Comparison Between the Dynamic Properties and Noise Isolation Performances for a Floor Impact Isolation Pad

바닥충격음 완충재의 동적특성과 소음저감 성능 비교

  • 양수영 (서울산업대학교 산업대학원) ;
  • 이동훈 (서울산업대학교 에너지환경대학원 에너지시스템공학과) ;
  • 홍병국 (서울산업대학교 에너지환경대학원) ;
  • 송화영 (서울산업대학교 에너지환경대학원) ;
  • 이주원 (서울산업대학교 소음진동연구센터)
  • Published : 2005.05.01

Abstract

In this study, the dynamic properties of a floor impact sound isolation pad expressed in terms of the natural frequency, the dynamic stiffness per unit area and the loss factor are measured by the resonant method. By using the measured dynamic properties, the vibration transmissibility diagram is obtained for each isolation pad, which is compared with the values tested by the impact sound sources at the room in an apartment. From the comparative results, it is found that the noise reduction Performances. of isolation pads are closely connected with the natural frequency and the dynamic stiffness per unit area.

Keywords