• Title/Summary/Keyword: L-C filter

Search Result 278, Processing Time 0.027 seconds

A Novel Filter Design for Output LC Filters of PWM Inverters

  • Kim, Hyo-Sung;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.74-81
    • /
    • 2011
  • The cutoff frequency of the output LC filters of PWM inverters limits the control bandwidth of the converter system while it attenuates voltage ripples that are caused by inverter switching activities. For a selected cutoff frequency of an output LC filter, an infinite number of L-C combinations is possible. This paper analyses the characteristics of output LC filters for PWM inverters terms of the L-C combinations. Practical circuit conditions such as no-loads, full resistive-loads, and inductive-load conditions are considered in the analysis. This paper proposes a LC filter design method for PWM inverters considering both the voltage ynamics and he inverter stack size. An experimental PWM inverter system based on the proposed output LC lter design uideline is built and tested.

A study of power filter for conversion of 3 phase PWM waveform to grid power line (전력용 3상 PWM 파형의 상용전원 변환용 Filter 연구)

  • Yea, Hwan-Je;Sea, Young-Taek;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1016-1019
    • /
    • 1993
  • A low-pass L-C filter has been adopted for conversion of frequency variable 3 phase PWM waveform to a grid power line and it is used for attenuation of harmonics in the VSI PWM Inverter. A optimum design of the L, C parameters was derived. The result of the study show that the inductor L seems to have a certain air gap for linear I-V characteristics and the resonant frequency of the filter must be set below the 5th harmonics of the grid power line. Further, the voltage drop in L must be within a adequate limit compared to grid power voltage.

  • PDF

Design of Lowpass Filter With the Wide Stopband Characteristics Using Microstrip Line (마이크로스트립 선로를 이용한 광대역 차단특성을 가지는 저역통과 필터 설계)

  • Choi Dong-Muk;Shim Joon-Hwan;Jeon Joongn-Sung;Kim Dong-Il
    • Journal of Navigation and Port Research
    • /
    • v.30 no.5 s.111
    • /
    • pp.331-334
    • /
    • 2006
  • In this paper, we designed and fabricated the lowpass filter with the wide stopband characteristics using microp- strip line. Adding the $\lambda_g/4$ open stub at the input and output ports, we developed the L-C ladder type lowpass filter using the open stub which has wide stopband characteristics. In order to reduce the entire size qf this filter, the high impedance microstrip lines were made with the meander structure. The lowpass filter was fabricated with the cutoff frequency 2.3 GHz and its measured frequency responses agree well with the simulation results.

Design and Fabrication of a Surge Protective Device for Electrical Mains on Shipboard (전원회로용 서지방호장치의 설계 및 제작)

  • Moon, Seung-Bo;Park, Dae-Won;Song, Jae-Yong;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1035-1040
    • /
    • 2005
  • This paper deals with the design rule and performance results of the surge protective devices (SPDs) for low-voltage mains on shipboard. The proposed SPDs consists of a metal oxide varistors (MOV) and a L-C filter to improve noise-elimination performance. Three kinds of SPDs are fabricated and tested by using a combination surge generator which produce the standard impulse current of 8/20${\mu}s$ 2.1kA. As a results, the proposed SPDs with series L-C filter have more excellent transient blocking and noise reduction performance than the conventional ones.

  • PDF

Analysing and comparing efficiency of harmonic reduction equipment for Induction Motor (유도전동기의 고조파 저감장치 성능 비교 분석)

  • Park, Yang-Birm;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.47-52
    • /
    • 2005
  • Recently, power conversion equipment increased rapidly makes a lot of harmonics. Thus, it is growing that wrong operation and break down of sensitive devices. There are two kinds of causes of harmonics. One of them is lots of power conversion equipment as modem controller, inverter, converter and SWS(Switching Mode Power Supply). Another is nonlinear operating machines as transformer and motor. The more nonlinear loads like them grow, the more serious problems as harmonic current to source and low power factor because of increasing reactive power grow. It is installed for reactor and L-C Filter to decrease harmonic in general. This paper analysis and compares two of characteristics and harmonic from reactor and L-C Filter with operation of induction motor and power conversion equipment. In the result, L-C Filter more improves unbalance rate and THD than reactor.

Evaluation of Swine Wastewater Pretreatment Using Anaerobic Filter (Anaerobic Filter에 의한 양돈폐수의 전처리 특성 평가)

  • Kang, Ho;Moon, Seo-yeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.7
    • /
    • pp.418-425
    • /
    • 2015
  • Anaerobic Filters (AF) packed with porous ceramic floating media were operated at different operational conditions to identify the feasibility of the renewable bioenergy, methane production from swine wastewater and to verify the suitability of effluent from anaerobic filters for the subsequent biological nitrogen and phosphorus removal. Stepwise increase in organic loading rates (OLRs) or decrease in hydraulic retention times (HRTs) with influent TCOD concentration of 14,000 mg/L were utilized at mesophilic temperature. The maximum methane productivity of 1.74 volume of $CH_4$ per volume of reactor per day (v/v-d) was achieved at an hydraulic retention time (HRT) of 0.5 day (OLR 28 g TVS/L-d). Based on the biogas production, the highest total volatile solids (TVS) removal efficiency of 63% was obtained at an HRT of 3 days (OLR 4.67 g TVS/L-d), however based on the result from the effluent total chemical oxygen demand (TCOD) analysis, the highest TCOD removal efficiency of 75% was achieved. The effluent alkalinity concentration over the range of 2,050~2,980 mg/L as $CaCO_3$ at all operational conditions, could compensate the alkalinity destruction caused by nitrification. The effluent from the anaerobic filter operated under the HRT of 2 days showed the COD/TKN ratio of 15~35 and COD/TP ratio of 38~56. Therefore effluent C/N/P ratio is able to satisfy the optimum COD/TKN ratio of greater than 8.0 and COD/TP ratio of 33 for the subsequent biological nutrient removal.

Development of Miniature Quad SAW Filter Bank based on PCB Substrate

  • Lee, Young-Jin;Kim, Chang-Il;Paik, Jong-Hoo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.1
    • /
    • pp.33-37
    • /
    • 2008
  • This paper describes the development of a new $5.0{\times}3.2mm$ SAW filter bank which is consist of 12 L, C matching components and 4 SAW bare chips on PCB substrate with CSP technology. We improved the manufacturing cost by removing the ceramic package through direct flip bonding of $LiTaO_3$ SAW bare chip on PCB board after mounting L, C passive element on PCB board. After that we realized the hermitic sealing by laminating the epoxy film. To confirm the confidentiality and durability of the above method, we have obtained the optimum flip bonding & film laminating condition, and figured out material property and structure to secure the durability & moisture proof of PCB board. The newly developed super mini $5.0{\times}3.2mm$ filter bank shows the superior features than those of existing products in confidence, electrical, mechanical characters.

Pilot Scale Test of Non-woven Fabric Filter Separation Activated Sludge Process for Practical Application on Domestic Wastewater Reclamation (파일럿 규모의 침지식 부직포 여재 활성슬러지 공정의 시스템 처리 특성에 관한 연구)

  • Lee, Sang-Woo;Choi, Chul-hoi;Park, Young-mi;Seo, Gyu-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.289-294
    • /
    • 2006
  • A pilot scale non-woven fabric filter separation activated sludge system was investigated for practical application on domestic wastewater reclamation and reuse. The system was operated in A/O (Anaerobic/Oxic) process with submerged filter module in the aerobic compartment. In the test of two types of filter materials ($70g/m^2$ and $35g/m^2$), the initial flux (0.42m/d) could be maintained for about three months by regular air backwashing of $70g/m^2$ filter at 0.3m water head. The removal efficiency of organic matter by the system was BOD 93.3%, CODcr 96.3%, SS 96.7%. The effluent quality was 7.8mg/L, 12mg/L and 5mg/L for BOD, CODcr and SS, respectively. The water quality was enough to meet a standard for domestic reuse without human contact. T-N removal efficiency was 49.9% at internal recycle rate 2Q and C/N ratio 3.3. The removal efficiency of T-P was 50% with average effluent concentration, 2.6mg/L.

AR modelling for a biomedical signal using Kalman filter (Kalman filter를 이용한 생체신호의 AR modelling)

  • Kim, D.K.;Park, H.J.;Chee, Y.J.;Park, K.S.;Lee, C.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.184-187
    • /
    • 1997
  • In terms of a system identification, we present a method for autoregressive(AR) modelling of variious biomedical signal. Model order is estimated fly low rank approximation and coefficients are determined by innovation processes of Kalman filter derivation. An application of the method is given for visual evoked potentials.

  • PDF

Effects of Membrane Filter and Sucrose Concentrations on the Growth of Balloon Flower (Platycodon grandiflorum A. DC.) Plantlets In Vitro (Membrane Filter와 Sucrose 농도가 도라지(Platycodon grandiflorum A. DC.) 기내 배양묘의 생장에 미치는 영향)

  • Choi, So-Ra;Kim, Myung-Jun;Eun, Jong-Seon;Ahn, Min-Sil;Lim, Hoi-Chun;Ryu, Jeong;You, Dong-Hyun
    • Journal of Plant Biotechnology
    • /
    • v.31 no.3
    • /
    • pp.209-217
    • /
    • 2004
  • The shoots of balloon flower (Platycodon grandiflorum A. DC.) in vitro germinated from seeds were cultured on MS basal medium containing 0.1 mg/L NAA under the various sucrose concentrations and with/without membrane filter (MF) on the lid of vessel. The growth responses were checked to obtain healthy plantlets. The $CO_2$ and $C_2$H$_4$ concentration in vessel without MF were higher than those with MF. The $CO_2$ concentration without MF was increased as days in culture went by whereas the $C_2$H$_4$ concentration was decreased. The plant growth with MF and high sucrose concentration was good. Fresh and dry weight of plantlets cultured in sucrose 4.5% with MF were higher than those in no sucrose without MF. Also the content of chlorophyll of plantlets cultured with MF was high and the content of sugar was shown a similar results and a remarkable difference between MF treatments, especially. Stomata cultured with MF was closer than that without MF and mesophyll of leaf were more developed with MF or in high sucrose concentration. When the plantlets were transplanted in the pot at 25$\pm$2$^{\circ}C$, 75% relative humidity and low PPFD (photosynthetic photon flux density), the percentage of survival after 13 days without MF was 0% but it was 100% with MF regardless of sucrose concentrations.