• 제목/요약/키워드: Isolation

검색결과 9,237건 처리시간 0.036초

하모닉 밸런스법을 이용한 비선형 진동절연 시스템의 근사적 응답 (Approximate Response of a Non-linear Vibration Isolation System Using the Harmonic Balance Method)

  • 이건명
    • 한국기계가공학회지
    • /
    • 제17권6호
    • /
    • pp.124-129
    • /
    • 2018
  • A non-linear vibration isolation system which is composed of a non-linear spring and a linear damper was proposed in past research. When the support of the isolation system is excited harmonically, the response component of the isolation system mass at the excitation frequency has been calculated approximately using the harmonic balance method. The response was approximated by a single mode, and the result was compared with a numerical result which is assumed as an accurate one. Next, the response was approximated by two modes, and the result was compared with the former one.

INTEGRATION OF CONSTRUCTION TECHNIQUES FOR SPECIAL ISOLATION WARDS OF HOSPITAL BUILDINGS

  • Chi-Su Tai ;Sy-Jye Guo
    • 국제학술발표논문집
    • /
    • The 1th International Conference on Construction Engineering and Project Management
    • /
    • pp.627-632
    • /
    • 2005
  • The severe acute respiratory syndrome -SARS virus spreaded rapidly in Asia in 2003 caused a lethal and serious epidemic. Establishing special isolation wards of high-level epidemic prevention has becomes one of the most important tasks of epidemic prevention. Taking the biosafety level of US CDC biology laboratory as an example, the laboratory of the highest level, BL4 and that of the second high level, BL3 are only allowed to handle and research this kind of highly dangerous viruses safely, to ensure the safety of researchers and the surrounding environment.This research aims to study the functions and the design requirements of "special isolation wards", which is equivalent to the high-level biotechnology laboratory, and have an integrated discussion about the design and construction techniques of this kind of wards, expecting to provide a reference for constructing special isolation wards and maintaining operation safely in Taiwan.

  • PDF

Analysis of soft deformation limitation of base-isolated structures

  • Jinwei Jiang;Baoyang Yang
    • Earthquakes and Structures
    • /
    • 제26권1호
    • /
    • pp.1-15
    • /
    • 2024
  • Isolation technology has been proven effective in reducing the seismic response of superstructures, where most of the deformation is concentrated in the isolation layer. However, in cases of earthquakes with intensities surpassing the fortification level of the area, or severe near-fault earthquakes, the isolation layer may experience excessive deformation, resulting in damage to the isolation bearings or collisions with the retaining wall or surrounding buildings. In this study, a finite element model using ABAQUS is established and compared with experimental test results to deeply investigate the influence of limit devices on the isolation layer and its response to the superstructure. The findings reveal that a larger limiter stiffness and a smaller reserved gap can achieve a more effective limiting effect. Nevertheless, a smaller reserved gap and a larger limiter stiffness may result in increased response of the superstructure. Therefore, rational selection of the reserved gap and limiter stiffness is crucial to reduce the acceleration response.

낮은 변환손실과 높은 LO-RF 격리도 특성을 갖는 94 GHz Resistive Mixer 의 제작 (Fabrications of Low Conversion Loss and High LO-RF Isolation 94 GHz Resistive Mixer)

  • 이복형;이진구
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.921-924
    • /
    • 2005
  • We report low conversion loss and high LO to RF isolation 94 GHz MMIC resistive mixers based on 0.1 ${\mu}m$ InGaAs/InAlAs/GaAs metamorphic HEMT technology. The fabricated resistive mixers applied a one-stage amplifier on RF port of the mixer. By using the one-stage amplifier, we obtained the decrement of conversion loss and the increment of LO to RF isolation. So, we can obtain higher performances than conventional resistive mixers. The modified mixer shows excellent conversion loss of 6.7 dB at a LO power of 10 dBm. We also observed an extremely high isolation characteristic from the MMICs exhibiting the LO-RF isolation of 21 ${\pm}$ 0.5dB in a frequency range of 93.7${\sim}$ 94.3 GHz. The low conversion loss and high LO-RF isolation characteristics of the MMIC modified resistive mixers are mainly attributed to the performance of the MHEMTs exhibiting a maximum transconductance of 654 mS/mm, a current gain cut-off frequency of 173 GHz and a maximum oscillation frequency of 271 GHz.

  • PDF

A Low Insertion-Loss, High-Isolation Switch Based on Single Pole Double Throw for 2.4GHz BLE Applications

  • Truong, Thi Kim Nga;Lee, Dong-Soo;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권3호
    • /
    • pp.164-168
    • /
    • 2016
  • A low insertion-loss, high-isolation switch based on single pole double throw (SPDT) for a 2.4GHz Bluetooth low-energy transceiver is presented in this paper. In order to increase isolation, the body floating technique is implemented. Based on characteristics whereby the ratio of the sizes of the shunt and the series transistors significantly affect the performance of the switches, the device sizes are optimized. A simple matching network is also designed to enhance the insertion loss. Thus, the SPDT switch has high isolation and low insertion loss without increasing the complexity of the circuit. The proposed SPDT is designed and simulated in a complementary metal-oxide semiconductor 65nm process. The switch has a $530{\mu}m{\times}270{\mu}m$ area and achieves 0.9dB, 1.78dB insertion loss and 40dB, 41dB isolation of transmission, reception modes, respectively.

Optimal design of bio-inspired isolation systems using performance and fragility objectives

  • Hu, Fan;Shi, Zhiguo;Shan, Jiazeng
    • Structural Monitoring and Maintenance
    • /
    • 제5권3호
    • /
    • pp.325-343
    • /
    • 2018
  • This study aims to propose a performance-based design method of a novel passive base isolation system, BIO isolation system, which is inspired by an energy dissipation mechanism called 'sacrificial bonds and hidden length'. Fragility functions utilized in this study are derived, indicating the probability that a component, element, or system will be damaged as a function of a single predictive demand parameter. Based on PEER framework methodology for Performance-Based Earthquake Engineering (PBEE), a systematic design procedure using performance and fragility objectives is presented. Base displacement, superstructure absolute acceleration and story drift ratio are selected as engineering demand parameters. The new design method is then performed on a general two degree-of-freedom (2DOF) structure model and the optimal design under different seismic intensities is obtained through numerical analysis. Seismic performances of the biologically inspired (BIO) isolation system are compared with that of the linear isolation system. To further demonstrate the feasibility and effectiveness of this method, the BIO isolation system of a 4-storey reinforced concrete building is designed and investigated. The newly designed BIO isolators effectively decrease the superstructure responses and base displacement under selected earthquake excitations, showing good seismic performance.

SOC 테스팅을 위한 효율적인 부분 분리 링 (An Efficient Partial Isolation Ring Technique for SOC Testing)

  • 김문준;이영균;김석윤;장훈
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제28권10호
    • /
    • pp.541-547
    • /
    • 2001
  • 코이를 기초로 설계된 칩을 테스팅 하기 위해서는 각 코어로의 테스트 데이터 접근을 위해 완전히 분리 링 필요하다. 부분 분리 링은 코어를 둘러싸고 있는 분리 링의 크기를 줄이고 분리 링으로써의 역할을 모두 수행한다. 본 논문에서는 기존의 방법들보다 부분 분리 링의 크기를 더욱 작게 하고 해법을 찾는 데 걸리는 시간보다 줄일수 있는 효율적인 방법을 제시한다. 이를 위해 테스트 가능도에 기반을 둔 효율적인 순위 결정 기법을 적용하였으며 SOC 테스팅의 특성을 살린 정렬 기법을 적용하였다. 실험결과에서 기존의 방법들보다 본 논문에 제시된 방법이 실제로 유용하다는 것을 보여준다.

  • PDF

GaAs MMIC상에서 주기적 접지구조를 가지는 결합선로의 절연특성에 관한 연구 (A Study on Characteristics of Coupled Line Employing Periodical Ground Structure on GaAs MMIC)

  • 김세호;강석엽;윤영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.159-165
    • /
    • 2009
  • In this study, using a periodical ground structure(PGS) on GaAs monolithic microwave integrated circuit(MMIC), transmission line with a high isolation characteristic was developed for application to compact signal/bias lines of highly integrated MMIC. And the origin of the high isolation characteristic was theoretically investigated. The high isolation characteristic was originated from a resonance between adjacent microstrip lines employing PGS. With only a spacing of $20{\mu}m$, the coupled microstrip line employing PGS showed an isolation value of -47 dB at 60 GHz. The frequency range for high isolation was easily controlled by changing the PGS structure. Above results indicate that microstrip lines employing PGS are very useful for application to compact signal/bias lines of highly integrated MMIC requiring a high isolation characteristics between lines. In addition, equivalent circuit employing closed-form equation for the coupled line with PGS was also extracted.

폐고무를 이용한 공공주택 층간소음차단 시스템 (Floor Noise Isolation System of the Residential Buildings Using Waste Rubbers)

  • 오정석;서재찬;김진국
    • 공업화학
    • /
    • 제28권4호
    • /
    • pp.427-431
    • /
    • 2017
  • 최근 공동주택이 증가함에 따라 층간소음문제가 증가하고 있다. 이로 인해 더 효과적인 층간소음저감 시스템이 요구되고 있다. 향후 고층빌딩이 더 많이 건설될 것이므로 이런 시스템은 시장에서 더욱 수요가 요구되어지는 중요한 기술이다. 본 연구에서는 폐고무를 이용하여 신규 바닥 소음 저감 판넬을 설계하고 제작하였다. 실험실 및 실제 필드조건에서 소음 저감을 조사하였다. Field test 결과 경량 및 중량충격음 레벨이 각각 52, 48 dB로 우수한 결과를 보였다. 기존 구조 대비하여 22~42 mm의 두께 저감을 할 수 있었다.

바닥충격음 완충재의 동적특성과 소음저감 성능 비교 (Comparison Between the Dynamic Properties and Noise Isolation Performances for a Floor Impact Isolation Pad)

  • 양수영;이동훈;홍병국;송화영;이주원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.275-278
    • /
    • 2005
  • In this study, the dynamic properties of a floor impact sound isolation pad expressed in terms of the natural frequency, the dynamic stiffness per unit area and the loss factor are measured by the resonant method. By using the measured dynamic properties, the vibration transmissibility diagram is obtained for each isolation pad, which is compared with the values tested by the impact sound sources at the room in an apartment. From the comparative results, it is found that the noise reduction Performances. of isolation pads are closely connected with the natural frequency and the dynamic stiffness per unit area.

  • PDF