• 제목/요약/키워드: Lactate sensor

검색결과 9건 처리시간 0.029초

생물공정 모니터링을 위한 광섬유 포도당 및 젖산 센서의 개발 (Development of Optical Fiber Glucose and Lactate Biosensors for Bioprocess Monitoring)

  • 정창환;손옥재;이종일
    • KSBB Journal
    • /
    • 제32권1호
    • /
    • pp.35-45
    • /
    • 2017
  • In this work the optical fiber glucose and lactate biosensors were developed by using fluorescent dye and enzyme immobilized on the end tip of an optical fiber. 3-Glycidyloxypropyl)methyldiethoxysilane (GPTMS), (3-Aminopropyl) trimethoxysilane (APTMS) and Methyltrimethoxysilane (MTMS) were used to immobilize glucose oxidase (GOD), lactate oxidase (LOD) and ruthenium(II) complex (tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II), $Ru(dpp)_3^{2+}$) as oxygen sensitive fluorescent dye. MTMS sol-gel was an excellent supporting material for the immobilization of $Ru(dpp)_3^{2+}$, GOD, and LOD on the optical fiber. Storage stability of the optical fiber glucose sensor was kept constant over 20 days, while the optical fiber lactate sensor had constant storage stability over 17 days. The optical fiber glucose and lactate biosensors also maintained good operational stability for 20 hours and 14 hours, respectively. The activities of the immobilized enzymes were most excellent at pH 7 and at $25^{\circ}C$. On-line monitoring of glucose and lactate in a simulated process was performed with the optical fiber glucose and lactate biosensors. On-line monitoring results were agreed with those of off-line data measured with high performance liquid chromatography (HPLC).

혈액중 포도당과 젖산의 분석을 위한 광섬유 생물센서 (Fiber-optic biosensor for analysis of glucose and lactate in blood samples)

  • 손옥재;이종일
    • 센서학회지
    • /
    • 제15권1호
    • /
    • pp.28-33
    • /
    • 2006
  • Optical-fiber sensors have been developed to determine the concentrations of glucose and lactic acid in blood samples. Fluorescence dye [tris(2,2'-biphenyridine)-ruthenium(II)-chloride (RuBPY)] was entrapped by using a silicon to the unclad tip of a glass optic fiber. Enzymes like glucose oxidase (GOD) and lactate oxidase (LOD) have been immobilized by acrylamide resin adhesive, adsorption with zeolite or covalent bonding with aminopropyl-triethoxysilan. The fiber-optic glucose/lactate sensor was then used to analyze the concentrations of glucose and lactate in blood samples. The results were compared with the results of HPLC analysis and their difference was in error by less then 5 %.

광섬유 생물센서에 의한 혈액 중 포도당 및 젖산 모니터링

  • 손옥재;김진희;임용식;서국화;정상윤;이종일
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XII)
    • /
    • pp.627-629
    • /
    • 2003
  • In this work fiber-optic biosensor that has been used in medical applications was developed. And we can monitored the concentration of glucose and lactate in blood sample by using developed fiber-optic glucose and lactate sensor. Glucose oxidase(GOD) and Lactate oxidase(LOD) were immobilized by using acrylamide adhesive and zeolite on the tip of the optic fiber.

  • PDF

탄소나노튜브로 개질된 탄소종이 기반 젖산산화효소 - 카탈레이즈 전극 제작 및 특성 분석 (Fabrication and Characterization of Carbon Nanotube-modified Carbon Paper-based Lactate Oxidase-catalase Electrode)

  • 시키;셀바라잔 바르시니;양영일;김혁한;김창준
    • Korean Chemical Engineering Research
    • /
    • 제61권4호
    • /
    • pp.576-583
    • /
    • 2023
  • 본 연구에서는 전극의 전기 전도도 증대와 젖산 산화반응의 부산물인 과산화수소 생성 완화가 젖산 산화효소 전극 성능에 미치는 영향을 조사하였다. 유연성 있는 탄소종이 표면을 단일벽 탄소나노튜브로 개질하여 전극의 전기 전도도를 향상시켰다. 카탈라아제를 도입하여 젖산 산화반응에서 발생하는 과산화수소를 제거하였다. 젖산 산화효소와 카탈라아제가 동시에 고정화된 탄소종이 전극은 젖산 산화효소만 고정화된 탄소종이 전극보다 1.7배 많은 전류를 생성하였다. 단일벽 탄소나노튜브로 개질된 탄소종이 표면에 젖산 산화효소와 카탈라아제가 동시에 고정화된 전극은 171 µA의 전류를 생산하였는데, 이는 탄소종이 표면에 젖산 산화효소만 고정화된 전극이 생산하는 전류보다 2배 높은 값이다. 최적화된 전극은 젖산 농도가 20 mM까지 선형반응을 보여 센서용 전극으로 사용 가능함을 확인하였다.

평면 소자형 락테이트 바이오센서 (Planar microchip-based lactate biosensor)

  • 하정한;허황;강태영;이용석;윤순호;신정원;남학현;차근식
    • 분석과학
    • /
    • 제19권6호
    • /
    • pp.482-489
    • /
    • 2006
  • Pediococcus에서 추출된 lactate oxidase(LOD)를 poly(vinyl alcohol)(PVA)에 고정화하여 2전극계로 구성된 lactate 바이오센서를 제조하였다. Lactate는 LOD 효소와의 반응에서 생성되는 $H_2O_2$를 전기화학적으로 금(Au)위에 형성시킨 Pt-black 층에서 산화시켜 정량 할 수 있었다. Pt-black으로 만들어진 센서는 과산화수소에 대해서 낮은 전위(+300 mV vs. Ag/AgCl)에서 큰 산화전류를 보여주었으며, ascorbic acid, acetaminophen, uric acid 등과 같이 산화되기 쉬운 산화 종들의 영향을 감소시켜주었다. 외부보호막으로는 다양한 종류의 친수성 폴리우레탄을 사용하였다. 센서는 in vitro 방식으로 흐름계와 비흐름계 모두에서 성능을 평가하였다. 제작된 센서는 0.05 M NaCl을 포함하는 0.05 M 인산염 완충용액(pH 7.6)에서 성능을 시험하였으며, 0.1 mM에서 9.0 mM의 lactate 농도구간에서 직선적 감응성을 나타내었다. 최적화된 센서는 $4^{\circ}C$ 완충용액에 보관하였으며, 25일 이상 감응도(sensitivity)가 거의 변화하지 않았다.

A Microbial Fuel Cell Type Lactate Biosensor Using a Metal-Reducing Bacterium, Shewanella putrefaciens

  • KIM, HYUNG JOO;MOON SIK HYUN;IN SEOP CHANG;BYUNG HONG KIM
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권3호
    • /
    • pp.365-367
    • /
    • 1999
  • A fuel cell type biosensor for lactate was developed using a metal-reducing bacterium, Shewanella putrefaciens IR-1. Under the operational conditions, the bacterial cell suspension generated the current without an electrochemical mediator in the presence of lactate. The current was proportional to the lactate concentration up to 30 mM.

  • PDF

Enzyme Sensors Modified with Avidin/Biotin Systembased Protein Multilayers

  • Anzai, Jun-Ichi;Du, Xiao-Yan;Hoshi, Tomonori;Suzuki, Yasuhiro;Takeshita, Hiroki;Osa, Tetsuo
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.591-596
    • /
    • 1995
  • Enzyme multilayers composed of avidin and biotin-labeled enzymes were prepared on the surface of electrode, through a strong affinity between avidin and biotin (binding constant: ca $10^{15} M^{-1}$). The enzyme multilayers were useful for the improvement of the performance characteristies of enzyme sensors. The output current of the enzyme sensors depended linearly on the number of enzyme layers deposited. Thus, lactate oxidase (LOx) and alcohol oxidase (AlOx) were deposited after being modified with biotin for constructing enzyme sensors sensitive to L-lactate and ethanol respectively. It was also possible to deposit two different kinds of enzymes successively in a single multilayer. The glucose oxidase (GOx) and ascorbate oxidase (AsOx) were built into a multilayer structure on a Platinum electrode. The GOx, AsOx multilayer-modified electrode was useful for the elimination of ascorbic acid interference of the glucose sensor.

  • PDF

포도당, 젖산 및 에탄올의 동시 측정용 바이오센서의 개발 (Development of Biosensor for Simultaneous Determination of Glucose, Lactic Acid and Ethanol)

  • 김정호;이동희;김태진;노봉수
    • 한국식품과학회지
    • /
    • 제30권1호
    • /
    • pp.22-34
    • /
    • 1998
  • 고정화효소와 산소전극 시스템을 이용한 효소센서를 제작하여 식품 중의 당, 유기산, 알코올 성분을 동시 측정 하였다. 효소가 기질과 반응하여 소비한 산소의 변화량이 전압차이로 나타나므로 시간당 전압 감소량이 최대인 값으로부터 각 성분의 농도를 측정하였으며, 이때 1분내에 최대기울기를 구할 수 있어 신속한 측정이 가능하였다. 효소의 고정화 지지체로는 nylon cloth를 사용하였고, asymmetrical coupling 방법에 의하여 기질 작용 순으로 위치하도록 효소를 고정화하였다. 한 개의 양극과 6개의 음극으로 제작된 multiple cathode system으로 포도당, 젖산, 에탄올 성분을 동시 측정할 수 있는 효소 센서를 제작하였다. 위의 센서 제작을 위하여 mutarotase과 glucose oxidase/lactate oxidase/alcohol oxidase와 catalase가 각기 사용되었다. 이들 효소센서의 최적조건은 $pH\;7.0,\;40^{\circ}C$의 0.1 M 인산완충용액이었으며 각 효소 센서의 방해물질을 알아 보기 위하여 여러 가지 당과 각종 유기산, 알콜류에 대한 효소 감응도를 살펴 본 결과 포도당 센서에서 유기산의 영향을 제외하고는 10% 내외였다. 따라서 포도당과 유기산을 동시 측정하기 위하여 포도당/젖산의 영향을 고려한 적절한 보정관계식을 도입하여 순수한 유리당과 유기산의 값을 측정할 수 있었다. 제작된 효소센서의 검증을 위하여 분광광도법. HPLC, GC를 이용한 결과, 분석방법간에 높은 상관관계를 보여 주었다. 아울러 각 효소센서의 안정성을 살펴본 결과 알코올 센서를 제외하고는 30일 이후에도 80%이상 효소감응도가 유지되었다.

  • PDF

효소 전극을 이용한 유산균 측정 바이오센서 개발 (Development of an Enzyme Electrode Biosensor for Lactic Acid Bacteria)

  • 박두산;조성인
    • Journal of Biosystems Engineering
    • /
    • 제30권4호
    • /
    • pp.249-253
    • /
    • 2005
  • This study was carried out to develop enzyme biosensor for lactic acid bacteria. Lactic acids produced by lactic acid bacteria (LAB) was measured and good correlation $R^2=0.98$ between LAB count and lactic acids concentration was found. Hydrogen ion produced by L-lactate dehydrogenase (L-LDH) was measured by a potentiometer. Glutamic-pyruvic transminase (GPT) was used for eliminating inhibitor in the reaction. Polyacrylamide gel was used for immobilizing matrix of the sensor. The biosensor was tested and showed good feasibility with $R^2=0.99$ on validation.