• Title/Summary/Keyword: Lamps

Search Result 1,057, Processing Time 0.04 seconds

Characterization of the Effects of Different Wavelengths of Night-break Lighting on the Fruit Quality and Yield of 'Kyoho' Grapes (파장별 야간 조사에 따른 '거봉' 포도의 품질 및 생산량)

  • Kim, JunHyeok;Park, YoSup;Kwon, YongHee;Jung, MyungHee;Park, Hee-Seung
    • Horticultural Science & Technology
    • /
    • v.35 no.2
    • /
    • pp.170-177
    • /
    • 2017
  • This study was conducted to estimate the light pollution damage caused by night-break lighting in 'Kyoho' grapes. Night irradiation was performed every night for four hours (10 p.m. to 2 a.m.) from the full bloom to the harvest stage using red, blue, and white lamps as artificial light. Fruit yield, soluble solid content, anthocyanin content, and chlorophyll a content were affected by night irradiation. The soluble solid content of the control was $17.5^{\circ}Brix$, approximately $1^{\circ}Brix$ higher than the red ($16.4^{\circ}Brix$), blue ($16.2^{\circ}Brix$), and white light treated grapes ($16.3^{\circ}Brix$). The anthocyanin content of the skin was also higher in the control at $4.08{\mu}g{\cdot}cm^{-2}$ compared to the red ($3.14{\mu}g{\cdot}cm^{-2}$), blue ($2.47{\mu}g{\cdot}cm^{-2}$), and white ($2.82{\mu}g{\cdot}cm^{-2}$) light treated samples. On the other hand, the chlorophyll a content of the control was the lowest at $0.268{\mu}g{\cdot}cm^{-2}$ as compared with the red ($0.339{\mu}g{\cdot}cm^{-2}$), blue ($0.345{\mu}g{\cdot}cm^{-2}$), and white ($0.372{\mu}g{\cdot}cm^{-2}$) light treated samples. Considering that higher soluble solid contents, higher accumulation of anthocyanin, and lower chlorophyll a contents are factors involved in fruit maturation, night irradiation may delay fruit maturation and red light treatment may result in decreased yield. Our results confirmed that night-break lighting regardless of the wavelength provoked light pollution in 'Kyoho' grapes. Therefore, fruit maturation may be poor in the presence of artificial light, including streetlamps, in neighboring vineyards.

Safety education needs among the dental technology-major college students to prevent injuries in their laboratory classes (치기공과 학생들의 실습 중 안전에 대한 안전교육 요구도 특성)

  • Park, Jong-Hee
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.177-198
    • /
    • 2006
  • This study purposed to offer basic data for safety education of the dental laboratory technology after the investigation of how much the students in the dept. of dental laboratory technology are aware of the danger of each instrument, equipment or laboratory procedure that they use during laboratory and how much they demand safety education for this. The objects for this study were 423 students who were in the dept. of dental laboratory technology. In this regard, four colleges which have the dept. of dental laboratory technology were randomly selected to do a questionnaire survey. SPSS 12.0 was used to analyze the collected data. The results were as follows: As for satisfaction with their major, the respondents answered Satisfied (59.1%), Average (35.5%) and Dissatisfied (5.4%). In terms of the production process of a partial denture, they considered casting, polishing the casting body, polishing denture and burn out were most dangerous in order. As for the production process of a full denture, what they regarded as the most dangerous in order was polishing denture, deflasking and wax wash. Regarding the laboratory procedures of porcelain material, casting, trimming casting body, polishing porcelain material and burn out were the most dangerous procedures that they perceived. With regard to materials for use, alcohol, polishing, metal and wire were the most dangerous ones they thought. As for the handling characteristics of each material, small towns showed a higher demand for safety of the handling characteristics of alcohol. In terms of school year and sex, juniors and girls had higher scores in the demand for safety of the handling characteristics of acid. Regarding the handling characteristics of each equipment and instrument, all of small towns, juniors and girls showed the highest demand for safety of the handling characteristics of alcohol lamps. With regard to scores in the demand for safety of other characteristics, all of small towns, juniors and girls had the highest demand for safety of emergency treatment. Concerning the demand for safety education by the completion of safety education, in terms of each material, highest was the demand for safety of acid from the group which completed safety education. In regard to equipments and instruments, when it came to the demand for safety of the handling characteristics of casting machine, the educated group's demand for safety of acid was higher. Regarding other characteristics, the group which was not educated gained higher scores in the demand for safety of emergency treatment. 11. In all areas(materials, machines and others), small towns, girls and juniors showed higher scores in the demand for safety. Based on the above results, it was found that when students conduct the laboratory of dental technology, they would think that many materials, instruments or equipments for use are very dangerous. However, safety education was not fully given to them. Regarding the scores in the damned for safety education, the highest was 4.16 and the lowest was 3.43, which suggests that the scores were generally very high. In this regard, it is necessary to continue delivering a systematic safety education of materials, equipments or instruments used during the laboratory of dental technology. Therefore, through the analysis of each material, instruments or facility used in every laboratory and each process, safety accident types and accident risk factors should be investigated to develop educational materials for this. Moreover, it is required to open safety education as a single course of study or insert safety contents of all materials and machines into the class of dental laboratory instrument or dental materials for the purpose of a systematic and thorough safety education to prevent a safety accident during laboratory.

  • PDF

Effect of Heating by Nano-Carbon Fiber Infrared Lamps on Growth and Vase Life of Cut Roses and Heating Cost (나노탄소섬유 적외선등 난방이 절화장미의 생육과 수명 및 난방비에 미치는 영향)

  • Lim, Mi-Young;Ko, Chung-Ho;Son, Moon-Sook;Lee, Sang-Bok;Kim, Gil-Ju;Kim, Byung-Soo;Kim, Young-Bok;Jeong, Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The greatest and major cost for cut rose production during winter seasons in Korea is cost of heating the greenhouse. A study was conducted on a cost-efficient heating system to reduce expenses of cut rose growers in times of high energy prices. An infrared heating system utilizing radiant energy has an obvious advantage over other heating methods in that the energy is first used to raise temperatures of plants and other objects and subsequently that of the atmosphere, resulting in faster reaching to desired plant temperatures at a reduced heating cost. In this study the heating effect and heating cost saving of a nano-carbon fiber infrared heating system (NCFIHS) installed in cut rose greenhouses in Gimhae, Gyeongnam Province were analyzed comparatively. In addition growth, quality, and vase life of 'Orange Fresh' roses grown in greenhouses heated by NCFIHS against those grown in greenhouses heated by so called an electrical heating system. In greenhouses with a NCFlHS with a set point air temperature of $20^{\circ}C$, plant temperature was maintained at $1{\sim}2^{\circ}C$ higher than the air temperature, and temperatures of growing bed surface and root zone were maintained at $17{\sim}19^{\circ}C$ throughout cold winter nights. The cost for heating in NCFIHS was about 25 and 51% of that of an electrical heating system and a hot water heating system heated by petroleum, respectively. Growth of roses harvested in greenhouses with a NCFIHS was similar to those grown in greenhouses with an electrical heating system. However, cut roses with more intense petal and leaf colors and a longer vase life (fresh weight and amount of water uptake) were harvested in greenhouses with a NCFIHS as compared to those harvested in greenhouses with an electrical heating system.

Studies on the Response to Day-length and Temperature and their Effects on the Yield of Perilla (Perilla ocimoides L.) (들깨의 일장 및 온도에 대한 감응성과 그의 수량에 미치는 영향에 관한 연구)

  • Ik-Sang Yu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.17
    • /
    • pp.79-114
    • /
    • 1974
  • Experiments were conducted to clarify the variations of the ecological characteristics under different day-length and temperature conditions inperilla varieties from 1972 to 1973 in the experimental fields of Crop Experiment Station, O.R.D, Suwon. Thirty-six varieties were tested in the field in 1972 under 6 growing seasons differing seeding dates. from April 5th to June 20th with 15-day interval between each seeding. Pot-experiment also were conducted in 1972 and 1973. The seeds of the 6 varieties tested were sown on May 25th. In this pot-experiment natural condition was regarded as a short-day treatment and 100-W incandescent lamps were used for long-day treatment. Three selected varieties were grown under different. temperature treatments in phytotron in Crop Experiment Station. The results obtained are summarized as follows: 1. Most varieties tested flowered around September 6. The days required to flower were shortened gradually as the planting time was delayed. 2. The varieties used were matured around October 6, but the maturity was shortened when planted early. The days required for maturity after flowering was 26 to 30. 3. The growing period was also shortened gradually when planting time was delayed. 4. Plant height was reduced when planting time was delayed. 5. There were little differences in number of valid branches among planting time I, II and III, while the branch number was reduced as the planting time was delayed. 6. The dry matter weight was gradually increased from planting time I to III, while it was rapidly decreased after planting time IV. 7. It was found that the flowering of perilla was little affected by temperature. The varieties, however, were more sensitive to day-length. 8. No clear tendency was found in the plant height, number of valid branches and dry matter weight by the time and period of day-length and temperature treatments. 9. The highest yield was obtained at planting time III(May 5th) and the yield was decreased at either earlier or later planting. 10. 1, 000 grain weight appeared to be heavier as the planting time was delayed. 11. The number of flower cluster was largest at planting time III (May 5th) and it was decreased as planting time was earlier or later than III. 12. The oil content was also highest at planting time III (May 5th). 13. Days to flowering, days to maturity and total growing period and flowering period did not affect the yield much. 14. The number of valid branches, flower clusters, 1, 000-grain weight and dry matter weight were positively correlated with yield. The relationship between these characters and yield were variable depending upon the planting time.

  • PDF

Effect of $CO_2$ Concentration, NAEH and Light Intensity on the Photoautotrophic Growth of Campanula punctata 'Rubriflora' Plantlets In Vitro (자주초롱꽃의 기내 자가영양배양시 $CO_2$농도, 환기횟수 및 광도가 생장에 미치는 영향)

  • Shim, Jae-Nam;Kim, Gyeong-Hee;Jeong, Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.14 no.4
    • /
    • pp.233-238
    • /
    • 2005
  • Growth of Campanula punctata 'Rubriflora' plantlets, as affected by three levels of photosynthetic photon flux (PPF), 70, 110, and $220{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, two levels of $CO_2$ concentration, 500 and $1,500{\mu}mol{\cdot}m^{-1}$, and two levels of number of air exchanges per hour (NAEH), 0.1 and $2.8 h^{-l}$, was studied. Explants were obtained from photomixotrophically-micropropagated plantlets. Four explants were planted in each $3.7{\times}10^{-4}m^3$ polycarbonate box containing MS basal medium and no added sucrose. Explants were cultured under cool-white fluorescent lamps for $16h{\cdot}d^{-1},\;at\;25\pm1^{\circ}C$ temperature, and $70\~80\%$ relative humidity In treatments of $2.8h^{-1}$ NAEH, a 10mm round hole made on the vessel cap was sealed with a microporous filter. For higher $CO_2$ concentrations in the culture room, $CO_2$ gas was provided from a tank of liquefied $CO_2$. Fresh and dry weights, length of the longest root, and number of leaves significantly increased with increasing PPF and especially $CO_2$ concentration. Length of the longest root, number of leaves, fresh and dry weights, and chlorophyll concentration were enhanced with increased NAEH. However, leaf area was the smallest in the $220{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}\;PPF\;2.8h^{-1}$ NAEH and especially, $1,500{\mu}mol{\cdot}mol^{-1}\;CO_2$ concentration treatment. Treatment effect became more produced with time. Overall, treatment with $220{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}\;PPF\;and\;1,500{\mu}mol{\cdot}mol^{-1}\;CO_2$ gave the most vigorous growth.

Effect of Light Quality during $GA_3$ Imbibition and Germination Temperature on Pepper Seed Germinability (파종 전 $GA_3$와 광질 처리, 발아온도에 따른 고추종자의 발아율)

  • 강진호;심영도;강신윤;조영욱;박아정
    • Korean Journal of Plant Resources
    • /
    • v.12 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • Higher and uniform germination should be necessary because many commercial pepper (Capsicum annum L.) seedlings were nowadays sold to farmer. The experiment was carried out to determine the effect of its cultivars (Daemyung; Wanggochu), GA$_3$ (concentration; period), light quality (red; far-red; blue; dark) during GA$_3$imbibition, and germination temperature (GT: 25 or 15$^{\circ}C$ constant; 25/15$^{\circ}C$ alternating) on the rate of germination done under incandescent lamps until 9 days after sowing. Final seed germination was not different between GA$_3$0 to 1.0 mM concentrations but the elapsed days to 50% germination $(T_{50})$ were more reduced by GA$_3$ treatment than water imbibition. Under $25^{\circ}C$ constant germination temperature, earlier germination was enhanced by GA$_3$treatment showing the lowest rate at darkness, although the final germination rates of water imbibition and GA$_3$ treatments were same. The final germination rates of alternating and 25 $^{\circ}C$ constant GT in cv. Daemyng was also equal, while the germination rates of $25^{\circ}C$ and 15$^{\circ}C$ constant GT were the highest and the lowest regardless of cultivars. There was no difference between light quality treatments impelled during GA$_3$ imbibition when light treated seeds were germinated at alternating and $25^{\circ}C$ constant GT. At 15$^{\circ}C$ constant GT, however, red light or dark treatment during GA$_3$imbibition increased the germination rate since 5 days after sowing.

  • PDF

Effects of Light Sources in Poultry House on Growth Performance, Carcass Yield, Meat Quality and Blood Components of Finishing Broilers (계사 내 광원이 육계 후기의 생산성, 도체수율, 육질 특성 및 혈액성분에 미치는 영향)

  • Hong, Eui-Chul;Kang, Bo-Seok;Kang, Hwan-Ku;Jeon, Jin-Joo;You, Are-Sun;Kim, Hyun-Soo;Son, Jiseon;Kim, Chan-Ho;Kim, Hee-Jin
    • Korean Journal of Poultry Science
    • /
    • v.47 no.3
    • /
    • pp.159-167
    • /
    • 2020
  • This study investigated the effect of different light sources in the poultry house on performance, meat quality, and blood composition of finishing broilers. Two hundred and forty male broilers (1-day-old, 42.2±0.1 g) were divided into three groups and subjected to different light source treatments (incandescent, LED, and fluorescent lamps) from 3 weeks of age (four replications/treatment, 20 birds/replication). After breeding for 6 weeks, the carcass yield and meat quality of broilers with similar body weight (BW; 3.4±0.07 kg) were investigated, and blood components were analyzed. Corn-soybean meal-based feed was provided as starter (CP 22.5%, ME 3,020 kcal/kg), early (CP 18.5%, ME 3,050 kcal/kg), and finishing (CP 18%, ME 3,100 kcal/kg). Performance, carcass yield, meat quality, and blood components were evaluated. BW, BW gain, feed intake, and feed conversion ratio did not show any significant differences among treatments. There was no significant difference on live weight and carcass yield among treatments. There was no significant difference on meat color, shear force, and water holding capacity; however, cooking loss at 17.2% was the highest in the LED treatment (P<0.05). There was no significant difference on blood components except for glucose (blood biochemistry component) among treatments. Glucose was 234.5 mg/dL, 256.9 mg/dL, and 250.1 mg/dL in the three treatments, respectively, with a significant difference between incandescent and LED treatments (P<0.05). These results are used useful as basic data for investigating the effect of lighting in broilers production.

Effect of Different Nutrient Solution and Light Quality on Growth and Glucosinolate Contents of Watercress in Hydroponics (배양액의 종류 및 광질이 물냉이의 생육 및 Glucosinolate 함량에 미치는 영향)

  • Choi, Jae Yun;Kim, Sung Jin;Bok, Kwon Jeong;Lee, Kwang Ya;Park, Jong Seok
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.371-380
    • /
    • 2018
  • Aim of this study was to investigate the effects of different nutrient solutions and various light qualities generated by LED on the growth and glucosinolates contents of watercress (Nasturtium officinale) grown under hydroponics for 3 weeks. The seeds of watercress were sown on crushed rockwool media and raised them for two weeks. They were transplanted in a semi-DFT (deep flow technique) hydroponics system. A controlled-environment room was maintained at $20{\pm}1^{\circ}C$ and $16{\pm}1^{\circ}C$ temperatures and $65{\pm}10%$ and $75{\pm}10%$ relative humidity (day and night, respectively), with a provided photosynthetic photon flux density (PPFD) of $180{\pm}10{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and a photoperiod of 16/8h. To find out the best kinds of nutrient solutions for growing watercress, Otsuka House 1A (OTS), Horticultural Experiment Station in Korea (HES), and Netherland's Proefstaion voor Bloemisterij en Gasgroente (PBG) were adapted with initial EC of $1.0-1.3dS{\cdot}m^{-1}$ and pH of 6.2, irradiating PPFD with fluorescent lamps (Ex-1). Either monochromatic (W10 and R10) or mixed LEDs (R5B1, R3B1, R2B1G1, and W2B1G1) were irradiated with a differing ratio of each LED's PPFD to understanding light quality on the growth and glucosinolates contents of watercress (Ex-2). Although significant difference in the shoot growth of watercress was not found among three nutrient solutions treatments, but the root fresh weight increased by 13.7% and 55.1% in PBG and OTS compared to HES, respectively. OTS increased the gluconasturtiin content by 96% and 65% compared to PBG and HES. Compared with the white light (W10), the red light (R10) showed a 101.3% increase in the shoot length of watercress. Increasing blue light portion positively affected plant growth. The content of total glucosinolates in watercress was increased by 144.5% and 70% per unit dry weight in R3B1 treatment compared with R2B1G1 and W10 treatments, respectively. The growth and total glucosinolates contents of the watercress were highest under R3B1 among six light qualities.

A Study on the Improvement of User Value through the Analysis of the Status of Smart Home Service in Korea Based on the Internet of Things (사물인터넷 기반 국내 스마트 홈서비스 현황 및 사용 후기 분석을 통한 사용자 가치 제고방안에 관한 연구)

  • Yoon, Seong-Jeong;Kim, Min-Yong
    • Management & Information Systems Review
    • /
    • v.36 no.5
    • /
    • pp.45-60
    • /
    • 2017
  • This study aims to elucidate the key improvements through the current state of customer support for smart home services based on the Internet of things and the evaluation of user's usage. Smart home services typically provide a wide range of value in terms of security, safety, manageability (electricity and water use), convenience, and remote management accessibility. In this study, we analyzed the current state of smart home service based on Internet of Samsung, SKT and LG U + companies in Korea. However, since LG U+ is the only company providing user reviews, there is a limit to generalization, but we are trying to figure out whether the customer value is conveyed properly or not, and in which part the customer support is focused to support the service. As a result of analyzing the results of the study, we found that the smart home service is commercialized and marketed in various forms. However, it is questionable whether the technological level and user satisfaction level are sufficiently satisfied. The results of this study are as follows. First, although each company provides usage guidance, they still ask many questions about joining products and using products. Second, there are many defects in the product itself, and it is found that the companies are not satisfied with the overall response. Third, the three companies are focusing on switches, outlets, sensors, and lamps. This is an individual intelligent product rather than an interlocking or linking level, and it can be seen that there are many parts that are not compatible with the concept of the original Internet of things. In conclusion, this study shows that there are still many areas to improve on the level of customer service provision of smart home service, in particular, the ease of use is low and the quality of products is not reliable. We would like to present the improvement of this in detail through this study and reflect the companies that provide it and the service providers.

An Experiment and Analysis for Standardize Measurement on CCFL (냉음극 형광램프의 표준화 계측을 위한 실험과 분석)

  • Jin, Dong-Jun;Jeong, Jong-Mun;Jeong, Hee-Suk;Kim, Jin-Shon;Lee, Min-Kyu;Kim, Jung-Hyun;Koo, Je-Huan;Gwon, Gi-Cheong;Kang, June-Gill;Choi, Eun-Ha;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.331-340
    • /
    • 2008
  • A method of measuring the current and voltage is suggested in the circuit of cold cathode fluorescent lamps (CCFLs) which are driven at a high frequency of $50{\sim}100\;kHz$ and a high voltage of several kV. It is difficult to measure the current and voltage in the lamp circuit, because the impedance of the probe at high voltage side causes the leakage current and the variation of luminance. According to the analysis of equivalence circuit with the probe impedance and leakage current, the proper measuring method is to adjust the input DC voltage and to keep the specific luminance when the probe is installed at a high voltage circuit. The lamp current is detected with a current probe or a high frequency current meter at the ground side and the voltage is measured with a high voltage probe at the high voltage side of lamp. The lamp voltage($V_C$) is measured between the ballast capacitor and the lamp electrode, and the output voltage($V_I$) of inverter is measured between inverter output and ballast capacitor. As the phases of lamp voltage($V_C$) and current ($I_G$) are nearly the same values, the real power of lamp is the product of the lamp voltage($V_C$) by the lamp current($I_G$). The measured value of the phase difference between inverter output voltage($V_I$) and lamp current($I_G$) is appreciably deviated from the calculated value at $cos{\theta}=V_C/V_I$.