• Title/Summary/Keyword: J-적분

Search Result 290, Processing Time 0.032 seconds

A Design of a Reconfigurable 4th Order ΣΔ Modulator Using Two Op-amps (2개의 증폭기를 이용한 가변 구조 형의 4차 델타 시그마 변조기)

  • Yang, Su-Hun;Choi, Jeong-Hoon;Yoon, Kwang Sub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.51-57
    • /
    • 2015
  • In this paper, in order to design the A / D converter with a high resolution of 14 bits or more for the biological signal processing, CMOS delta sigma modulator that is a 1.8V power supply voltage - were designed. we propose a new structure of The fourth order delta-sigma modulator that needs four op amps but we use only two op amps. By using a time -interleaving technique, we can re-construct the circuit and reuse the op amps. Also, we proposed a KT/C noise reduction circuit to reduce the thermal noise from a noisy resistor. We adjust the size of sampling capacitor between sampling time and integrating time, so we can reduce almost a half of KT/C noise. The measurement results of the chip is fabricated using a Magna 0.18um CMOS n-well1 poly 6 metal process. Power consumption is $828{\mu}W$ from a 1.8V supply voltage. The peak SNDR is measured as a 75.7dB and 81.3dB of DR at 1kHz input frequency and 256kHz sampling frequency. Measurement results show that KT/C noise reduction circuit enhance the 3dB of SNDR. FOM of the circuit is calculated to be 142dB and 41pJ / step.

Design of a Inverter-Based 3rd Order ΔΣ Modulator Using 1.5bit Comparators (1.5비트 비교기를 이용한 인버터 기반 3차 델타-시그마 변조기)

  • Choi, Jeong Hoon;Seong, Jae Hyeon;Yoon, Kwang Sub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.39-46
    • /
    • 2016
  • This paper describes the third order feedforward delta-sigma modulator with inverter-based integrators and a 1.5bit comparator for the application of audio signal processing. The proposed 3rd-order delta-sigma modulator is multi-bit structure using 1.5 bit comparator instead of operational amplifier. This delta-sigma modulator has high SNR compared with single-bit 4th-order delta-sigma modulator in a low OSR. And it minimizes power consumes and simplified circuit structure using inverter-based integrator and using inverter-based integrator as analogue adder. The modulator was designed with 0.18um CMOS standard process and total chip area is $0.36mm^2$. The measured power cosumption is 28.8uW in a 0.8V analog supply and 66.6uW in a 1.8V digital supply. The measurement result shows that the peak SNDR of 80.7 dB, the ENOB of 13.1bit and the dynamic range of 86.1 dB with an input signal frequency of 2.5kHz, a sampling frequency of 2.56MHz and an oversampling rate of 64. The FOM (Walden) from the measurement result is 269 fJ/step, FOM (Schreier) was calculated as 169.3 dB.

Evaluation of Pressure-Temperature Limit Curve for the Safe Operation of an RFV based on 3-D Finite Element Analyses (유한요소해석을 이용한 원자로용기 압력-온도 한계곡선의 평가)

  • Lee, Taek-Jin;Park, Yun-Won;Lee, Jin-Ho;Choe, Jae-Bung;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1567-1574
    • /
    • 2001
  • In order to operate an RPV safely it is necessary to keep the pressure-temperature (P-T) limit during the heatup and cooldown process. While the ASME Code provides the P-T limit curve for safe operation, this limit curve has been prepared under conservative assumptions In this paper the effects of conservative assumptions involved in the P-T limit curve specified in the ASME Code Sec. XI were investigated. Three different parameters the crack depth the cladding thickness and the cooling rate, were reviewed based on 3-D finite element analyses. Also the constraint effect on P-T limit curve generation was investigated based on J- T approach. It was shown that the crack depth and the constraint effect change the safe region in P-T limit curve significantly Therefore it is recommended to prepare a more precise P-T limit curve based on finite element analysis to obtain P-T limit for safe operation of an RPV.

Elastic-plastic Fracture Mechanics Analyses for Burst Pressure Prediction of Through-wall Cracked Tubes (관통균열 세관의 파열압력 예측을 위한 탄소성 파괴역학 해석)

  • Chang Yoon-Suk;Moon Seong-In;Kim Young-Jin;Hwang Seong-Sik;Kim Joung-Soo;Kim Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.10 s.241
    • /
    • pp.1361-1368
    • /
    • 2005
  • The structural and leakage integrity of steam generator tubes should be sustained all postulated loads with appropriate margin even if a crack is present. During the past three decades, for effective integrity evaluation, several limit load solutions have been used world-widely. However, to predict accurately load carrying capacities of specific components under different conditions, the solutions have to be modified by using lots of experimental data. The purpose of this paper is to propose a new burst pressure estimation scheme based on fracture mechanics analyses for steam generator tube with an axial or circumferential through-wall crack. A series of three dimensional elastic-plastic finite element analyses were carried out and, then, closed-form estimation equations with respect to both J-integral and crack opening displacement were derived through reference stress method. The developed engineering equations were utilized for structural integrity evaluation and the resulting data were compared to the corresponding ones fiom experiments as well as limit load solutions. Thereafter, since the effectiveness was proven by promising results, it is believed that the proposed estimation scheme can be used as an efficient tool for integrity evaluation of cracked steam generator tubes.

p-Version Finite Element Model for Computation of the Stress Intensity Factors of Cracked Panels under Mixed Mode (혼합모우드를 받는 균열판의 응력확대계수 산정을 위한 p-Version 유한요소 모델)

  • 윤영필;이채규;우광성
    • Computational Structural Engineering
    • /
    • v.9 no.2
    • /
    • pp.133-142
    • /
    • 1996
  • In this paper, two different techniques for mixed-mode type engineering fracture mechanics are investigated to estimate the stress intensity factors by using p-version finite element model. These two techniques are displacement extrapolation with COD and CSD method and J-integral with decomposition method. By decomposing the displacement field obtained from p-version of finite element analysis into symmetric and antisymmetric displacement fields with respect to the crack line, Mode-I and Mode-II stress intensity factors can be determined using aforementioned techniques. The example problems for validating the proposed techniques are centrally and centrally oblique cracked panels under tension. The numerical results associated with the variation of oblique angle and the ratio of crack length and panel width (a /W ratio) are compared with those by theoretical values and empirical solutions in literatures. Very good agreements with the existing solutions are shown.

  • PDF

A Study on an Integral State Feedback Controller for Way-point Tracking of an AUV (무인잠수정의 적분 상태 궤환 제어기 설계 및 경유점 추적 연구)

  • Bae, Seol B.;Shin, Dong H.;Park, Sang H.;Joo, Moon G.
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.8
    • /
    • pp.661-666
    • /
    • 2013
  • A state feedback controller with integration of output error is proposed for way-point tracking of an AUV (Autonomous Underwater Vehicle). For the steering control on the XY plane, the proposed controller uses three state variables (sway velocity, yaw rate, heading angle) and the integral of the steering error, and for the depth control on the XZ plane, it uses four state variables (pitch rate, depth, pitch angle) and the integral of the depth error. From the simulation using Matlab/Simulink, we verify that the performance of the proposed controller is satisfactory within an error range of 1m from the target way-point for arbitrarily chosen sets of consecutive way-points.

Robust Torque Control for an Internal Combustion Engine with Nonlinear Uncertainty (비선형 불확실성을 갖는 내연기관의 강인한 토크제어)

  • Kim, Y.B.;Kim, J.H.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.43-50
    • /
    • 2009
  • If an internal combustion engine is operated by consolidated control, the minimum fuel consumption is achieved satisfying the demanded objectives. For this, it is necessary that the engine is operated on the ideal operating line which satisfies minimum fuel consumption. In this context of view, there are many tries to achieve given object. However, the parameter in the internal combustion engines are variable and depend on the operating points. Therefore, it is necessary to cope with the uncertainties such that the optimal operating may be possible. From this point of view, this paper gives a controller design method and a robust stability condition for engine torque control which satisfies the given control performance and robust stability in the presence of physical parameter perturbation. Exactly, the present paper considers a robust stability of this 2DOF servosystem with nonlinear type uncertainty in the engine system, and a robust stability condition for the servosystem is introduced. This result guarantees that if the plant uncertainty is in the permissible set defined by the given condition then a gain tuning can be carried out to suppress the influence of the plant uncertainties.

  • PDF

Mechanism and Measure of Chaotic Mixing in a Single-screw Extruder (단축 압축기에서의 카오스 혼합의 메카니즘과 혼합성능 정량와)

  • 권태헌
    • The Korean Journal of Rheology
    • /
    • v.8 no.1
    • /
    • pp.11-29
    • /
    • 1996
  • 스크류 채널 내에 주기적을 배리어를 설치함으로써 단축 스크류 압출 공정에서의 혼합 성능이 높여질수 있음이 S.J. Kim과 T.H. Kwom에 의해 밝혀진 바있다. 그들은 이새 로운 스크류를 통한 혼합이 카오틱하는 점으로부터 이 새로운 스크류를 카오스 스크류라고 명명했다. 우리는 카오스 스크류가 장착된 단축 압출공정에서 역학계 이론과 혼합운동학을 연계하여 연구를 수행하였다. 포인카레 단면을 통한 연구로부터 우리는 배리어의 배열이 islan의 크기에 대단히 밀접하게 관련되어 있음을 발견하였다. 연속적인 쉘 변형은 카오틱 유동에서 유체 요소를 지수 함수 형태로 늘이는 늘임과 접힘으로 이루어진 카오틱 혼합 메 카니즘을보여준다. 유체요소의 국부 늘임은 원리상으로는 계산되어질수 있으나 수치 해석상 의 어려운 점이 있다. 정규 유동에서와 달리 카오틱 유동에서는 입자 추적이 Runge-Kutta 적분중의 시간간격에 대단히 민감하다. 그래서 실제 사용될수 있는 시간 간격에 의해 계산 된 국부 늘임율 및 혼합효율의 정확도가 보장되어지지 않는다. 이러한 점들을 고려하여 우 리는 새로운 혼합 척도로 $\sigma$z를 제안하는데 이값은 비교적 긴 유체선분이 채널방향을 따라 늘어나는 비에 관련된 값이다. 배리어 영역의 길이가 짧을수록 $\sigma$z는 큰값으로 나타나지만 포인카레 단면에 의한 연구에 따르면 배리어의 주기가 너무 짧다면 두 개의 거대한 island 가 존재하는 것으로 밝혀졌다. 그리고 이러한 사실은 유체요소의 늘임비가 크다는 것이 항 상 좋은 혼합성능을 뜻하는 것은 아니라는 점을 보여준다. 이러한 관점에서 볼 때 혼합 스 크류를 설계하는데 있어서는 포인카레 단면을 병행하여 ${\sigma}_z$의 값을 사용하는 것이 바람직할 것이다.

  • PDF

A Numerical Study of a Free Molecular Flow in the Turbomolecular Pump (터보 분자 펌프(Turbomolecular pump)내의 자유 분자 유동에 관한 수치 해석적 연구)

  • Hwang, Y.K.;Heo, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.219-229
    • /
    • 1996
  • In the free molecular flow range, the pumping performance of a turbomolecular pump has been predicted by calculation of the transmission probability employing the integral method and the test particle Monte-Carlo method. The velocities of molecules incident upon a moving blade are given by the random numbers, which are sampled from the Maxwell molecular velocity distribution function. The present results agree quantitatively with the previous known numerical results. For a multi-stage pump, the velocity profile of molecules between two blade rows is not Maxwell distribution. In this case, the Monte-Carlo method is employed to calculate the overall transmission probability for the entire set of blade rows. When the results of the approximate method combining the single stage solutions are compared with those of the Monte-Carlo method for the pump having six rows at C=0.6, the approximate method overestimates as much as 36% in the maximum compression ratio and 19% in the maximum pumping speed than does the Mote-Carlo method.

  • PDF

Design and Analysis of a Switching State Feedback Controller to Reduce the Measurement Error Effect for a Chain of Integrators System under AC and DC Noise (AC와 DC 노이즈가 있는 적분기 시스템에서 측정에러의 영향을 감소시키는 스위칭 상태 궤환 제어기의 설계 및 분석)

  • Oh, Sang-Young;Choi, Ho-Lim
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.1
    • /
    • pp.12-17
    • /
    • 2014
  • In this paper, we propose a controller capable of reducing the effect of measurement errors under AC and DC noise. Typically, the control system measures data through a sensor. If sensor noise is included in a controller via the feedback channel, the signal is distorted and the entire system cannot work normally. Therefore, some appropriate action to counter the measurement error effect is essential in the controller design. Our controller is equipped with a gain-scaling factor and a compensator to reduce the effect of measurement error in the feedback signal. Also, we use a switching control strategy to enhance the performance of the controller regarding convergence speed. Our proposed controller can therefore effectively reduce the AC and DC noise of the sensor. We analyze the proposed controller by Laplace transform technique and our control method is verified via MATLAB simulation.