Abstract
Recently, power conversion equipment increased rapidly makes a lot of harmonics. Thus, it is growing that wrong operation and break down of sensitive devices. There are two kinds of causes of harmonics. One of them is lots of power conversion equipment as modem controller, inverter, converter and SWS(Switching Mode Power Supply). Another is nonlinear operating machines as transformer and motor. The more nonlinear loads like them grow, the more serious problems as harmonic current to source and low power factor because of increasing reactive power grow. It is installed for reactor and L-C Filter to decrease harmonic in general. This paper analysis and compares two of characteristics and harmonic from reactor and L-C Filter with operation of induction motor and power conversion equipment. In the result, L-C Filter more improves unbalance rate and THD than reactor.
Keywords
power conversion equipment; total harmonic distortion; induction motor;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김은식 외 1, 전력계통의 고조파 장해 분석, 한 국전기안전공사, pp. 91-146
2 강창원 외 4, '전력계통에서의 고조파 개선 사례 연구', 대한전기학회 2000년 하계학술대회 pp. 224-227, 2000
3 'IEEE Recomended Practice and Requirements for Harmonics Control in Electrical Power Systems', IEEE Std. 519-1992
4 'Nonlinear Load Mean Trouble', EC & M, Mar., pp. 83-90, 1988
5 J. Arrillaga., D. A. Bradley., 'Power System Harmonics', John Willy & Sons, 1985
6 Thomas Key, Jih-Sheng Lai, 'Analysis of Harmonic Mitigation Methode for Building Wiring system', IEEE Trans on Power System, Vol. 13, No. 3, Aug., pp. 890-897, 1998   DOI   ScienceOn
7 C. A. Quinn, N. Mohan, 'Active Filterring of Harmonic Currents in Three-phase, Four-Wire with Three- Phase and singie-phase Non-Linear Loads', in APEC, pp. 828-834, 1992
8 고원식 외 3, '직류전동기 가변속 구동장치의 고조파 저감을 위한 수동필터 제어시스템 연구', 한국전기안전공사, pp. 16-81
9 J. Reeve and P. C. S. Krishnayya, 'Unusual current harmonics arising from high voltage DC transmission', IEEE Trans. Power App. Syst., Vol. PAS-87, No. 3, Mar., pp. 884-892, 1968
10 Mark McGranaghan, 'Overview of the Guide for Applying Harmonic Limits on Power Systems', IEEE P519A Draft6, 1996
11 유상봉, 김세동, '전기설비의 고조파 장해 및 대책기술', 한국전력기술인협회지, 1996. 5
12 한국산업기술센터, 전기설비 운용 및 관리, pp. 149-133, 2003. 6
13 IEEE 141-1993, 'IEEE Recommended Practices and Requirements for Harmonic Control in Electric Power System'
14 관동전기보안협회, '고압 자가용 수용가의 고조 파 장해, 억제대책 사례 Q&A', 성안당, 2000
15 G. T. Heydt, Electric Power Quality, second Edition, Stars in a Circle Publications, Scottsdale(A/Z),u.s.a, 1994
16 G. C Jain, 'The Effect of Voltage Wave shape on the Performance of a Three Phase Induction Motor', IEEE Trans, Vol. PAS-84, 1964
17 W. S. Wood, F. P. Flynn, and A. Poray, 'Effects of Supply Voltage Waveform Distortion on Motor Performance', Int. Conf. on Sources and Effect of Power System Disturbances, London, England, April 22-24, 1974