Browse > Article
http://dx.doi.org/10.14193/jkfas.2020.24.2.81

Efficacy of Temporal Fixation Using Threaded Trans-Calcaneal Pin in Patients with Ankle Fracture-Dislocation or Tibia Pilon Fractures  

Park, Dae-Hyun (Department of Orthopaedic Surgery, Inje University Busan Paik Hospital)
Gwak, Heui-Chul (Department of Orthopaedic Surgery, Inje University Busan Paik Hospital)
Kim, Jung-Han (Department of Orthopaedic Surgery, Inje University Busan Paik Hospital)
Lee, Chang-Rak (Department of Orthopaedic Surgery, Inje University Busan Paik Hospital)
Kwon, Yong-Uk (Department of Orthopaedic Surgery, Inje University Busan Paik Hospital)
Choo, Hye-Jung (Department of Radiology, Inje University Busan Paik Hospital)
Park, Chul-Soon (Department of Orthopaedic Surgery, Inje University Busan Paik Hospital)
Publication Information
Journal of Korean Foot and Ankle Society / v.24, no.2, 2020 , pp. 81-86 More about this Journal
Abstract
Purpose: Ankle fractures with dislocations and pilon fractures at the distal tibia are usually associated with soft tissue damage caused by high-energy damage. Recently, a two-stage operation to perform internal fixation after the application of external fixation devices for stabilizing soft tissues has been accepted as the treatment of choice. This paper reports the clinical result of these injuries treated with threaded trans-calcaneal pin external fixation devices. Materials and Methods: Thirty-three patients diagnosed with ankle fractures with dislocations or tibial pilon fractures without open wounds. They underwent surgical treatment with threaded trans-calcaneal pin external fixation from January 2008 to February were enrolled in this study. This study evaluated the visual analogue scale (VAS), foot function index (FFI), and Olerud & Molander score as well as whether complications occurred. Results: The average VAS showed a meaningful decrease (p<0.001) from 7.4 before surgery to 2.6 after application of the external fixation device, and 1.4 at 12 months after surgery. The FFI also decreased significantly from 84.3 preoperatively to 20.3 at 12 months postoperatively (p<0.001). The Olerud & Molander score averaged 71.4 points, showing good clinical results. Complete bone union was observed in all patients. One patient each underwent debridement due to wound necrosis and infection in the pin insertion site. At the final follow-up, seven patients had posttraumatic ankle joint arthritis, according to a radiological examination. Conclusion: Manual reduction and external fixation using a threaded trans-calcaneal pin is a suitable surgical technique that is easy to perform and shows good clinical outcomes in stabilizing soft tissue damage in fractures and dislocations of ankle fracture or tibia pilon fractures in foot and ankle injury.
Keywords
External fixation; Mono fixator; Ankle injury; Calcaneal pin;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Davidovitch RI, Elkhechen RJ, Romo S, Walsh M, Egol KA. Open reduction with internal fixation versus limited internal fixation and external fixation for high grade pilon fractures (OTA type 43C). Foot Ankle Int. 2011;32:955-61. doi: 10.3113/FAI.2011.0955.   DOI
2 Babis GC, Vayanos ED, Papaioannou N, Pantazopoulos T. Results of surgical treatment of tibial plafond fractures. Clin Orthop Relat Res. 1997;(341):99-105.
3 Pollak AN, McCarthy ML, Bess RS, Agel J, Swiontkowski MF. Outcomes after treatment of high-energy tibial plafond fractures. J Bone Joint Surg Am. 2003;85:1893-900. doi: 10.2106/00004623-200310000-00005.   DOI
4 Pugh KJ, Wolinsky PR, McAndrew MP, Johnson KD. Tibial pilon fractures: a comparison of treatment methods. J Trauma. 1999;47:937-41. doi: 10.1097/00005373-199911000-00022.   DOI
5 Wang C, Li Y, Huang L, Wang M. Comparison of two-staged ORIF and limited internal fixation with external fixator for closed tibial plafond fractures. Arch Orthop Trauma Surg. 2010;130:1289-97. doi: 10.1007/s00402-010-1075-6.   DOI
6 Koulouvaris P, Stafylas K, Mitsionis G, Vekris M, Mavrodontidis A, Xenakis T. Long-term results of various therapy concepts in severe pilon fractures. Arch Orthop Trauma Surg. 2007;127:313-20. doi: 10.1007/s00402-007-0306-y.   DOI
7 Han SB, Shin YS. The treatment principles and latest knowledge of external fixator in the treatment of fractures. J Korean Fract Soc. 2013;26:156-63. doi: 10.12671/jkfs.2013.26.2.156.   DOI
8 Marsh JL, Bonar S, Nepola JV, Decoster TA, Hurwitz SR. Use of an articulated external fixator for fractures of the tibial plafond. J Bone Joint Surg Am. 1995;77:1498-509. doi: 10.2106/00004623-199510000-00004.   DOI
9 Rammelt S, Endres T, Grass R, Zwipp H. The role of external fixation in acute ankle trauma. Foot Ankle Clin. 2004;9:455-74, vii-viii. doi: 10.1016/j.fcl.2004.05.001.   DOI