3상 계통 연계 인버터의 SVPWM을 위한 LCL-필터 설계 (Design of an LCL-Filter for Space Vector PWM in a Grid-Connected System)

  • 서승규;조용수;이교범
    • 전력전자학회논문지
    • /
    • 제21권6호
    • /
    • pp.538-541
    • /
    • 2016
  • This paper proposes an LCL-filter design for space vector pulse width modulation (SVM) in grid-connected three-phase inverter systems. Although there are a several studies in progress, the existing methods are erroneous because they do not focus on the other switching methods. This paper presents the design methodology for an LCL-filter that is optimized for SVM switching operations. The design procedure for the LCL-filter is presented step-by-step. The inverter-side inductor was determined by an analysis of the ripple components, mathematically. Based on the reactive power absorption ratio, the filter capacitor was determined. The grid-side inductor was determined by the ripple attenuation factor of the output current. Experimental results verify the validity of the design method for the LCL-filter.

교류 입력측 LCL 필터 구조 전압형 PWM 컨버터의 설계 (Design of Voltage Source PWM Converter with AC Input LCL Filter)

  • 노재석;최재호
    • 전력전자학회논문지
    • /
    • 제7권5호
    • /
    • pp.490-498
    • /
    • 2002
  • 본 논문에서는 전압형 PWM 컨버터의 교류 입력측 LCL 필터의 설계기법을 제안한다 기존의 전압형 PWM 컨버터에서 전원계통으로 흘러 들어가는 스위칭 고조파전류를 억제하기 위해 교류 입력측에 LCL 필터를 설치하는 것은 매우 경제적이고 효과적인 방법이다 필터 커패시터로 스위칭 고조파전류를 흡수하며 공진을 억제하기 위해 수동 댐핑 저항을 이용한다 UPS용의 LCL 필터 구조 PWM 컨버터의 설계예시를 보였으며 제안한 설계기법의 타당성을 입증하기 위해 PSIM을 이용한 시뮬레이션을 행하였다.

계통연계형 인버터에서 대칭 구조를 갖는 LCL 필터 설계 및 제어 (Design of an LCL Filter employing a Symmetric Geometry and its Control in Grid-connected Inverter Applications)

  • 이귀준;박남주;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.250-252
    • /
    • 2008
  • An inductor-capacitor-inductor (LCL) filter are widely adapted in grid-connected inverter applications. In this paper, the harmonic attenuations of the LCL filter are quantitatively analyzed, and then the design optimization of two inductance values, which are related on a cost and a size, is illustrated. Based on the design optimization, the LCL filter employing a Symmetric Geometry is proposed. Through the equivalent circuit analysis of the proposed LCL filter, the operating characteristics and validity are presented in detail. In addition, simple proportional-integral (PI) current controller suitable for the LCL Filter is designed to mitigate the resonance problem. From simulation results, it is seen that the proposed LCL filter and control method have a sufficient attenuation and stability for the high frequency distortions and load variations.

  • PDF

계통연계형 인버터의 LCL필터 최적 설계기법 (Optimized LCL filter Design Method of Utility Interactive Inverter)

  • 정상혁;최세완
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.

계통 연계 3상 인버터를 위한 LCL 필터 설계 및 EMTP-RV 시뮬레이션 연구 (A Study on LCL Filter Design and EMTP-RV Simulation for Grid-connected Three Phase Inverter)

  • 고윤석
    • 한국전자통신학회논문지
    • /
    • 제16권2호
    • /
    • pp.261-270
    • /
    • 2021
  • 본 연구에서는 계통 연계 3상 인버터를 위한 LCL 필터를 설계 방법론을 연구하였다. 먼저, 대표적인 필터 구조들에 대해서 3상 인버터의 계통 연계를 위한 필터로서의 적용 시 장단점을 분석하였다. 다음, 3상 인버터의 계통 연계를 위한 필터 설계 방법론들을 분석하여 그리드 연계 시 고조파 요구 조건을 만족할 수 있는 효과적인 필터 설계 방법론을 결정하였다. 그리고 설계 방법론의 유효성을 확인하기 위해서 EMTP-RV를 이용하여 3상 인버터, LCL 필터 그리고 필터의 성능을 평가하기 위한 성능 평가 시스템을 모델링 하였다. 끝으로, 하나의 3상 인버터에 대한 LCL 필터를 설계하였으며, EMTP-RV 시뮬레이션 작업을 통해 3상 인버터의 출력 전류 리플의 크기가 제한됨을 확인함으로서 설계 방법론의 유효성을 검증할 수 있었다.

DPWM 방식을 적용한 3상 계통 연계 인버터의 LCL-필터 설계 (Design of LCL-filter for Grid-Connected Three-Phase Inverters Using a Discontinuous PWM Method)

  • 이정록;서승규;이교범
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.419-427
    • /
    • 2016
  • This paper proposes a design method of LCL-filter for a grid-connected three-phase inverter using a discontinuous PWM (DPWM) method. When using a DPWM method, many harmonic voltages are generated in the inverter output compared to a continuous PWM (CPWM) method. Therefore, an optimized grid-connected filter design is required for a DPWM method. The proposed design method provides generalized formula to design accurate LCL-filter without trial and error procedures. An inverter side inductance is designed by analyzing the current ripple injected to the grid. The Optimized parameters of LCL-filter can be designed by analyzing the total harmonic distortion (THD) and the ripple attenuation factor of the output current. The proposed LCL filter design method is demonstrated by simulation and experimental results.

Design of an LCL-Filter for Three-Parallel Operation of Power Converters in Wind Turbines

  • Jeong, Hae-Gwang;Yoon, Dong-Keun;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.437-446
    • /
    • 2013
  • This paper proposes a design scheme for an LCL-filter used for the three-parallel operation of the power converters in high-capacity wind turbines. The designs of the power devices and grid connected filter are difficult due to the high level voltages and currents in huge-capacity wind turbines. To solve these problem, this paper presents three-parallel operation and LCL-filter design techniques optimized by parallel operation. Furthermore, the design of an inverter side inductance of the LCL-filter is discussed in detail considering the switching modulation method. Simulation and experimental results demonstrate the validity of the designed filter and wind turbines.

계통 연계형 3-레벨 인버터 시스템을 위한 LCL-필터 설계 방법 (Design of an LCL-Filter for Grid-Connected Three-Level Inverter System)

  • 박준영;김석민;서승규;박성수;이교범
    • 전기전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.105-114
    • /
    • 2017
  • 본 논문은 계통 연계형 3-레벨 인버터 시스템을 위한 LCL-필터 설계 방법을 제안한다. 최근 풍력 및 태양광과 같은 신재생에너지 발전 시스템을 위한 3상 PWM 인버터의 수요가 증가하고 있다. 이러한 PWM 인버터는 스위칭 동작에 의해 발생하는 고조파 성분을 제거하기 위하여 LCL-필터를 거쳐 계통과 연결된다. 필터 설계에 관한 다양한 연구가 진행되었지만 최소의 사이즈로 목표하는 고조파 제거 성능을 얻기 위해서는 해당 PWM 인버터의 스위칭 방법을 고려한 필터 설계 방법이 요구된다. 본 논문은 공간 전압벡터 변조기법(SVPWM)에 최적화된 LCL-필터 설계방법을 제시한다. 시뮬레이션과 실험 결과를 통해 제안하는 방법으로 설계된 LCL-필터의 성능을 검증한다.

LCL Filter Design Method for Grid-Connected PWM-VSC

  • Majic, Goran;Despalatovic, Marin;Terzic, Bozo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1945-1954
    • /
    • 2017
  • In recent years, several LCL filter design methods for different converter topologies have been published, many of which use analytical expressions to calculate the ideal converter AC voltage harmonic spectrum. This paper presents the LCL filter design methodology but the focus is on presentation and validation of the non-iterative filter design method for a grid-connected three-phase two-level PWM-VSC. The developed method can be adapted for different converter topologies and PWM algorithms. Furthermore, as a starting point for the design procedure, only the range of PWM carrier frequencies is required instead of an exact value. System nonlinearities, usually omitted from analysis have a significant influence on VSC AC voltage harmonic spectrum. In order to achieve better accuracy of the proposed procedure, the system nonlinear model is incorporated into the method. Optimal filter parameters are determined using the novel cost function based on higher frequency losses of the filter. An example of LCL filter design for a 40 kVA grid-connected PWM-VSC has been presented. Obtained results have been used to construct the corresponding laboratory setup and measurements have been performed to verify the proposed method.

Co-design of the LCL Filter and Control for Grid-Connected Inverters

  • Zhang, Yu;Xue, Mingyu;Li, Minying;Kang, Yong;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.1047-1056
    • /
    • 2014
  • In most grid-connected inverters (GCI) with an LCL filter, since the design of both the LCL filter and the controller is done separately, considerable tuning efforts have to be exerted when compared to inverters using an L filter. Consequently, an integrated co-design of the filter and the controller for an LCL-type GCI is proposed in this paper. The control strategy includes only a PI current controller and a proportional grid voltage feed-forward controller. The capacitor is removed from the LCL filer and the design procedure starts from an L-type GCI with a PI current controller. After the PI controller has been settled, the capacitor is added back to the filter. Hence, it introduces a resonance frequency, which is identified based on the crossover frequencies to accommodate the preset PI controller. Using the proposed co-design method, harmonic standards are satisfied and other practical constraints are met. Furthermore, the grid voltage feed-forward control can bring an inherent damping characteristic. In such a way, the good control performance offered by the original L-type GCI and the sharp harmonic attenuation offered by the latter designed LCL filter can be well integrated. Moreover, only the grid current and grid voltage are sensed. Simulation and experimental results verify the feasibility of the proposed design methodology.