• Title/Summary/Keyword: Lab On a Chip

Search Result 198, Processing Time 0.024 seconds

Design of a Portable Activity Monitoring System (휴대용 활동 상태 모니터링 시스템의 설계)

  • Lee, Seung-Hyung;Park, Ho-Dong;Yoon, Hyung-Ro;Lee, Kyung-Joung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.1
    • /
    • pp.32-38
    • /
    • 2002
  • This paper describes a development of a portable physical activity monitoring system using two accelerometers to quantify physical activity. The system hardware consists of two piezoresistive accelerometers, amplifiers with gain of 30, lowpass filters with cut-off frequency of 15Hz, offset control circuits, one-chip microcontroller and flash memory card. In order to evaluate the performance of the system we acquired 3 channel data at 32 sample/sec from body-fixed accelerometers in chest and right upper leg. And then the acquired data were processed by MatLab on personal computer. We tried to distinguish not only fundamental actions which are steady-state activities such as standing, sitting, and lying but also dynamic activities with walking, up a stairway, down a stairway, and running. Five subjects participated the evaluation process which compare the video data with the measured data. As a result, the activity classification rate of 90.6% on average was obtained. Overall results showed that the steady-state activities could be classified from the low component of 3-axis acceleration signal and dynamic activities could be distinguished from frequency analysis using wavelet transform and FFT. Finally, we could find that this system can be applied to acquire and analyze the static and dynamic physical activity data.

Nano and micro structures for label-free detection of biomolecules

  • Eom, Kil-Ho;Kwon, Tae-Yun;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.403-420
    • /
    • 2010
  • Nano and micro structure-based biosensors are promising tool for label-free detection of biomolecular interactions with great accuracy. This review gives a brief survey on nano and micro platforms to sense a variety of analytes such as DNA, proteins and viruses. Among incredible nano and micro structure for bio-analytical applications, the scope of this paper will be limited to micro and nano resonators and nanowire field-effect transistors. Nanomechanical motion of the resonators transducers biological information to readable signals. They are commonly combined with an optical, capacitive or piezo-resistive detection systems. Binding of target molecule to the modified surface of nanowire modulates the current of the nanowire through electrical field-effect. Both detection methods have advantages of label-free, real-time and high sensitive detection. These structures can be extended to fabricate array-type sensors for multiplexed detection and high-throughput analysis. The biosensors based on these structures will be applied to lab-on-a-chip platforms and point-of-care diagnostics. Basic concepts including detection mechanisms and trends in their fields will be covered in this review.

Inductor-less 6~18 GHz 7-Bit 28 dB Variable Attenuator Using 0.18 μm CMOS Technology (0.18 μm CMOS 기반 인덕터를 사용하지 않는 6~18 GHz 7-Bit 28 dB 가변 신호 감쇠기)

  • Na, Yun-Sik;Lee, Sanghoon;Kim, Jaeduk;Lee, Wangyoung;Lee, Changhoon;Lee, Sungho;Seo, Munkyo;Lee, Sung Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.60-68
    • /
    • 2016
  • This paper presents a 6~18 GHz 7-bit digital-controlled attenuator. The proposed attenuator is based on switched-T architecture, but no inductor is used for minimum chip size. The designed attenuator was fabricated using $0.18{\mu}m$ CMOS process, and characterized using on-wafer testing setup. The resolution(minimum attenuation step) and the maximum attenuation range of the attenuator were measured to be 0.22 dB and 28 dB, respectively. The measured RMS attenuation error and the RMS phase error for 6~18 GHz were less than 0.26 dB and $3.2^{\circ}$, respectively. The reference state insertion loss was less than 12.4 dB at 6~18 GHz. The measured input and output return losses were better than 9.4 dB over all frequencies and attenuation states. The chip size is $0.11mm^2$ excluding pads.

Simple Identification Methods for Unknown Suspicious White Powders using Microfluidic-based Platform (미세유체 기반의 플랫폼을 이용한 미지의 백색가루 간이식별 탐지방안)

  • Park, Jae Woo;Song, Jiyoung;Na, Sang Cheol;Byun, Kisik;Jeon, Noo Li
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.853-859
    • /
    • 2017
  • Terrorists always threats the global security with the possibility of using prohibited warfare, NBCs(Nuclear, Biological and Chemical Warfare). Compared to other prohibited warfares, most of biological warfare agents (BWAs) have no physical properties and time delays from spread to affect. Therefore the early detection is important to protect and decontaminate from BWAs. On the preliminary detection stage for suspicious material, most of detection kits only serve to know weather the BWAs exists or not. Due to this reason, simple field confirmation testing for suspicious substances have been used to identify materials which show negative result on detection kits. Considering the current Lab on a Chip(LOC) technologies, we suggest simple identification platform for unknown suspicious substances based on paper fluidics. We hope that our research will envision the future direction for the specific point-of-view for LOC technologies on detection strategy of BWAs.

In situ analysis of capturing dynamics of magnetic nanoparticles in a microfluidic system

  • Munir, Ahsan;Zhu, Zanzan;Wang, Jianlong;Zhou, H. Susan
    • Smart Structures and Systems
    • /
    • v.12 no.1
    • /
    • pp.1-22
    • /
    • 2013
  • Magnetic nanoparticle based bioseparation in microfluidics is a multiphysics phenomenon that involves interplay of various parameters. The ability to understand the dynamics of these parameters is a prerequisite for designing and developing more efficient magnetic cell/bio-particle separation systems. Therefore, in this work proof-of-concept experiments are combined with advanced numerical simulation to design and optimize the capturing process of magnetic nanoparticles responsible for efficient microfluidic bioseparation. A low cost generic microfluidic platform was developed using a novel micromolding method that can be done without a clean room techniques and at much lower cost and time. Parametric analysis using both experiments and theoretical predictions were performed. It was found that flow rate and magnetic field strength greatly influence the transport of magnetic nanoparticles in the microchannel and control the capturing efficiency. The results from mathematical model agree very well with experiments. The model further demonstrated that a 12% increase in capturing efficiency can be achieved by introducing of iron-grooved bar in the microfluidic setup that resulted in increase in magnetic field gradient. The numerical simulations were helpful in testing and optimizing key design parameters. Overall, this work demonstrated that a simple low cost experimental proof-of-concept setup can be synchronized with advanced numerical simulation not only to enhance the functional performance of magneto-fluidic capturing systems but also to efficiently design and develop microfluidic bioseparation systems for biomedical applications.

Flow Visualization of the Flow inside the Droplet Passing through a Straight and a Diverging Channel (직선채널과 확대채널에서의 액적 내부 유동 가시화)

  • Jin, Byung-Ju;Kim, Young-Won;Yoo, Jung-Yul
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.71-76
    • /
    • 2007
  • Flow visualization of a droplet passing through a straight channel and a diverging channel has been carried out using micro-PIV. Diverging channel is frequently used in lab-on-a-chip and microfluidic devices, where flow pattern inside the droplet passing is quite different from that through a straight channel. In the present study, we visualized the droplet flow in three different regions. The first region is where the droplet has a wide contact area with the channel wall, the second region is characterized with a narrow contact area and the third region is where droplet is detached from the channel wall. Visualization results show that the internal flow inside the droplet passing through the straight channel moves in the opposite direction to the droplet velocity in the near wall exhibiting complex flow patterns. But in the diverging channel the internal flow inside the droplet moves in the same direction as the droplet velocity due to the shear induced by oil phase flow exhibiting rather simple flow pattern.

  • PDF

A DNA Microextractor Using Crossed Field Electrophoresis (교차 전기영동법을 이용한 극소형 DNA 추출기)

  • Yi Soyeon;Seo Kyoung-Sun;Cho Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.8 s.227
    • /
    • pp.1135-1139
    • /
    • 2004
  • This paper presents a microextractor for the separation of DNA molecules by their sizes. The DNA microextractor immobilizes the DNA molecules of specific size in the micropillar array by adjusting the period of the crossed electric field, thus providing a starting-point independent target DNA extraction method without separation process monitoring. The DNA microextractor has been fabricated by a three-mask micromachining process. The velocity of three different DNA molecules has been measured at the electric field of E=5V/0.8cm in the fabricated DNA microextractor, resulting in the reorientation times of $4.80{\pm}0.44sec,\;7.12{\pm}0.75sec$, and $9.88{\pm}0.30sec$ for ${\lambda}$ DNA, micrococcus DNA, and T4 DNA, respectively. T4 DNA is trapped in the micropillar array when the crossed electric field of 5V/0.8cm is applied alternately at a 10 second time interval. The present DNA microextractor filters the DNA in a specific size range by adjusting the magnitude and/or the period of the crossed electric field applied in the micropillar array.

Micro-LIF measurement of microchannel flow

  • Kim Kyung Chun;Yoon Sang Youl
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.65-74
    • /
    • 2004
  • Measurement of concentration distributions of suspended particles in a micro-channel is out of the most crucial necessities in the area of Lab-on-a-chip to be used for various bio-chemical applications. One most feasible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been successfully achieved so far due to various limitations in the light illumination and fluorescence signal detection. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having five(5) microns thickness by use of a micro focus laser line generator. The laser sheet beam illuminates an exact plane of concentration measurement field to increase the signal to noise ratio and considerably reduce the depth uncertainty. Nile Blue A was used as fluorescent dye for the present LIF measurement. The enhancement of the fluorescent intensity signals was performed by a solvent mixture of water $(95\%)$ and ethanol (EtOH)/methanol (MeOH) $(5\%)$ mixture. To reduce the rms errors resulted from the CCD electronic noise and other sources, an expansion of grid size was attempted from $1\times1\;to\;3\times3\;or\;5\times5$ pixel data windows and the pertinent signal-to-noise level has been noticeably increased accordingly.

  • PDF

Study on flow behavior of polymer solutions in microchannels (미세구조 내에서의 사출성형 흐름에 관한 연구)

  • Kim Dong-Hak;Xu Guojun;Koelling Kurt W.;Lee L.James
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.471-475
    • /
    • 2006
  • Filling the microchannels is very important in designing micro-injection molding, microdevices, etc. In this paper, flow dynamics was studied in injection molding with microchannels. A transparent PMMA mold was designed and the flow dynamics was observed. The experiment was performed using poly (ethylene oxide) (PEO) and polyacrylamide (PA) aqueous solutions. The transignt dynamic flow and flow competition between the base plate and the microchannels were observed. The flow observation was used to explain previous filling length results in microchannels during micro-injection molding.

  • PDF

Cytocompatible Coating of Individual Mammalian Cells with Tannic Acid-Zn Complex (타닌산-아연 복합체를 이용한 단일수준에서의 동물세포 코팅)

  • Lee, Juno
    • KSBB Journal
    • /
    • v.32 no.2
    • /
    • pp.160-167
    • /
    • 2017
  • Coating of individual cells with organic or inorganic materials has drawn a great deal of attention, because it provides the cells with physicochemical durability, which would contribute to the development of bioreactors, biosensor, and lab-on-a-chip, as well as to the fundamental studies in single cell-based biology. Although many strategies have been developed for coating of microbial cells, limited methods are available to coat mammalian cells because most mammalian cells do not have a robust membrane or exoskeleton. Instead, they are enclosed in a lipid bilayer, which is fluidic and vulnerable to changes in its environments. It is more difficult to treat mammalian cells in vitro than microbial cells because the surfaces of mammalian cells are not protected or reinforced by a tough coat. In this work, we report a cytocompatible and degradable nanocoat for mammalian cells. Three types of mammalian cells (HeLa cells, NIH 3T3 fibroblasts, and Jurkat T cells) were individually coated within metal-polyphenol. To maintain the viability of the mammalian cells, we performed the whole processes under strictly physiological culture conditions, and carefully selected nontoxic materials.