• Title/Summary/Keyword: Joint Energy

Search Result 953, Processing Time 0.025 seconds

Physical and Mechanical Properties on Ipseok-dae Columnar Joints of Mt. Mudeung National Park (무등산국립공원 입석대 주상절리대에 대한 물리역학적 특성)

  • Ko, Chin-Surk;Kim, Maruchan;Noh, Jeongdu;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.26 no.3
    • /
    • pp.383-392
    • /
    • 2016
  • This study is to evaluate the physical and mechanical properties on the Ipseok-dae columnar joints of Mt. Mudeung National Park. For these purposes, physical and mechanical properties as well as discontinuity property on the Mudeungsan tuff, measurement of vibration and local meteorology around columnar joints, and ground deformation by self-weight of columnar joints were examined. For the physical and mechanical properties, average values were respectively 0.65% for porosity, 2.69 for specific gravity, 2.68 g/cm3 for density, and 2411 m/s for primary velocity, 323 MPa for uniaxial compressive strength, 81 GPa Young's modulus, and 0.25 for Poisson's ratio. For the joint shear test, average values were respectively 3.15 GPa/m for normal stiffness, 0.38 GPa/m for shear stiffness, 0.50 MPa for cohesion, and 35° for internal friction angle. The JRC standard and JRC chart was in the range of 4~6, and 1~1.5, respectively. The rebound value Q of silver schmidt hammer was 57 (≒ 90 MPa). It corresponds 20% of the uniaxial compressive strength of intact rock. The maximum vibration value around the Ipseok=dae columnar joints was in the range of 0.57 PPV (mm/s)~2.35 PPV (mm/s). The local meteorology of surface temperature, air temperature, humidity, and wind on and around columnar joints appeared to have been greatly influenced the weather on the day of measurement. For the numerical analysis of ground deformation due to its self-weight of the Ipseok-dae columnar joints, the maximum displacement of the right ground shows when the ground distance is approximately 2 m, while drastically decreased by 2~4 m, thereafter was insignificant. The maximum displacement of the middle ground shows when the ground distance is approximately 0~2 m, while drastically decreased by 3~10 m, thereafter was insignificant. The maximum displacement of the left ground shows when the ground distance is approximately 5~6 m, while drastically decreased by 6~10 m, thereafter was insignificant.

The usefulness of CT for the diagnosis and the fragment fixation of anteroinferior tibiofibular ligament avulsion fracture in ankle fracture (족관절 골절에서 전하 경비 인대 견열 골절의 진단과 골편 고정술을 위한 전산화 단층 촬영의 유용성)

  • Na, Hwa-Yeop;Cho, Kook-Hee;Jung, Yu-Hun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.78-85
    • /
    • 2011
  • Purpose: To evaluate the usefulness of computerized tomography (CT) for the diagnosis and the fragment fixation of anteroinferior tibiofibular ligament avulsion fracture in ankle fracture. Materials and Methods: We retrospectively studied 108 patients with an ankle fracture who had been checked with plain radiographs and CT from July 2006 to July 2010. They were divided into two groups; patients with (19 patients) and without (89 patients) an avulsion fracture of anteroinferior tibiofibular ligament. The two groups were evaluated with Lauge-Hansen classification, the energy of trauma, and the radiologic indices for syndesmotic injury, and were compared each other. Average follow up periods of two groups were 25 and 23 months each. Those who were unstable at stress test during surgery were divided into fragment fixation of anteroinferior tibiofibular ligament avulsion fracture group (8 patients) and transfixation one (11 patients) according to treatment method. Clinical and radiological results at last follow up were also compared. Results: Fourteen avulsion fractures of anteroinferior tibiofibular ligament were diagnosed by CT only. Incidences of pronation-external rotation injury, high energy trauma, positive radiologic indices for syndesmotic injury were significantly higher in patients with an avulsion fracture of anteroinferior tibiofibular ligament than those without it. Clinical and radiological results were satisfactory in both groups at last follow up, and were not significantly different between them. Conclusion: In patients who have an ankle fracture by pronation-external rotation injury, high energy trauma, or with positive radiologic indices for syndesmotic injury, CT is useful for diagnosis of an avulsion fracture of anteroinferior tibiofibular ligament. Fragment fixation of anteroinferior tibiofibular ligament avulsion fracture is a useful treatment option for syndesmotic injury.

  • PDF

The Study on the Long-term Reliability Characteristics of Ribbon Joint: Solar Cell Ribbon Thickness and Solder Compositions (태양전지 Ribbon 두께와 조성에 따른 Ribbon접합부의 장기 신뢰성 특성에 관한 연구)

  • Jeon, Yu-Jae;Kang, Min-Soo;So, Kyung-Jun;Lee, Jae-June;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.88-94
    • /
    • 2014
  • In this paper, Thermal Shock tests were performed varying the composition of the solder and ribbon thickness (A-type:0.2mm/60Sn40Pb, B-type:0.25mm/60Sn40Pb, C-type:0.2 /62Sn36Ag2Pb, D-type:0.25mm/62Sn36Ag2Pb) for evaluating the long-term reliability about Ribbon junction of Silicon solar cells. Thermal Shock test condition was performed during the 600cycles having $-40^{\circ}C{\sim}85^{\circ}C$ temperature range each 15 minutes; One cycle time was 30min. As a result, the initial efficiency of the A-type, B-type, and C, D-type were showed 15.0%, 15.4% and 15.8% respectively. After thermal shock test, the efficiency decreasing-rate of each type were as follow that A-type was 13.8%, B-Type was 15.4%. C-Type and D-Type was 15.3% and 16.2%, respectively. Also, degradation of surface changes and I-V characteristic curves were showed that the series resistance of the A, C-type was increased. Also, current lowering starting point of C-type shown 0.05volt[v] earlier than that of A-type. And B, D-type shown characteristics of composite lowering efficiency such as increase of series resistance, decrease of parallel resistance and cell damage. Therefore Initial solderability and efficiency of specimens using the solder with SnAgPb were superior. But, It has inferior the long-term reliability. The test was confirmed that as the ribbon thickness increases, long-term reliability of solar cell will decrease.

Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy (골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구)

  • Kim Woo Chul;Park Won;Kim Heon Jong;Park Seong Young;Cho Young Kap;Loh John J;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.497-504
    • /
    • 1998
  • Purpose : To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film Materials and Methods : From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 Mu/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum. iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated - very clear (1), clear (2), visible (3), not clear (4), not visible (5). Results : Using an video camera based EPID system. there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image qualify after window level adjustment. Conclusion : The quality of image acquired using an electronic portal imaging device was comparable to that of the port film. When we used the enhance mode or window level adjustment. the image quality of the EPID was superior to that of the port film. EPID may replace the port film.

  • PDF

Tritium Fuel Cycle of the International Thermonuclear Experimental Reactor (국제핵융합실험로 삼중수소 연료주기)

  • Song, Kyu-Min;Sohn, Soon Hwan;Chung, Hongsuk;Yun, Sei-Hun;Jung, Ki Jung
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.595-603
    • /
    • 2012
  • International Thermonuclear Experimental Reactor (ITER) will be constructed in 2019 according to the JIA (Joint Implementation Agreement) of 7 countries. The ITER fusion fuel cycle consists of fusion vacuum vessel, tritium plant and fuelling system. The tritium plant provides the functions of storage, delivery, separation, removal and recovery of the deuterium and tritium used as fusion fuels for the ITER. The tritium plant systems supply deuterium and tritium from external sources and treat all tritiated fluids from ITER operation through Storage and Delivery System (SDS), Tokamak Exhaust Processing (TEP), Isotope Separation System (ISS), Water Detritiation System & Atmosphere Detritiation System (WDS & ADS) and Analysis System (ANS). In this paper, the functions and design requirements of the major systems in the tritium plant and the status of R&D are described. Korean party is developing the SDS for ITER tritium plant and partially attaining the WDS technology through the construction and operation experience of the Wolsong Tritium Removal Facility (WTRF). Now it is expected that researchers in other fields such as chemical engineering take part in the development of upcoming technologies for ISS and TEP.

Fully automatic Segmentation of Knee Cartilage on 3D MR images based on Knowledge of Shape and Intensity per Patch (3차원 자기공명영상에서 패치 단위 형상 및 밝기 정보에 기반한 연골 자동 영역화 기법)

  • Park, Sang-Hyun;Lee, Soo-Chan;Shim, Hack-Joon;Yun, Il-Dong;Lee, Sang-Uk
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.6
    • /
    • pp.75-81
    • /
    • 2010
  • The segmentation of cartilage is crucial for the diagnose and treatment of osteoarthritis (OA), and has mostly been done manually by an expert, requiring a considerable amount of time and effort due to the thin shape and vague boundaries of the cartilage in MR (magnetic resonance) images. In this paper, we propose a fully automatic method to segment cartilage in a knee joint on MR images. The proposed method is based on a small number of manually segmented images as the training set and comprised of an initial per patch segmentation process and a global refinement process on the cumulative per patch results. Each patch for per patch segmentation is positioned by classifying the bone-cartilage interface on the pre-segmented bone surface. Next, the shape and intensity priors are constructed for each patch based on information extracted from reference patches in the training set. The ratio of influence between the shape and intensity priors is adaptively determined per patch. Each patch is segmented by graph cuts, where energy is defined based on constructed priors. Finally, global refinement is conducted on the global cartilage using the results of per patch segmentation as the shape prior. Experimental evaluation shows that the proposed framework provide accurate and clinically useful segmentation results.

Efficacy of Temporal Fixation Using Threaded Trans-Calcaneal Pin in Patients with Ankle Fracture-Dislocation or Tibia Pilon Fractures (발목 골절 및 탈구 혹은 경골 천정 골절 환자들의 수술에 있어 경종골핀을 이용한 발목 외고정 장치를 적용했을 때의 임상적 효용성)

  • Park, Dae-Hyun;Gwak, Heui-Chul;Kim, Jung-Han;Lee, Chang-Rak;Kwon, Yong-Uk;Choo, Hye-Jung;Park, Chul-Soon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.2
    • /
    • pp.81-86
    • /
    • 2020
  • Purpose: Ankle fractures with dislocations and pilon fractures at the distal tibia are usually associated with soft tissue damage caused by high-energy damage. Recently, a two-stage operation to perform internal fixation after the application of external fixation devices for stabilizing soft tissues has been accepted as the treatment of choice. This paper reports the clinical result of these injuries treated with threaded trans-calcaneal pin external fixation devices. Materials and Methods: Thirty-three patients diagnosed with ankle fractures with dislocations or tibial pilon fractures without open wounds. They underwent surgical treatment with threaded trans-calcaneal pin external fixation from January 2008 to February were enrolled in this study. This study evaluated the visual analogue scale (VAS), foot function index (FFI), and Olerud & Molander score as well as whether complications occurred. Results: The average VAS showed a meaningful decrease (p<0.001) from 7.4 before surgery to 2.6 after application of the external fixation device, and 1.4 at 12 months after surgery. The FFI also decreased significantly from 84.3 preoperatively to 20.3 at 12 months postoperatively (p<0.001). The Olerud & Molander score averaged 71.4 points, showing good clinical results. Complete bone union was observed in all patients. One patient each underwent debridement due to wound necrosis and infection in the pin insertion site. At the final follow-up, seven patients had posttraumatic ankle joint arthritis, according to a radiological examination. Conclusion: Manual reduction and external fixation using a threaded trans-calcaneal pin is a suitable surgical technique that is easy to perform and shows good clinical outcomes in stabilizing soft tissue damage in fractures and dislocations of ankle fracture or tibia pilon fractures in foot and ankle injury.

The Health and Dietary management of Impaired elderly by ADL in Gyeonggi, Korea (ADL에 의한 도움필요 노인의 건강과 식생활관리 -경기지역 농촌노인을 중심으로-)

  • Rhie Seung-Gyo;Choi Mi-Yong;Won Hyang-Rye
    • The Korean Journal of Community Living Science
    • /
    • v.17 no.3
    • /
    • pp.159-174
    • /
    • 2006
  • The purpose of this study is to provide information searching for health promotion, nutrition improvement, and health care of the impaired elderly by ADL(Activity of Daily Living) and IADL(Instrumental Activity of Daily Living). The subjects were divided into the Assistant Needed Group and No Assistant Needed Group for living in line with the responses of ADL(10 items like dressing, washing, move etc.) and IADL(10 items like housekeeping, using transportation, shopping, Phone call etc.). Survey was made for health behavior, health risk habit, dietary management status and diet intake by 24 hr-recall and questionnaire method. 242 subjects were collected in 12 cities or Gun districts in Gyeonggi Province, S. Korea. Survey was carried out by regional home extension workers using interview method. Statistical analyses were made using SAS (Version 8.1). Chi-Square Tests and General Linear Models. The subjects of impaired ADL elderly was 26.5% and it composed 30% of the total male and 22.2% of the total female. The demographic status of the impaired ADL elderly showed no difference from that of the normal elders, elementary school educated (73.4%), with spouse (43.8%) or with adult children(37.5%), using monthly living cost of 500-1,000 thousand won(35.9%). Mean age was 74.05 years compared to 72.25 years of normal elders. However, there was no significant difference from the normal and impaired ADL group, regular exercise(60.0%), with walking (90.0%), no-smoke(54.7%) and no-drink(48.4%). Kind of disease was not different from the one in impaired and normal group, with cardiovascular disease(32.3%), with diabetes mellitus(8.1%), joint lumbago neuralgia(32.3%) and osteoporosis(9.7%). Gastrointestinal complaints of the impaired ADL group were nausea(57.8%), chronic indigestion (23.4%), constipation (14,0%) and vomiting(3.7%). Sleeping time required for the impaired was longer than that for the normal group by 10hours(4.7%) or 8-10hours(20.3%), which consisted 1.7% and 16.6% respectively. Nutrient intake of the impaired ADL group was low compared to normal range elders: Energy(1260kca1), Protein(52.75g). There was gender difference in nutrient intake; the male impaired group showed no significant difference from the normal group but it was significantly lower in female impaired group. These results suggest that low quality of life and low economic status of the impaired ADL elderly require congregate meal in village hall to cover the lack of side dishe variety. And nutrition education program including community assistance would be required for the impaired ADL elderly together with the sufficient food and exercise practice. By operating nutrition education program, the impaired ADL elderly would maintain more enhanced quality of life and ameliorate the ADL capability.

  • PDF

Study of a Mixed Finite Element Model for the Analysis of a Geometrically Nonlinear Plate (기하학적 비선형 판재 해석을 위한 혼합형 FE Model 연구)

  • Kim, Woo-Ram;Choi, Youn-Dae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1427-1435
    • /
    • 2010
  • A mixed finite element model was developed using the classical plate theory to analyze the nonlinear bending of a plate. The appropriate weight functions for the constraints integrated over the domain were determined by the Lagrange multiplier method by using the principle of minimum virtual energy; which provides the constitutive relations between force-like variables and strains. All of detail terms of element wise coefficient matrices and associate tangent matrices to be used in the Newton iterative method are presented. Then, the linear solutions of the current model and those of the traditional displacement model under the SS (simple support) boundary conditions were compared with the existing analytical solution. The post-processed images of the nonlinear results of the force-like variables are presented to show the continuity of the solutions at the joint of the element boundaries. Finally, the converged nonlinear finite element solutions of the current model are compared with those of existing traditional displacement model.

Estimation of Human Lower-Extremity Muscle Force Under Uncertainty While Rising from a Chair (의자에서 일어서는 동작 시 불확실성을 고려한 인체 하지부 근력 해석)

  • Jo, Young Nam;Kang, Moon Jeong;Chae, Je Wook;Yoo, Hong Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1147-1155
    • /
    • 2014
  • Biomechanical models are often used to predict muscle and joint forces in the human body. For estimation of muscle forces, the body and muscle properties have to be known. However, these properties are difficult to measure and differ from person to person. Therefore, it is necessary to predict the change in muscle forces depending on the body and muscle properties. The objective of the present study is to develop a numerical procedure for estimating the muscle forces in the human lower extremity under uncertainty of body and muscle properties during rising motion from a seated position. The human lower extremity is idealized as a multibody system in which eight Hill-type muscle force models are employed. Each model has four degrees of freedom and is constrained in the sagittal plane. The eight muscle forces are determined by minimizing the metabolic energy consumption during the rising motion. Uncertainty analysis is performed using a first-order reliability method. The one-standard-deviation range of agonistic muscle forces is calculated to be about 150-300 N.