• Title/Summary/Keyword: L-Mode

Search Result 1,516, Processing Time 0.022 seconds

Building Blocks for Current-Mode Implementation of VLSI Fuzzy Microcontrollers

  • Huerats, J.L.;Sanchez-Solano, S.;Baturone, I.;Barriga, A.
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.929-932
    • /
    • 1993
  • A fuzzy microcontroller is presented implementing a simplified inference mechanism. Fuzzification, rule composition and defuzzification are carried out by means of (basically) analog current-mode CMOS circuits operating in strong inversion. Also a voltage interface is provided with the external world. Combining analog and digital techniques allow a programming capability.

  • PDF

Photonic Quasi-crystal Fiber for Orbital Angular Momentum Modes with Ultra-flat Dispersion

  • Kim, Myunghwan;Kim, Soeun
    • Current Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.298-303
    • /
    • 2019
  • We propose a photonic quasi-crystal fiber (PQF) for supporting up to 14 orbital angular momentum (OAM) modes with low and ultra-flat dispersion characteristics over the C+L bands. The designed PQF which consists of a large hollow center and quasi structural small air holes in the clad region exhibits low confinement losses and a large effective index separation (>$10^{-4}$) between the vector modes. This proposed fiber could potentially be exploited for mode division multiplexing and other OAM mode applications in fibers.

Design of the RF Front-end for L1/L2 Dual-Band GPS Receiver (L1/L2 이중-밴드 GPS 수신기용 RF 전단부 설계)

  • Kim, Hyeon-Deok;Oh, Tae-Soo;Jeon, Jae-Wan;Kim, Seong-Kyun;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.10
    • /
    • pp.1169-1176
    • /
    • 2010
  • The RF front-end for L1/L2 dual-band Global Positioning System(GPS) receiver is presented in this paper. The RF front-end(down-converter) using low IF architecture consists of a wideband low noise amplifier(LNA), a current mode logic(CML) frequency divider and a I/Q down-conversion mixer with a poly-phase filter for image rejection. The current bleeding technique is used in the LNA and mixer to obtain the high gain and solve the head-room problem. The common drain feedback is adopted for low noise amplifier to achieve the wideband input matching without inductors. The fabricated RF front-end using $0.18{\mu}m$ CMOS process shows a gain of 38 dB for L1 and 41 dB for L2 band. The measured IIP3 is -29 dBm in L1 band and -33 dBm in L2 band, The input return loss is less than -10 dB from 50 MHz to 3 GHz. The measured noise figure(NF) is 3.81 dB for L1 band and 3.71 dB for L2 band. The image rejection ratio is 36.5 dB. The chip size of RF front end is $1.2{\times}1.35mm^2$.

A Numerical Study of Hydraulic Fractures Propagation with Rock Bridges (Rock bridges를 고려한 수치 해석적 수압파쇄 균열거동 연구)

  • 최성웅
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2000.09a
    • /
    • pp.201-210
    • /
    • 2000
  • Rock bridge in rock masses can be considered as one of several types of opening-mode fractures, and also it has been known to have a great influence on the stability of structures in rock mats. In the beginning of researching a rock bridge it used to be studied only in characteristics of its behavior, as considering resistance of material itself. However the distribution pattern of rock bridges, which can affect the stability of rock structures, is currently researched with a fracture mechanical approach in numerical studies. For investigating the effect of rock bridges on the development pattern of hydraulic fractures, the author analyzed numerically the stress state transition in rock bridges and their phenomena with a different pattern of the rock bridge distributons. From the numerical studies, a two-crack configuration could be defined to be representative of the most critical conditions for rock bridges, only when cracks are systematic and same in their length and angle. Moreover, coalescence stresses and onset of propagation stresses could be known to increase with decreasing s/L ratio or increasing d/L ratio. The effect of pre-existing crack on hydraulic fracturing was studied also in numerical models. Different to the simple hydraulic fracturing modeling in which the fractures propagated exactly parallel to the maximum remote stress, the hydraulic fractures with pre-existing cracks dial not propagate parallel to the maximum remote stress direction. These are representative of the tendency to change the hydraulic fractures direction because of the existence of pre-existing crack. Therefore s/L, d/L ratios will be identical as a function effective on hydraulic fractures propagation, that is, the $K_{I}$ vague increase with decreasing s/L ratio or increasing d/L ratio and its magnification from onset to propagation increases with decreasing s/L ratio. The scanline is a commonly used method to estimate the fracture distribution on outcrops. The data obtained from the scanline method can be applied to the evaluation of stress field in rock mass.s.

  • PDF

Influence of the random fluctuation in grating period on the Coupling Coefficient of QWS-DFB Lasers (회절격자 주기의 랜덤 변이가 QWS-DFB 레이저의 정규화된 결합계수에 미치는 영향)

  • Ha, Seon-Yong;Kim, Sang-Bae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.9
    • /
    • pp.624-633
    • /
    • 2001
  • Influence of the grating half-period fluctuation on the normalized coupling coefficient has been studied by an effective index transfer matrix method in quarter wavelength shifted(QWS) DFB lasers. The laser facets are assumed to be perfectly antireflection coated, and the period fluctuation is modeled by two correlated Gaussian random variables. In the presence of the random fluctuation in the grating period, effective normalized coupling coefficient is reduced because the in-phase feedback strength Is weakened. We have shown that the normalized coupling coefficient determined from the side mode spacing is less than the effective coupling coefficient, and the normalized coupling coefficient determined from the mode spacing or spontaneous emission spectrum does not properly represent the feedback strength of the grating.

  • PDF

Decreased Voltage Dependent $K^+$ Currents in Cerebral Arterial Smooth Muscle Cells of One-Kidney, One-Clip Goldblatt Hypertensive Rat

  • Oh, Young-Sun;Kim, Se-Hoon;Kim, Hoe-Suk;Jeon, Byeong-Hwa;Chang, Seok-Jong;Kim, Kwang-Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.5
    • /
    • pp.471-479
    • /
    • 1999
  • The Kv channel activity in vascular smooth muscle cell plays an important role in the regulation of membrane potential and blood vessel tone. It was postulated that increased blood vessel tone in hypertension was associated with alteration of Kv channel and membrane potential. Therefore, using whole cell mode of patch-clamp technique, the membrane potential and the 4-AP-sensitive Kv current in cerebral arterial smooth muscle cells were compared between normotensive rat and one-kidney, one-clip Goldblatt hypertensive rat (lK,lC-GBH rat). Cell capacitance of hypertensive rat was similar to that of normotensive rat. Cell capacitance of normotensive rat and 1K,lC-GBH rat were $20.8{\pm}2.3$ and $19.5{\pm}1.4$ pF, respectively. The resting membrane potentials measured in current clamp mode from normotensive rat and 1K,lC-GBH rat were $-45.9{\pm}1.7$ and $-38.5{\pm}1.6$ mV, respectively. 4-AP (5 mM) caused the resting membrane potential hypopolarize but charybdotoxin $(0.1\;{\mu}M)$ did not cause any change of membrane potential. Component of 4-AP-sensitive Kv current was smaller in 1K,lC-GBH rat than in normotensive rat. The voltage dependence of steady-state activation and inactivation of Kv channel determined by using double-pulse protocol showed no significant difference. These results suggest that 4-AP-sensitive Kv channels playa major role in the regulation of membrane potential in cerebral arterial smooth muscle cells and alterations of 4-AP-sensitive Kv channels would contribute to hypopolarization of membrane potential in 1K,lC-GBH rat.

  • PDF

A study on the Empirical Design of EMI Filters for Power Supply Noise Reduction in Electronic Devices (전자기기의 전원 노이즈 저감을 위한 EMI 필터 경험적 설계에 관한 연구)

  • Yun-Min Lee;Jin-Seob, Shin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.59-64
    • /
    • 2023
  • In this paper, It is proposed through the empirical design of a Conducted EMI filter for noise reduction of power used in electronic devices. For the proposed structure, A-type, B-type, C-type, and D-type structures were designed, and conductive noise reduction was confirmed by using an LC network with various X-capacitors, Y-capacitors, and Air-inductors. 10 [μH] was used for L1 and L2, and 4.7 [nF] was used for C1 and C2. L3 for common mode used 13[μH], and C5, C6, C7 were designed using 10[nF]. The measured insertion loss values of the designed EMI filter were -74.4[dB] at 3.2MHz, -75.4[dB] at 4MHz, and -75.3[dB] at 13.56MHz. Therefore, the proposed EMI filter will be able to reduce power supply noise used in various electronic devices.

A Bidirectional Three-phase Push-pull Zero-Voltage Switching DC-DC Converter (양방향 3상 푸쉬풀 ZVS DC-DC 컨버터)

  • Kwon, Min-Ho;Han, Kook-In;Park, Jung-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.403-411
    • /
    • 2013
  • This paper proposes an isolated bidirectional three-phase push-pull dc-dc converter for high power application such as eco-friendly vehicles, renewable energy systems, energy storage systems, and solid-state transformers. The proposed converter achieves ZVS turn-on of all switches and volume of passive components is small by an effect of three-phase interleaving. The proposed converter has identical switching pattern for both boost and buck mode, and therefore can provide seamless characteristic at the mode transition. A 3kW prototype of the proposed converter has been built and tested to verify the validity of the proposed operation.

Morningside Pi2 Pulsation Observed in Space and on the Ground

  • Ghamry, Essam
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.305-310
    • /
    • 2015
  • In this study, we examined a morningside Pi2 pulsation, with a non-substorm signature, that occurred in very quiet geomagnetic conditions (Kp = 0) at 05:38 UT on December 8, 2012, using data obtained by Van Allen Probes A and B (VAP-A and VAP-B, respectively) and at a ground station. Using 1 sec resolution vector magnetic field data, we measured the X-component of the pulsation from the Abu Simbel ground station (L = 1.07, LT = UT +2 hr, where LT represents local time) in Egypt. At the time of the Pi2 event, Abu Simbel and VAP-A (L = 3.3) were in the morning sector (07:38 LT and 07:59 MLT, respectively, where MLT represents magnetic local time), and VAP-B was in the postmidnight sector (04:18 MLT and L = 5.7). VAP-A and VAP-B observed oscillations in the compressional magnetic field component (Bz), which were in close agreement with the X-component measurements of the Pi2 pulsation that were made at Abu Simbel. The oscillations observed by the satellites and on the ground were in phase. Thus, we concluded that the observed morningside Pi2 pulsation was caused by the cavity resonance mode rather than by ionospheric current systems.

Development of 3kW Hybrid ESS with Function of Emergency Power Supply (비상전원 기능을 갖는 3kW급 하이브리드 ESS 개발)

  • Yang, Seok-Hyun;Kim, Min-Jae;Choi, Se-Wan;Cho, Jun-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 2015
  • This paper proposes a high-efficiency 3-kW hybrid ESS with emergency power supply. The proposed system enables efficient use of power from photovoltaic (PV) cells and energy storage system (ESS). The proposed system can operate as an uninterruptible power supply (UPS) when grid fault occurs, providing seamless transfer from grid-connected mode to stand-alone mode. The LLC converter for PV achieves ZVS turn-on of switches and ZCS turn-off of diodes, and the isolated bidirectional DC-DC converter for ESS achieves ZCS turn-off regardless of load condition, resulting in high efficiency. The efficiency and performance of the proposed hybrid ESS has been verified by a 3-kW prototype.