1 |
Kim, H.S. and Roschke, P.N. (2006), "Fuzzy control of base-isolation system using multi-objective genetic algorithm", Comput.-Aided Civil Infrastruct. Eng., 21(6), 436-449.
DOI
|
2 |
Kulkarni, J.A. and Jangid, R.S. (2002), "Rigid body response of base-isolated structures", Struct. Control Health Monit., 9(3), 171-188.
|
3 |
Mackie, K.R. (2005), Fragility-based seismic decision making for highway overpass bridges.
|
4 |
May, P.J. (2003), "Performance-based regulation and regulatory regimes: The saga of leaky buildings", Law & Policy, 25(4), 381-401.
DOI
|
5 |
Moeindarbari, H. and Taghikhany, T. (2014), "Seismic optimum design of triple friction pendulum bearing subjected to near-fault pulse-like ground motions", Struct. Multidiscip. O., 50(4), 701-716.
DOI
|
6 |
Nagarajaiah, S., Narasimhan, S. and Johnson, E. (2008), "Structural control benchmark problem: Phase ii-nonlinear smart base‐isolated building subjected to near-fault earthquakes", Struct. Control Health Monit., 15(5), 653-656.
DOI
|
7 |
Ramallo, J.C., Johnson, E.A. and Spencer Jr., B.F. (2002), " 'Smart' base isolation systems", J. Eng. Mech., 128(10), 1088-1099.
DOI
|
8 |
Scruggs, J.T., Taflanidis, A.A. and Beck, J.L. (2006), "Reliability-based control optimization for active base isolation systems", Struct. Control Health Monit., 13(2‐3), 705-723.
DOI
|
9 |
Kelly, J.M. (1997), Earthquake-resistant design with rubber, Springer London.
|
10 |
Shan, J., Shi, Z., Hu, F., Yu, J. and Shi, W. (2018), "Stochastic optimal design of novel nonlinear base isolation system for seismic-excited building structures", Struct. Control Health Monit., e2168. https://doi.org/10.1002/stc.2168
DOI
|
11 |
Skinner, R.I., Robinson, W.H. and McVerry, G.H. (1993), An introduction to seismic isolation, John Wiley & Sons.
|
12 |
Taghavi, S. and Miranda, E. (2003), Response assessment of nonstructural building elements, Pacific Earthquake Engineering Research Center.
|
13 |
Yang, H.T.Y., Lin, C.H., Bridges, D. et al. (2010), "Bio-inspired passive actuator simulating an abalone shell mechanism for structural control", Smart Mater. Struct., 19(10), 105011.
DOI
|
14 |
Chen, X., Yang, H.T.Y., Shan, J. et al. (2016), "Bio-inspired passive optimized base-isolation system for seismic mitigation of building structures", J. Eng. Mech., 142(1), 04015061.
DOI
|
15 |
FEMA, P. (2012), "58-1 seismic performance assessment of buildings (volume 1-methodology)", Federal Emergency Management Agency, Washington.
|
16 |
Hansma, P.K., Fantner, G.E., Kindt, J.H. et al. (2005), "Sacrificial bonds in the interfibrillar matrix of bone", J. Musculoskelet Neuronal Interact, 5(4), 313-315.
|
17 |
Jangid, R. and Kelly, J. (2001), "Base isolation for near-fault motions", Earthq. Eng. Struct. D., 30(5), 691-707.
DOI
|
18 |
Kaynia, A.M., Taucer, F. and Hancilar, U. (2013), Guidelines for deriving seismic fragility functions of elements at risk: Buildings, lifelines, transportation networks and critical facilities, Publications Office.
|