• Title/Summary/Keyword: Irradiation effect

Search Result 2,381, Processing Time 0.043 seconds

Dosimetric Characteristics on Penumbra Regions of the Multileaf Collimator as Compared with the Lead Alloy Block (다엽 콜리메이터(Multileaf Collimator)와 합금납 차폐물(Lead Alloy Block)의 반 그림자영역의 선량 분포상의 특성 비교)

  • Lee Sang Wook;Oh Young Tack;Kim Woo Cheol;Keum Ki Chang;Yoon Seong Ick;Kim Hyun Soo;Park Won;Chu Seong Sil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.391-396
    • /
    • 1995
  • Purpose : The Conformal Radiation Therapy has bee widely used under favour of development of computer technologies. The delivery of a large number of static radiation fields are being necessary for the conformal irradiation. In this paper we investigate dosimetric characteristics on penumbra regions of a multileaf collimator(MLC), and compare to those of lead alloy block for the optimal use of the system in 3-D conformal radiotherapy. Materials and Methods : The measurement of penumbra by MLC or lead alloy block was performed with 6 or 10 MV X-rays. The film was positioned at a dmax depth and 10 cm depth, and its optical density was determined using a scanning videodensitometer. The effective penumbra, the distance from $80{\%}$ to $20{\%}$ isodose lines and $90{\%}$ to $10{\%}$ were analyzed as a function of the angle between the direction of leaf motion and the edge defined by leaves. Results : Increasing MLC angle ($0-75^{\circ}$) was observed with increasing the penumbra widths and the scalloping effect. There was no definite differences of penumbra width from $80{\%}$ to $20{\%}$ isodose lines, while being the small increase of penumbra width from $90{\%}$ to $10{\%}$ isodose line varing the depth and energy. The effective penumbra width of lead alloy block are agree resonably with those of MLC within 4.8mm. Conclusion : The comparative qualitative study of the penumbra between MLC and lead alloy block demonstrate the clinical acceptability and suitability of the multileaf collimator for 3-D conformal radiotherapy.

  • PDF

A STUDY ON THE EFFECT OF THE ND:YAG LASER IRRADIATION ON THE MECHANICALLY EXPOSED PULP (기계적 노출치수의 Nd:YAG 레이저 조사효과에 대한 연구)

  • Lee, Sang-Ho;Lee, Chang-Seop;Kim, Su-Gwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.146-158
    • /
    • 2002
  • The purpose of this study was to investigate the effects of Nd:YAG laser on mechanically exposed pulp of dog by the observation of pulpal inflammatory change and heal process including dentinal bridge, structural changes of fibroblasts of thr remaining vital pulp tissue. In experimental group 1, the exposed pulps were irradiated with Nd:YAG laser(3W, 30Hz, 0.2sec) for $2{\sim}3$ second followed by capped with aluminium tin foil. In group 2 and group 3, the exposed pulps were irradiated with Nd:YAG laser via contact(Group 2) and non-contact(Group 3) methods followed by capped with calciumhydroxide paste. The animal were sacrificed at the intervals of 3, 7, 14 and 30days for histologic evaluation. The results were as follows : 1. The dentinal bridges were formwd more fast and broadly in the experimental group 1 and 2 than other groups, but there were no histologic differences in the degree of their formation among control group, experimental group 1. 2. Odontoblastic activities at amputated pulp was increased in the experimental group 2, 3 than other group but there no histologic difference in the odontblastic activitiy among control group, experimental group 1. 3. The infalmmation was severe at the postoperative 1 week of all groups, but its condition subsideed with time elapsed. At the postoperative 3, 7 days, its condition in experimental group 2, 3 were less severe than in the group 1. 4. There were no histologic differences between the experimental group 2 and 3 according to the degree of dentin bridge formation.

  • PDF

Analysis of the Volatile Flavor Components in Plum ($Prunus$ $salicina$) Irradiated with an Electron Beam (전자선 조사한 자두의 휘발성 유기성분 변화)

  • Jeong, In-Seon;Lee, Sun-Im;Jeon, Dong-Bok;Hong, Young-Sin;Kim, Jae-Sung;Choi, Sung-Hwa;Nho, Eun-Yeong;Choi, Ji-Yeon;Kim, Byung-Sook;Kim, Kyong-Su
    • Food Science and Preservation
    • /
    • v.19 no.2
    • /
    • pp.249-256
    • /
    • 2012
  • The changes in the volatile organic compounds in plum after its electron beam irradiation and storage were determined using the simultaneous distillation extraction method and gas chromatograph-mass spectrometry. There were 44, 46, 45, 47, and 38 volatile compounds in the 0-, 0.25-, 0.5-, 0.75-, and 1 kGy irradiated samples, respectively. Also, the volatile flavor components of the plum that was stored for 30 days were identified as 48, 40, 40, 39, and 40 components. The compositions of the volatile compounds of the control and irradiated samples showed a similarity after the storage. Especially, the more important volatile flavor of the plum was identified as hexanal of the C6compounds, (E)-2-hexenal and (Z)-3-hexenal. In particular, hexanal, (E)-2-hexenal, and (Z)-3-hexen-1-ol increased in all the doses, where as hexanol and (E)-2-hexen-1-ol decreased. Among the lactone compounds, ${\gamma}$-hexalactone, ${\gamma}$-octalactone, and ${\gamma}$-decalactone were identified during the storage period in the raw samples. Hexanonic acid and 2-hexenoic acid were not identified during the storage of the samples, and 2-methylprrole was detected only when the storage samples were irradiated at a dose higher than 0.5kGy. Therefore, it was shown that there was no effect on the variation of the volatile organic component suntil 1 kGy in the plum was irradiated with an electron beam.

Chlorophyll Fluorescence, Chlorophyll Content, Graft-taking, and Growth of Grafted Cucumber Seedlings Affected by Photosynthetic Photon Flux of LED Lamps (LED 램프의 광합성유효광양자속이 오이접목묘의 엽록소형광, 엽록소함량, 활착 및 생장에 미치는 영향)

  • Kim, Hyeong Gon;Lee, Jae Su;Kim, Yong Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.231-238
    • /
    • 2018
  • Chlorophyll fluorescence, chlorophyll content, graft-taking and growth of grafted cucumber seedlings as affected by photosynthetic photon flux (PPF) of LED lamps were analyzed in this study. Four PPF levels, namely 25, 50, 100, $150{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ were provided to investigate the effect of light intensity on the chlorophyll fluorescence, chlorophyll content, graft-taking and growth of grafted cucumber seedlings. Air temperature, relative humidity, and photoperiod for graft-taking were maintained at $25^{\circ}C$, 90%, $16h{\cdot}d^{-1}$, respectively. Maximum quantum yield (Fv/Fm) of rootstock as affected by PPF was found to be 0.84-0.85 and there was no significant change in Fv/Fm. Even though Fv/Fm of scion measured at 2 days after grafting was lowered to 0.81-0.82, after then it gradually increased with increasing PPF. At 4 days after grafting, the chlorophyll content extracted from scion increased with increasing PPF. Graft-taking ratio of grafted cucumber seedlings was 90-95% as PPF was ranged from $25{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ to $100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. However, the graft-taking ratio of grafted seedlings healed under PPF of $150{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ was decreased to 80%. Maximum PPF measured required for smooth joining of rootstock and scion was assumed to be $100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. At healing stage of grafted cucumber seedlings, Fv/Fm of scion decreased and at least two days after grafting were required for rooting of grafted seedlings. Chlorophyll fluorescence response of rootstock and scion was linked to light irradiation. Therefore, it was concluded that physical environment including light and humidity during healing process of grafted seedlings should be controlled more precisely to facilitate root formation and to prevent scion from lowering Fv/Fm. Further studies are required to investigate the effects of root development and joining of vascular bundles of grafted seedlings on the chlorophyll content of scion.

Antioxidant and Cellular Protective Effects of Moringa oleifera Leaves Extract (드럼스틱 잎 추출물의 항산화 및 세포보호 효과)

  • Xuan, Song Hua;Kim, A Rang;Jeong, Yoon Ju;Lee, Nan Hee;Park, Soo Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.3
    • /
    • pp.217-226
    • /
    • 2016
  • In this study, we investigated the antioxidative and cellular protective effects on HaCaT cells and erythrocytes of Moringa oleifera (M. oleifera) leaves extract and its fractions. All experiments were performed with 50% ethanol extract, ethyl acetate fraction and aglycone fraction of M. oleifera leaves. The free radical scavenging activity ($FSC_{50}$) of the extract and fractions of M. oleifera leaves were in the following order: 50% ethanol extract ($77.10{\mu}g/mL$) < ethyl acetate fraction ($20.63{\mu}g/mL$) < aglycone fraction ($17.00{\mu}g/mL$) by using the 1, 1-diphenyl-2-picrylhydrazyl. In $Fe^{3+}-EDTA/H_2O_2$ system using the luminol, reactive oxygen species (ROS) scavenging activities (total antioxidant capacity, $OSC_{50}$) of aglycone fraction ($OSC_{50}=0.63{\mu}g/mL$) was the strongest among all extracts, which was much higher than L-ascorbic acid ($1.50{\mu}g/mL$). In the $^1O_2$-induced cellular damage of erythrocytes, the cellular protective effects of 50% ethanol extract (${\tau}_{50}=46.9min$) and aglycone fraction (${\tau}_{50}=122.1min$) were higher than (+)-${\alpha}$-tocopherol (${\tau}_{50}=37.7min$), known as a lipophilic antioxidant at $10{\mu}g/mL$. After cell damage induced by $400mJ/cm^2$ UVB irradiation, the cellular protective effects of ethyl acetate and aglycone fraction of M. oleifera leaves extract were showed on the concentration from 0.20 to $1.56{\mu}g/mL$. These results suggest that M. oleifera leaves extract and its fractions can function as a natural antioxidant agent in cosmetics on skin exposed to UV radiation by protecting cellular membrane against ROS.

Antioxidant and Anti-wrinkling Effects of Aruncus dioicus var. kamtschaticus extract (눈개승마 추출물의 항산화 및 주름개선 효과)

  • Youn, Jin-Suk;Shin, Seung-Yong;Wu, Yongxiang;Hwang, Ju-Young;Cho, Jae-Ho;Ha, Yong-Geun;Kim, Jin-Ki;Park, Min-Jeong;Lee, Seon-Ho;Kim, Tae-Hoon;Kim, Tae-Wan
    • Food Science and Preservation
    • /
    • v.19 no.3
    • /
    • pp.393-399
    • /
    • 2012
  • In this study, the antioxidant and anti-wrinkling effects of extracts from Aruncus diocius var. kamtschaticus (ADV) were investigated. According to the results, the ethanol extract has better antioxidant and anti-wrinkling effects than the water extract. The amounts of total polyphenol and flavonoid compounds in the ethanol extract were 122 and 36 mg/g, respectively, while those in the water extract were 87 and 26 mg/g. The antioxidant activities of the ethanol and water extracts were 395 and 4,682 ${\mu}g/mL$ as the $RC_{50}$ values for the DPPH radical scavenging activity, and 227 and 366 ${\mu}g/mL$ for the $ABTS^+$ radical scavenging activity, respectively. The reducing power of the ethanol extract (1.58 at 2 mg/mL) was higher than that of the water extract (0.88 at 2 mg/mL). The astringent activities of the ethanol and water extracts were 91.27 and 16.35% at 10 mg/mL, respectively. Furthermore, the ADV ethanol extract treatment of the fibroblast cell after UV irradiation resulted in increased cell viability (10% at 100 ${\mu}g/mL$) and collagen biosynthesis (33% at 100 ${\mu}g/mL$), with a lowering in the MMP-1 expression level (16.8 % at 100 ${\mu}g/mL$). These results demonstrate that AVD provides a remarkable and significant tensor and anti-wrinkling effect on the skin, which could be of a great use in anti-aging skin care products.

Effect of Pulse Energy and Pulse Repetition Rate at the Identical Total Power During Enamel Ablation Using an Er:YAG Laser (Er:YAG 레이저를 이용한 치아 삭제시 동일출력에서 펄스에너지와 조사반복률의 영향)

  • Won, Jung-Yeon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.3
    • /
    • pp.223-229
    • /
    • 2006
  • The objectives of this study was to investigate the amount of tooth ablation and the change of intrapulpal temperature by Er:YAG laser as it relates to pulse energy and pulse repetition rate at the identical power and, thereby, to reveal which of the two parameters strongly relates with ablation efficiency and intrapulpal temperature. Extracted healthy human molar teeth were sectioned into two pieces and each specimen was irradiated within the combination of pulse energy and pulse repetition time at the same power of 3W; $300mJy{\times}10Hz$ group, $200mJy{\times}15Hz$ group, and $150mJy{\times}20Hz$ group. Each specimen comprised ten tooth specimens. A laser beam with conjunction of a water flow rate of 1.6 ml/min was applied over enamel surfaces of the specimens during 3 seconds and the ablation amount was determined by difference in weight before and after irradiation. To investigate the temperature change in the pulp according to the above groups, another five extracted healthy human molar teeth were prepared. Each tooth was embedded into resin block and the temperature-measuring probes were kept on the irradiated and the opposite walls in the dental pulp during lasing. When the power was kept constant at 3W, ablation amount increased with pulse energy rather than pulse repetition rate (p=0.000). Although intrapulpal temperature increased with pulse repetition rate, there were no significant differences among the groups and between the irradiated and the opposite pulpal walls, except at a condition of $150y{\times}20Hz$ (p=0.033). Conclusively, it is suggested that ablation efficacy is influenced by pulse energy rather than pulse repetition rate.

Beneficial Effect of an Agar Mask against Skin Damage Induced by UV Exposure in SKH-1 Hairless Mice (UV조사에 의해 유발된 SKH-1 hairless 마우스의 피부노화에 미치는 한천마스크의 개선효과)

  • Song, Bo Ram;Kim, Ji Eun;Yun, Woo Bin;Lee, Mi Rim;Choi, Jun Young;Park, Jin Ju;Kim, Dong Seob;Lee, Chung Yeoul;Lee, Hee Seob;Lim, Yong;Jung, Min Wook;Kim, Bae Hwan;Hwang, Dae Youn
    • Journal of Life Science
    • /
    • v.27 no.9
    • /
    • pp.975-985
    • /
    • 2017
  • To investigate the beneficial effects of an agar gel mask (AGM) on UV-induced photoaging, SKH-1 hairless mice were treated with a topical application of AGM and an AGM dipped in essence (AGMdE). The mice were divided into an no radiation group, UV + AGM, UV + AGMdE, and UV + vehicle (PBS) treatment groups. Alterations in skin wrinkles, skin phenotype, histological structures, oxidative status, and toxicity were then evaluated during 4 weeks of exposure. The topical application of AGM and AGMdE inhibited wrinkle formation, suppressed the erythema index, prevented transepidermal water loss, and enhanced skin hydration. In addition, epidermal thickness recovered to a similar level as that in the no irradiation group in the UV + AGM and UV + AGMdE treatment groups compared with the UV + vehicle (distilled water) group. Furthermore, the expression levels of matrix metalloproteinase-1 (MMP-1) and tyrosinase were reduced in the UV + AGM and UV + AGMdE treatment groups, although the highest level varied. Moreover, superoxide dismutase (SOD) activity was significantly lower in the UV + AGM and UV + AGMdE treatment groups as compared with the UV + vehicle group. No significant alterations induced by most toxic compounds were measured in serum biochemical markers and liver and kidney histological features of the UV + AGM and UV + AGMdE treatment groups. These results suggest that AGM may protect against skin aging by regulating skin morphology, histopathological structures, and oxidative conditions.

Radiation Dose of Lens and Thyroid in Linac-based Radiosurgery in Humanoid Phantom (선형가속기형 방사선수술시 인형 팬텀에서 수정체 및 갑상선 선량)

  • Kim, Dae-Yong;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.517-529
    • /
    • 1998
  • Purpose : Although many studies have investigated the dosimetric aspects of stereotactic radiosurgery in terms of target volume, the absorbed doses at extracranial sites: especially the lens or thyroid - which are sensitive to radiation for deterministic or stochastic effect -have infrequently been reported. The aim of this study is to evaluate what effects the parameters of radiosurgery have on the absorbed doses of the lens and thyroid in patients treated by stereotactic radiosurgery, using a systematic plan in a humanoid phantom. Materials and Methods : Six isocenters were selected and radiosurgery was planned using the stereotactic radiosurgery system which the Department of Therapeutic Radiology at Seoul National University College of Medicine developed. The experimental radiosurgery plan consisted of 6 arc planes per one isocenter, 100 degrees for each arc range and an accessory collimator diameter size of 2 cm. After 250 cGy of irradiation from each arc, the doses absorbed at the lens and thyroid were measured by thermoluminescence dosimetry. Results : The lens dose was 0.23$\pm$0.08$\%$ of the maximum dose for each isocenter when the exit beam did not pass through the lens and was 0.76$\pm$0.12$\%$ of the maximum dose for each isocenter when the exit beam passed through the lens. The thyroid dose was 0.18$\pm$0.05$\%$ of the maximum dose for each isocenter when the exit beam did not pass through the thyroid and was 0.41$\pm$0.04$\%$ of the maximum dose for each isocenter when the exit beam Passed through the thyroid. The passing of the exit beam is the most significant factor of organ dose and the absorbed dose by an arc crossing organ decides 80$\%$ of the total dose. The absorbed doses of the lens and thyroid were larger as the isocenter sites and arc planes were closer to each organ. There were no differences in the doses at the surface and 5 mm depth from the surface in the eyelid and thyroid areas. Conclusion : As the isocenter and arc plane were placed closer to the lens and thyroid, the doses increased. Whether the exit beams passed through the lens or thyroid greatly influenced the lens and thyroid dose. The surface dose of the lens and thyroid consistently represent the tissue dose. Even when the exit beam passes through the lens and thyroid, the doses are less than 1$\%$ of the maximum dose and therefore, are too low to evoke late complications, but nevertheless, we should try to minimize the thyroid dose in children, whenever possible.

  • PDF

Effect on Identification of Irradiated Wheat and Soybean by the Full-overlapped Gravitational Field Energy(FGFE) Treatment (중첩중력에너지가 방사선 조사된 밀과 대두의 판별특성에 미치는 영향)

  • Oh, Sang-Lyong;Ahn, Jae-Jun;Kwon, Joong-Ho;Kim, Hak-Je
    • Food Science and Preservation
    • /
    • v.18 no.3
    • /
    • pp.294-301
    • /
    • 2011
  • The aim of this study was to investigate the changes in identification markers of irradiated foods after treatment of the full-overlapped gravitational field energy (FGFE). Wheat and soybean samples were irradiated at 0-5 kGy of Co-60 gamma energy, and analyzed for photostimulated and thermo luminescence characteristics (PSL and TL) and sprouting rate at 0 and 6th month after FGFE treatment. As a screening method for irradiated samples, PSL photon counts (PCs) for the non-irradiated samples appeared negative (<700 PCs), while irradiated samples gave positive (>5,000 PCs). But FGFE-treated irradiated samples appeared intermediate (700-5,000 PCs), showing decreased PCs during storage. The TL analysis on irradiated samples exhibited glow curve peaks in range of $150-200^{\circ}C$ and TL ratio ($TL_1/TL_2$) was also >0.1. Therefore, identification of irradiated samples was possible using thermoluminescence. But the glow curve range of FGFE-treated irradiated samples shifted from $150-200^{\circ}C$ to $180-230^{\circ}C$ and TL intensity was decreased 37-60% resulting from FGFE treatment. After 6 months of storage, all the samples showed a decrease in TL intensity, but identification was still possible. The sprouting rate of irradiated samples decreased by about 72%, whereas that of FGFE-treated irradiated samples showed by about 85%, as compared to non-irradiated samples. More detailed study is required to investigate sprouting phenomena for FGFE-treated samples.