Assessment of Smoke Risk of Combustible Materials in Fire (화재 시 가연성 물질의 연기 위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.31 no.3
    • /
    • pp.277-283
    • /
    • 2020
  • The smoke hazard assessment of building materials focusing on smoke performance index-II (SPI-II) and smoke growth index-II (SGI-II) was investigated. The test species used were Japanese cedar, spruce, lauan, and red pine. The smoke characteristics of wood specimen were investigated using a cone calorimeter (ISO 5660-1). SPI-II was measured after the combustion reaction increased by 1.31~2.15 times based on red pine. The fire risk by SPI-II increased in the order of spruce, lauan, Japanese ceda, and red pine. SGI-II increased by 1.18~2.55 times compared to that of Japnese ceda. The fire risk caused by SGI-II increased in the order of Japanese ceda, spruce, lauan, and red pine. COmean concentrations were ranged from 58 to 133 ppm, which was higher than permissible exposure limits of the occupational safety and health administration (OSHA), 50 ppm. Therefore, woods such as red pine containing various volatile organic substances, were considered to be highly smoke hazardous due to low SPI-II and high SGI-II.

A Study on the Japanese Maritime Oil Spillage Management System and Activities (일본의 해양유탁 방제체제와 방제활동에 관한 연구)

  • Choi, Young-Ho
    • Journal of Navigation and Port Research
    • /
    • v.26 no.4
    • /
    • pp.407-417
    • /
    • 2002
  • Japanese oil companies have begun to set up a mutual support system to prepare for any large scale oil spillages due to the huge increase in size of tankers since 1973. In 1990, the Petroleum Association of Japan established the Oil Spill Response Department and has been conducting researches on management of oil spill combatting materials and the effective prevention of maritime oil disasters. Japan Coast Guard, in accordance with the regulations of the OPRC in 1995, formulated the national contingency plan and built a mutual-contact network among the related government institutions. Its Guard & Rescue Department. Disaster Prevention Section has been working for the maintenance of oil spill combatting materials and coordinating related work with private organizations. The Japanese government has been strengthening the maritime oil spillage management system since the Nakhodka wreck incident in 1997.

Dissemination of Nursing Science and Nursing Training Policy during the Japanese Colonial Period (일제강점기 간호학의 보급과 간호사 양성 정책)

  • Jung, Eun-Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.7
    • /
    • pp.329-336
    • /
    • 2021
  • This study attempted to present the direction that nursing should have for the future nursing development by looking at the process of trying to protect the subjectivity of nursing in various events during the Japanese colonial period. In the early days of modern nursing, from 1910 to 1919, nursing education institutions were expanded and nursing-related systems were created. From 1920 to 1937, as a development of modern nursing, not only expanded the field of nursing, but also revised nursing-related laws and organized two nursing associations. From 1939 to 1945, the stagnation period of modern nursing, amidst the social disaster of war, a training policy for mobilizing war personnel was unfolded, and another change was experienced. In order to expand the field of nursing and continue to develop it, continuous interest and research on the role and spread of nursing that change in various social events from the past to the present are needed.

Suggestions to Improve the Effectiveness of National Radiological Emergency Response System (국내 방사능재난대응체계 실효성 제고를 위한 제언)

  • Moon, Joo Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.195-206
    • /
    • 2020
  • Although the national radiological emergency response system has been improved by incorporating lessons from the Fukushima nuclear power plant accident and recent domestic natural disasters, it has not fully incorporated these lessons. In addition, it cannot deal with a variety of aftermath of the radiological disaster. Even for the same disaster, the national emergency response system should comply with multiple domestic laws in our country. Furthermore, there are a few discrepancies between the articles of the domestic laws that the national radiological emergency response system should address. Therefore, this study investigates the characteristics of radiological disasters, examines articles on the domestic laws related to the national radiological emergency response system, and analyses the Japanese government's responses to the Fukushima nuclear power plant accident. Based on the results of the review, suggestions for the improvement of the national radiological emergency response system in terms of response organization and framework have been proposed in this study.

Allometric Equations of Crown Fuel Biomass and Analysis of Crown Bulk Density for Pinus densiflora (소나무 수관 부위별 연료량 추정식 개발 및 수관연료밀도 분석)

  • Lee, Byung-Doo;Won, Myoung-Soo;Kim, Seon-Young;Yoon, Suk-Hee;Lee, Myung-Bo
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.3
    • /
    • pp.391-396
    • /
    • 2010
  • To analyze the characteristics of canopy fuel in Pinus densiflora stand, which is essential to assess the crown fire hazard, allometric equations for estimation of crown fuel biomass were developed by subjectively categorized crown fuel component and crown bulk density was analyzed by available fuel component categories. Ten trees were destructively sampled at Pinus densiflora stand in Mt. Palgong in Daegu and their crown fuels were weighed separately for each fuel category by size classes and by living and dead. Regression equations that estimate crown fuel load by diameter at breast height(D) or additional total height(H) were derived. The adjusted coefficient of determination values were the highest (${R^2}_{adj}$=0.835-0.996) and standard error of estimate were the lowest (SEE=0.074-0.638) in the allometric equation lnWt=${\alpha}+{\beta}lnD+{\gamma}lnH$ in average. However, in needles and small branches categories, the differences in ${R^2}_{adj}$ and SEE between equations were not significant. Crown bulk density (CBD), which was calculated by crown fuel load divided by crown volume, was 0.067 kg/$m^3$ in average when only needles were considered as available crown fuel and 0.097 kg/$m^3$ when needles and branches (0-0.5 cm diameter) were considered. The increments of CBD of needles and small branches were little even when diameter at breast height increased.

A Study on the Classification Scheme of Technologies for Disaster Prevention of Railroad Structures (재해에 대한 철도시설물 방재기술 체계에 관한 연구)

  • Park, Young-Kon;Yoon, Hee-Taek;Shin, Min-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2902-2909
    • /
    • 2011
  • Regional torrential rains in summer this year due to abnormal climate changes compared to last year, have been frequent. Since Typhoon Rusa and Typhoon Maemi resulted in major damage to railroad facilities in 2002 and 2003 consecutively, problems with abnormal climate changes became a global problem including railroad and floods and droughts around the globe, heavy snow and winter warming have been repeated until now. Serious problem of radiation leakage in Fukushima nuclear power plant by the Tsunami due to 9.0-scale earthquake, this year in March, in northeastern Japan happened, and has given an impact on the life of Japanese citizens and industries and has also influenced on Korean. This shows how important to secure and to protect major national facilities including railroad structures to natural disasters such as earthquake. Therefore, we will briefly discuss about technologies for securing and protecting railroad structures to earthquakes, floods and other natural disasters.

  • PDF

Recent Improvement of Coastal Wave-Tide Observation and Textbooks Publication

  • Toshihiko Nagai;Chuji Yamamoto;Masao Mitsui;Yasuo Shimizu;Ahn, Hee-Do;Shin, Seung-Ho
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.233-239
    • /
    • 2003
  • Coastal wave and tide information is very important in various occasions for port and harbor engineers, in the stages such as port and harbor planning, maritime structure design, maritime construction management, and coastal disaster study This paper introduces recent improvement of Japanese coastal wave-tide observation and information system named as NOWPHAS (Nationwide Ocean Wave information network for Ports and HArbourS). Development and improvement of the NOWPHAS has been achieved during recent decade in the following points of view (Nagai,2002a,2002b). (omitted)

  • PDF

A Basic Study on the Evaluation Factor for Deteriorated Level of Rural House (농촌주택의 노후도 평가요소 도출을 위한 기초연구)

  • Park, Gil-Beom;Park, Jun-Mo;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.107-108
    • /
    • 2014
  • The rural area has aged and depressed for urban area in Korea. Furthermore, the rural house has deteriorated and is vulnerable to disaster which collapse, fire, landslide, and so on. For this matter, it need to an evaluated system for deteriorated level of rural house. The evaluated system has a repairing method and an estimated cost for rural house to offer native in rural area. This study could draw evaluation factor for deteriorated level of rural house as a basic study for the evaluated system. The evaluation factors is compared the Korean housing performance grade indication system, the Korean green building certification criteria, and the Japanese housing performance indication system. As a result, they could eight types. There are a mothproof, an waterproof, a finishing material, an asbestos cement slate of roofing, a mobility right, an opening and closing of doors and windows, an indoor environment.

  • PDF

A Study on the Heat Hazard Assessment of Building Wood (건축용 목재의 열 유해성 평가에 대한 연구)

  • Woo, Tae-Young;Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.6-14
    • /
    • 2018
  • This study was carried out with respect to the heat release rate (HRR) properties of building wood. Heat release characteristics were measured using a cone calorimeter (ISO 5660-1) with four kinds of wood. The time to ignition measured after the combustion in $25kW/m^2$ external heat flux was 35 to 55 s. Time to ignition of both lauan and red pine was marked with the most delayed value in each of 54 s, 55 s. The maximum heat release rate ($HRR_{peak}$) was $156.87{\sim}235.1kW/m^2$, and the risk of early fire was highest in spruce. Total heat release of red pine was obtained in the highest value with $114.2MJ/m^2$. The mean effective heat of combustion of Japanese cedar was 19.1 MJ/kg and the highest among the samples. Fire risk of wood by FPI was orderly increased from lauan ($0.2468s{\cdot}m^2/kW$), red pine ($0.2339s{\cdot}m^2/kW$), spruce ($0.2308s{\cdot}m^2/kW$) to Japanese cedar ($0.2231s{\cdot}m^2/kW$). Fire risk of wood by FGI get increased from lauan ($0.5088kW/m^2{\cdot}s$), red pine ($0.5111kW/m^2{\cdot}s$), Japanese cedar ($2.8522kW/m^2{\cdot}s$) to spruce ($3.0662kW/m^2{\cdot}s$). Therefore, the risk of fire on the heat release characteristics of woods were found that spruce and Japanese cedar showed the high value compared with the other specimens.

Rating Evaluation of Fire Risk for Combustible Materials in Case of Fire (화재 시 연소성 물질에 대한 화재 위험성 등급 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.75-82
    • /
    • 2021
  • This study investigated the fire risk assessment of woods and plastics for construction materials, focusing on the fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) by a newly designed method. Japanese cedar, red pine, polymethylmethacrylate (PMMA), and polyvinyl chloride (PVC) were used as test pieces. Fire characteristics of the materials were investigated using a cone calorimeter (ISO 5660-1) equipment. The fire performance index-III measured after the combustion reaction was found to be 1.0 to 15.0 with respect to PMMA. Fire risk by fire performance index-III increased in the order of PVC, red pine, Japanese cedar, and PMMA. The fire growth index-III was found to be 0.5 to 3.3 based on PMMA. Fire risk by fire growth index-III increased in the order of PVC, PMMA, red pine, and Japanese cedar. COpeak concentrations of all specimens were measured between 106 and 570 ppm. In conclusion, it is understood that Japanese cedar with a low bulk density and PMMA containing a large amount of volatile organic substances have a low fire performance index-III and high fire growth index-III, and thus have high fire risk due to fire. This was consistent with the fire risk index-IV.