• Title/Summary/Keyword: Ion-Sensing Electrode

Search Result 32, Processing Time 0.03 seconds

Pressure sensing of air flow using multi-walled carbon nanotubes (다중벽 탄소 나노튜브를 이용한 유동 압력 검출)

  • Song, Jin-Won;Lee, Jong-Hong;Lee, Eung-Sug;Han, Chang-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.377-383
    • /
    • 2007
  • We describe the fabrication and characterization of a doubly clamped multi-walled carbon nanotube (MWNT). The device was assembled by an application of electric field in solution. The MWNT was clamped on end of metal trench electrodes in solution and deposited with additional platinum (Pt) on edge of electrode for firmly suspending the MWNT by focused ion beam (FIB). The MWNTs range of diameter and length were 100 to 150 nm and 1.5 to $2{\mu}m$, respectively. Electrical characteristics of fabricated devices were measured by I-V curve and impedance analysis. The mechanical deformation was observed by resistivity in high air pressure. Resonant frequency around 6.8 MHz was detected and resistivity was linearly varied according to the magnitude of air pressure. This device could have potential applications in nanoelectronics and various sensors.

A Study on the Tungstate-Sensing Electrodes (Tungstate Ion 감응 전극에 관한 연구)

  • Gwon-Shik Ihn;Jung-hwa Lee;R. P. Buck
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.2
    • /
    • pp.111-116
    • /
    • 1983
  • Three component $Ag_2S-PbS-PbWO_4$ electrodes have been prepared and evaluated for sensitivity to tungstate. The 51.71 : 16.64 : 31.65(w/w%) composition is superior in terms of potentiometric response, stability, rapidity of response and reproducibility. Testing was done over the concentration range $10^{-1}~10^{-4}M WO_4^{2-}$ in $0.1F-NH_4Ac-NH_4OH$ buffer at pH 8.00 with constant ionic strength. The quality of response is similar to that of corresponding phosphate-sensing electrode. Many common ions interfere.

  • PDF

Preparation of Porous Gold for Sensor Applications (센서 응용을 위한 다공성 골드의 제조)

  • Kim, Young-Hun;Kim, He-Ro;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.32-37
    • /
    • 2008
  • For a development of U-safety system, liquid/gas-sensors that are easy to carry and install in any place are needed. Therefore, in this work, we prepared porous gold using a templating method with nanoporous alumina, and it was used as sensing materials and electrode. The resulting materials showed high purity macroporous structure with $200{\sim}300\;nm$ of window-pore and $4.8\;m^2/g$ of surface area. Because porous gold had good electric conductivity, convenience to measure the change of electric resistivity and good reproducibility, it could be used as potential sensing materials. As a proof-of-concept test, the detection test for mercury ion was carried out.

  • PDF

Method of manufacturing and characteristics of a functional AFM cantilever (기능성 원자간력 현미경 캔틸레버 제조 방법과 특성)

  • Suh Moon Suhk;Lee Churl Seung;Lee Kyoung Il;Shin Jin-Koog
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.56-58
    • /
    • 2005
  • To illustrate an application of the field effect transistor (FET) structure, this study suggests a new cantilever, using atomic force microscopy (AFM), for sensing surface potentials in nanoscale. A combination of the micro-electromechanical system technique for surface and bulk and the complementary metal oxide semiconductor process has been employed to fabricate the cantilever with a silicon-on-insulator (SOI) wafer. After the implantation of a high-ion dose, thermal annealing was used to control the channel length between the source and the drain. The basic principle of this cantilever is similar to the FET without a gate electrode.

  • PDF

Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System (ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링)

  • Han, Hee-Jo;Kim, Hak-Jin;Jung, Dae-Hyun;Cho, Woo-Jae;Cho, Yeong-Yeol;Lee, Gong-In
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.141-152
    • /
    • 2020
  • The rapid on-site measurement of hydroponic nutrients allows for the more efficient use of crop fertilizers. This paper reports on the development of an embedded on-site system consisting of multiple ion-selective electrodes (ISEs) for the real-time measurement of the concentrations of macronutrients in hydroponic solutions. The system included a combination of PVC ISEs for the detection of NO3, K, and Ca ions, a cobalt-electrode for the detection of H2PO4, a double-junction reference electrode, a solution container, and a sampling system consisting of pumps and valves. An Arduino Due board was used to collect data and to control the volume of the sample. Prior to the measurement of each sample, a two-point normalization method was employed to adjust the sensitivity followed by an offset to minimize potential drift that might occur during continuous measurement. The predictive capabilities of the NO3 and K ISEs based on PVC membranes were satisfactory, producing results that were in close agreement with the results of standard analyzers (R2 = 0.99). Though the Ca ISE fabricated with Ca ionophore II underestimated the Ca concentration by an average of 55%, the strong linear relationship (R2 > 0.84) makes it possible for the embedded system to be used in hydroponic NO3, K, and Ca sensing. The cobalt-rod-based phosphate electrodes exhibited a relatively high error of 24.7±9.26% in the phosphate concentration range of 45 to 155 mg/L compared to standard methods due to inconsistent signal readings between replicates, illustrating the need for further research on the signal conditioning of cobalt electrodes to improve their predictive ability in hydroponic P sensing.

Experimental Study on Temperature Dependence of Nitrate Sensing using an ISE-based On-site Water Monitoring System

  • Jung, Dae-Hyun;Kim, Dong-Wook;Cho, Woo Jae;Kim, Hak-Jin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.122-122
    • /
    • 2017
  • Recently, environmental problems have become an area of growing interests. In-situ monitoring of water quality is fundamental to most environmental applications. The accurate measurement of nitrate concentrations is fundamental to understanding biogeochemistry in aquatic ecosystems. Several studies have reported that one of the most feasible methods to measure nitrate concentration is the use of Ion Selective-electrodes (ISEs). The ISE application to water monitoring has several advantages, such as direct measurement methodology, high sensitivity, wide measurement range, low cost, and portability. However, the ISE methods may yield inconsistent results where there was a difference in temperature between the calibration and measurement solutions, which is associated with the temperature dependence of ionic activity coefficients in solution. In this study, to investigate the potential of using the combination of a temperature sensor and nitrate ISEs for minimizing the effect of temperature on real-time nitrate sensing in natural water, a prototype of on-site water monitoring system was built, mainly consisting of a sensor chamber, an array of 3 ISEs, an waterproof temperature sensor, an automatic sampling system, and an arduino MCU board. The analog signals of ISEs were obtained using the second-order Sallen-key filter for performing voltage following, differential amplification, and low pass filtering. The performance test of the developed water nitrate sensing system was conducted in a monitoring station of drinking water located in Jeongseon, Kangwon. A temperature compensation method based on two-point normalization was proposed, which incorporated the determination of temperature coefficient values using regression equations relating solution temperature and electrode signal determined in our previous studies.

  • PDF

An Improvement of Recovery Characteristics of ISFET Glucose Sensor by Employing Oxygen Electrolysis (산소분자의 전기분해법을 도입한 ISFET 포도당센서의 회복특성 개선)

  • Park, Keun-Yong;Choi, Sang-Bok;Lee, Young-Chul;Lee, Min-Ho;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.203-207
    • /
    • 2000
  • The sensitivity of ISFET glucose sensor is improved by employing amperometric actuation method. However, this method takes long time to recover the primary output voltage after measurement because of slow migration of the hydrogen ion between internal and external sensing membranes. Consequently, such a recovery-time delaying problem is one of obstacles to a practical use. In this paper, a new method is proposed to control the concentration of hydrogen ion in internal membrane, which applies a reduction potential to the working electrode for supplying hydroxide ion. Experimental results show that the recovery-time was reduced within 2 minute against decades minute of conventional method.

  • PDF

Thermodynamic Analysis of Solid Electrolyte $CO_2$ Sensor in Continuous and Discontinuous Flow Systems (연속 기체흐름계 및 일시 기체흐름계에서의 고체 전해질 $CO_2$ 가스센서의 열역학적 분석)

  • Choi, Soon-Don
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.319-326
    • /
    • 1998
  • Anodic half-reaction in the $Na^+$ ionic sensors using $Na_2CO_3$ and $MCO_3$ ($M=Cs_2,K_2,Li_2,Ca$) as a sensitive membrane is derived in continuous flow system to explain $CO_2$ sensing characteristics. For various gas-sensitive membranes, a well known overall reaction, $MCO_3\;=\;MO\;+\;CO_2$, cannot be applied for the EMF behaviors of these kinds of sensors. So, the anodic reaction is found to involve $Na_2CO_3$ and $M^{++}$-containing oxide phases by employing the ion exchange reaction at the interface of solid electrolyte and the sensitive membrane to maintain ionic balance in the whole cell. Based on the electrode reaction derived in flow system, differences of cell potentials between continuous and discontinuous flow systems were also discussed. These EMF differences were considerably caused by the partial pressures of oxygen and $CO_2$ as well as irreversible chemical reactions between electrode materials and $CO_2$ atmosphere.

  • PDF

Microfluidic System for the Measurement of Cupric Ion Concentration using Bilayer Lipid Membrane on Silver Surface (은 표면의 이중층 지질막에 의한 구리 이온 농도 측정용 마이크로플루이딕 시스템)

  • Jeong, Beum Seung;Kim, Do Hyun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.1
    • /
    • pp.33-38
    • /
    • 2010
  • A microfluidic system has been developed using biomaterial for the measurement of cupric ion concentration. The cell-membrane-mimicking bilayer lipid membrane(BLM)-coated silver electrode was used for the sensing of cupric ion concentration. The silver-supported BLM could increase its stability. A silver-supported bilayer lipid membrane(s-BLM) was easily obtained using its self-assembling characteristics by immersing silver wire into lipid(phosphatidylcholine; PC) solution and then dipping into aqueous KCl solution. These s-BLMs were used to determine the relationship between $Cu^{2+}$ concentration and current crossing s-BLM. Their relationship showed high linearity and reproducibility. The calibration curve was constructed to express the relationship between $Cu^{2+}$ concentration and current in the $Cu^{2+}$ concentration range of 10 and $130{\mu}M$. This calibration curve was used to measure $Cu^{2+}$ concentration in an unknown sample. Microfluidic system with s-BLM was made of PDMS(polydimethyl siloxane) using typical soft photolithography and molding technique. This integrated system has various functions such as activation of the silver surface without cutting silver wire, coating of BLM on silver surface, injection of KCl buffer solution, injection of $Cu^{2+}$ sample and measurement of $Cu^{2+}$ concentration in the sample.

The Detection of Magnetic Properties in Blood and Nanoparticles using Spin Valve Biosensor (스핀밸브 바이오 센서를 이용한 혈액과 나노입자의 자성특성 검출)

  • Park, Sang-Hyun;Soh, Kwang-Sup;Ahn, Myung-Cheon;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.3
    • /
    • pp.157-162
    • /
    • 2006
  • In this study, a high sensitive giant magnetoresistance-spin valve (GMR-SV) bio-sensing device with high linearity and very low hysteresis was fabricated by photolithography and ion beam deposition sputtering system. Detection of the Fe-hemoglobin inside in a red blood and magnetic nanoparticles using the GMR-SV bio-sensing device was investigated. Here a human's red blood includes hemoglobin, and the nanoparticles are the Co-ferrite magnetic particles coated with a shell of amorphous silica which the average size of the water-soluble bare cobalt nanoparticles was about 9 nm with total size of about 50 nm. When 1 mA sensing current was applied to the current electrode in the patterned active GMR-SV devices with areas of $5x10{\mu}m^2 $ and $2x6{\mu}m^2 $, the output signals of the GMRSV sensor were about 100 mV and 14 mV, respectively. In addition, the maximum sensitivity of the fabricated GMR-SV sensor was about $0.1{\sim}0.8%/Oe$. The magnitude of output voltage signals was obtained from four-probe magnetoresistive measured system, and the picture of real-time motion images was monitored by an optical microscope. Even one drop of human blood and nanopartices in distilled water were found to be enough for detecting and analyzing their signals clearly.