
  9. T. Pan, M. Li, J. Chen, and H. Xue, "Quantification of glycated hemoglobin indicator HbA1c through near-infrared spectroscopy", J. Innov. Opt. Health Sci., Vol. 7, No. 4, pp. 1350060(1) - 1350060(9), 2014. https://doi.org/10.1142/S1793545813500600
  10. J. Y. Sim, C.-G. Ahn, E.-J. Jeong, and B. K. Kim, "In vivo Microscopic Photoacoustic Spectroscopy for Non-Invasive Glucose Monitoring Invulnerable to Skin Secretion Products", Sci. Rep., Vol. 8, No. 1, pp. 1059(1)-1059(11), 2018. https://doi.org/10.1038/s41598-018-28766-3
  11. https://ko.wikipedia.org/wiki/(retrieved on Aug. 14, 2019).
  12. http://www.labpedia.net/test/82(retrieved on Aug. 14, 2019).
  13. D. M. Nathan, J. Kuenen, R. Borg, H. Zheng, D. Schoenfeld, and R. J. Heine, "Translating the A1C Assay Into Estimated Average Glucose Values", Diabetes Care, Vol. 31, No. 8, pp. 1473-1478, 2008. https://doi.org/10.2337/dc08-0545
  14. E. N. Lazareva, A.Y. Zyubina, I. G. Samuseva, V. A. Slezhkind, V. I. Kochubey, and V. V. Tuchin, "Refraction, fluorescence, and Raman spectroscopy of normal and glycated hemoglobin", SPIE, Vol. 10685, No. 1068540, pp. 1-8, 2018.
  15. S. Lee, "Novel Detection Technology for Glycated Hemoglobin using Gold Nanoparticles", J. Sens. Sci. Technol., Vol. 25, No. 6, pp. 435-439, 2016. https://doi.org/10.5369/JSST.2016.25.6.435
  16. H. Kim, S. Lee, H. Kim, K. Yang, Y. Sohn, "Characteristics of Gold and Silver Bimetallic Surface Plasmon Resonance Chip in Intensity Measurement Mode and Calculation of Refractive Index using Critical Angle", J. Sens. Sci. Technol., Vol. 24, No. 6 pp. 423-428, 2015. https://doi.org/10.5369/JSST.2015.24.6.423
  17. R. GhoshMoulick, J. Bhattachary, S. Roy, S. Basak, and A. Kr. Dasgupta, "Compensatory secondary structure alterations in protein glycation", Biochim. Biophys. Acta., Vol. 1774, No. 2, pp. 233-242, 2007. https://doi.org/10.1016/j.bbapap.2006.11.018
  18. A. I. Erokhin, "Temperature dependence of the refractive index in condensed media", J. Exp. Theor. Phys., Vol. 47, No. 4, pp.669-701, 1978.
  19. http://bmoic.com/technologies.html(retrieved on Aug. 14, 2019).
  20. N. Min, Introduction to Sensor Engineering, Dongilbook, pp. 82-83, 2013.
  21. S. Lee, J. Kim, G. Song, M. Yang, Y. Lee, Application of Analytical Chemistry of Lasers, Kyungnam University Press, pp. 111-121, 1998.