• Title/Summary/Keyword: Korean Standards(KS)

Search Result 449, Processing Time 0.026 seconds

Watertightness and Durability Properties of Ultra Rapid Hardening Grout using Bottom-ash (잔골재 대체재로서 바텀애쉬를 이용한 초속경 그라우트재의 수밀성 및 내구특성)

  • Lee, Gun-Cheol;Oh, Dong-Uk;Cho, Byoung-Young;Kim, Young-Geun;Cho, Chung-Ki
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.102-109
    • /
    • 2011
  • In this study, in order to develop ultra rapid hardening mortar(URHM) for tunnel repairs using bottom ash of low recycle ratio and Admixture as Eco concept, watertightness and durability properties of URHM on temperature condition of construction field were performed. Test result, seepage quantity and water absorption coefficient regarding watertightness of URHM were as in the following : series II > series I. Seepage quantity for the standard condition were smaller than low temperatures. all specimens were satisfied below 20g as standards of seepage quantity on KS F 4042. Because of the decrease of unit cement content by to replacement of blast furnace slag, the neutrlization resistance for durability properties was reduced. The result of alkali resistance and acide resistance, compressive strengths for specimens soaked in calcium hydroxide solution of seriesI were lower than compressive strengths for specimens not soaked. On the other hand, the case of series II show that the deterioration of compressive strengths for specimens was not almost showed. Compressive strengths of specimens soaked were similar with specimens not soaked except series II-C in $5^{\circ}C$. Therefore, specimens using both blast furnace slag and bottom ash were good in alkali resistance and acide resistance.

  • PDF

A Study on Asphalt Paving Filler Development from Industrial By-products and its Characteristics in Construction Site (산업부산물을 활용한 아스팔트 포장용 채움재 개발 및 현장시공 성능평가 연구)

  • Cho, Do-Young;Park, Keun-Bae;Woo, Yang-Yi;Moon, Bo-Kyung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.227-234
    • /
    • 2016
  • In this study, asphalt paving filler, which satisfies the KS standards, were prepared from industrial by-products, such as fly ash generated from thermal power plants, cogeneration ash generated from cogeneration plants, and desulfurized gypsum generated from the flue-gas desulfurization process. The properties of the prepared mixed filler and the existing limestone filler were compared through laboratory tests for preparing asphalt mixture using each filler. In addition, asphalt pavement field tests were conducted using the limestone filler and mixed filler. The dynamic stability, Marshall stability, tensile strength ratio, saturation, porosity, and flow value of the asphalt mixtures used in the field test were evaluated, as was done in the laboratory test. The laboratory and field construction test results revealed outstanding tensile strength ratio, Marshall stability and dynamic stability when using the prepared filler than for the existing limestone filler. Through optimization of the mixing design, the possibility of developing fillers, which the characteristics of the existing limestone filler, was confirmed.

Analysis of Urban Park Nightscape based on the Design-Construction Process and Current Status - Focused on Yeouido Park - (도시공원 야간경관의 조성 과정과 실태 분석 - 여의도공원을 중심으로 -)

  • Kim, Hyun-Geun;Kim, Ah-Yeon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.2
    • /
    • pp.14-26
    • /
    • 2018
  • Light has been an essential part of human life. The advancement of technology has changed cities' nightscape and night activities in a drastic way. Lighting has influenced the identity of a city while promoting a variety of civic nighttime cultural pursuits, yet lighting design has not been considered adequately in the field of landscape architecture. This study aims to analyze the current status of lighting in urban parks through interviews with professionals, literature and regulation reviews, analysis of design documents and a field survey focused on Yeouido Park in Seoul. The findings and improvement directions are as follows. First, it is necessary to develop a specific lighting design method in order to avoid a marginalized, passive approach such as light fixture installation. Second, the existing standards of illuminance by KS A 3011 regulating only horizontal illuminance has turned out not to evaluate the current nightscape of urban parks properly. Therefore the criteria and guideline for analysis and design for nightscape should be articulated. Third, there are no design or management strategies to consider the changing landscape of urban parks, which is necessary due to the changing characteristics of park ecosystems. Lastly, detailed guidelines for distinguished spaces in urban parks should be studied and suggested.

Analysis of Fundamental Properties of Concrete Using Mix of Coarse Aggregate With Formation Causes (성인이 다른 굵은 골재를 혼합사용한 콘크리트의 기초적 특성 분석)

  • Noh, Sang-Kyun;Kim, Young-Hee;Kim, Jeong-Bin;Han, Cheon-Goo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.1
    • /
    • pp.15-21
    • /
    • 2015
  • Recently, attempts of replacing some of natural aggregate with mix of low quality aggregate are carried out for stable supply of aggregate. However, low quality aggregate such as recycled aggregate produced during the disposal process of construction wastes and by-product aggregate produced by industrial activities has problem of failing to comply to KS Standards. Therefore, we have compared fundamental properties of concrete by using granite crushed aggregate, recycled aggregate, blast furnace and electric arc furnace slag aggregate for effective utilization of lacking aggregate resources. As the result, slump in case of mixed use of aggregate was increased 0~10% compared to single use. Therefore, it is judged to be economically advantageous as it can expect effects in unit quantity or reduction of SP agent. Compressive strength in case of mixed use of aggregate was increased 0~10% compared to single use as it filled internal crevice of concrete with continuous particle size distribution. Accordingly, if we utilize by satisfying standard particle scope through mix of aggregate with different cause of formation in proper ratio, it was possible to confirm utility of mixed aggregate with demonstration of effects of increases of fluidity and compressive strength of concrete.

A Study on Hazards Assessment of Electrostatic Firing Explosion of Working Wears at LPG Stations in Korea (한국의 LPG 충전소에 있어서 작업복의 정전기에 의한 화재 및 폭발 위험성에 관한 연구)

  • Cho young doo;Koo Ja Hyeuk;Choi Kwang Seo;Seo Dae Won;Joung Jae Hee;Takeuchi Manabu
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.20-24
    • /
    • 2000
  • The electrostatic safety consciousness of safety manager were investigated through questionnaires sent to liquid petroleum gas stations in Korea. In addition, hazards of fire and explosion due to electrostatic on synthetic-polymer-wears and cotton-wears were estimated experimentally. The results of questionnaires indicate most workers wear their working clothes indiscreetly owing to lack of knowledge of preventing electrostatic hazards. The amounts of electrostatic charge generated in synthetic-polymer-wears were 1.79, 1.44 and 1.02 $\mu$C in winter, spring and autumn and summer, respectively. All these values exceed the limit of working wears of 0.60$\mu$C requested by Korea Standard(KS K-7807) for preventing electrostatic hazards, which means hazards may occur. While, the charge in cotton-wears were in the range of 0.42 to 0.52$\mu$C, which suggests that the cotton-wears investigated in this study have no problem of hazards. Therefore workers, visual and experiential education are necessary for elevating the standard of on electrostatics. It is also necessary to establish standards of wearing for preventing electrostatic hazards.

  • PDF

Basic Study on Development of Eco-Friendly Vegetation-Block (친환경 식생블록 개발을 위한 기초연구)

  • Heo, Yol;Oh, Sewook;Bang, Seongtaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.4
    • /
    • pp.61-67
    • /
    • 2014
  • With a view to resolving environmental problems of hazardous cement, this study seeks to identify the unconfined compressive strength and bending strength of the vegetation block designed herein by utilizing high-strength natural soil stabilizer instead of cement. Soil stabilizer is mainly made of mixture of short fiber extracted from natural fiber and lime, etc. Soil stabilizer reinforces the shearing strength of soil to improve block supportive power and durability while preventing flood and frost damages. For the unconfined compressive strength test, test pieces were prepared by mixing soil stabilizer and weathered soil in different ratios of 6 %, 12 % and 18 %. Experiments were carried out according to curing periods of 5th, 7th, 14th and 28th of the day. For bending strength test, blocks were made in the same mixture ratios as for the unconfined compressive test and tested for each stage. Also, to evaluate for the field applicability, proposed optimum water content considering the characteristics of the soil stabilizer. Permeability test result for the vegetation block, satisfied by the KS F 4419 quality standards.

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.

A Study on the Applicability of Water Footprint Methodology in Korea by Analyzing Domestic Water Resources Statistics (국내 물 자원 통계자료 분석을 통한 물발자국 방법론 국내 적용 가능성 확인 연구)

  • Kim, Sun Uk;Jo, Seo Weon;Ahn, Jae Hyun;Lee, Han Woong;Yeon, Sung Mo
    • Clean Technology
    • /
    • v.24 no.2
    • /
    • pp.146-153
    • /
    • 2018
  • The water footprint is an important component of the Single Market for Green Product initiative based on the EU's Roadmap to a Resource Efficient Europe. In July 2014, the EU has established the International Standard for Water Footprint (ISO 14046) and Korea has complied with the Korean Industrial Standard (KS I ISO 14046) in April 2015. If a certification system based on the international standard (ISO 14046) is introduced, developing countries such as India and Vietnam, which are not equipped with bases, can become a trade barriers in exporting, so Korea should establish a strategy to reverse them. On the other hand, water footprints are designed to take into account local environmental impacts when compared to similar footprints (eg, carbon footprint) using LCA, so that products manufactured and manufactured in Korea will have an impact on domestic waters Should be considered. Therefore, the method of the water footprint should conform to the standard for compatibility with other countries. In order to consider the domestic water condition, it is necessary to identify suitable indicator or factor for estimating water footprint on Korea. For this purpose, this study analyzed the water footprint estimation study conducted at domestic and foreign based on international standards and through the analysis of statistical data related to domestic water resources, we confirmed the applicability of the water footprint methodology in Korea.

The Mechanical Properties of SMA Concrete Mixture Using Steel Slag Aggregate (제철 슬래그 골재를 이용한 SMA 혼합물의 역학적 특성)

  • Kim, Hyeok-Jung;Na, Il-Ho
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.1
    • /
    • pp.109-116
    • /
    • 2021
  • In order to replace mineral aggregate used as road pavement materials with steel slag aggregate, this present study evaluated mechanical properties of SMA Concrete mixtures using steel slag aggregate as oxidized slag from electric furnace in iron works. The variables of this experiment are the aggregate type of mineral and steel slag and the sieve sized of 10mm and 13mm. The physical properties inclu ding the specific gravity and absorption rate etc. of the slag aggregate mixtu res satisfied the KS standard as asphalt mixtu re. As a resu lt of evalu ating the mechanical properties of the asphalt mixtures, the optimum asphalt content of the slag aggregate mixtures were lower than that of the mineral aggregate mixtures, but other quality standards were all satisfied. In the deformation strength evaluation, the slag aggregate mixtures were measu red slightly higher than that of the mineral aggregate mixtu res, and the dynamic stability test satisfied the 2,000pass/mm standard value in all specimens. And, the moduli of resilient of the slag aggregate mixtures showed an improved value compared with the mineral aggregate mixtures. Therefore, as the resilient rate of the slag aggregate mixtures improved, it is speculated that there will be an effect of improving public performance according to the repeated traffic load of the vehicle.

A Study on the Current Status and Diagnosis of Risk Management: Focusing on University Archives (기록관의 위험관리 현황 진단 연구: 대학기록관을 중심으로)

  • Go, Eunbit;Kim, Hyunjung
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.22 no.1
    • /
    • pp.109-132
    • /
    • 2022
  • The purpose of this study is to improve the level of records management by enhancing the risk management in university archives. Through surveys and post-interviews, the current status of risk management in university archives was investigated, the results of the investigation were analyzed to identify problems and limitations in risk management in university archives, and the following suggestions for improvements were made. First, the legal effects of risk management should be strengthened in the Public Records Management Act, and matters related to risk management should be stipulated. Second, the National Archives of Korea should actively intervene to identify problems in risk management in university archives and provide appropriate support for problem-solving. Third, the identity of university archives as independent organizations should be secured for the implementation of professional and active records management tasks. Fourth, standards and manuals reflecting risk management practices for university archives should be prepared. Fifth, a sufficient budget must be secured to meet all necessary requirements for risk management. Lastly, cooperation in the performance of records management and risk management tasks should be achieved by raising awareness of university archives and their records management tasks among the heads of the institutions and members of the organizations.