Comparison of Accuracy and Output Waveform of Devices According to Rectification Method (정류방식에 따른 장치의 정확도와 출력 파형의 비교)

  • Lee, In Ja
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

Efficiency Improvement of Uninterruptible Power Supply Systems (무정전 전원장치 효율 향상에 대한 연구)

  • Oh, Heun-Gil;Kwon, Jong-Won;Park, Yong-Man;Odgerel, Odgerel;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.288-290
    • /
    • 2006
  • An efficiency improving method for Uninterruptible Power Supply System(UPS) was developed by using OP-AMP based application circuits such as voltage detection device, current detection device and static switch control device. The efficiency improving algorithm was made by mixing the operating concepts of On-Line type UPS with the operating concepts of Off-Line type UPS. The UPS' inverter does not work if the UPS' output load current is not higher than the low load operating current which is about 0-30(%) of the UPS' output load capacity. The low load operating current is adjustable within the half of the UPS' output load capacity. If the UPS' output load current is rising over than the low load operating current, the UPS' inverter starts working and the inverter output power feeds to the loads of UPS. If UPS' input power breaks out while UPS' inverter does not operate because the load current is low, the inverter starts working within 4(ms) with excessive output voltage which is ${\pm}$8(%) of normal UPS' output voltage. Like these. UPS can continuously feeds power to it's load device and reduce power consumptions.

  • PDF

The Resonant class Φ2 Inverter for short range magnetic resonant wireless power transfer system (근거리 무선전력 전송용 2MHz 공진형 class Φ2 인버터)

  • YANG, Haeyoul;KIM, Changsun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.447-448
    • /
    • 2012
  • With wireless power transfer the of ECR device the designed with a high-frequency and high frequency AC power to the device that may enter the high-frequency switching inverter to be possible. In this paper, is designed to 2MHz switching frequency by using ECR device capable of 2MHz Class ${\Phi}_2$ inverter was designed as a wireless power transmission.

  • PDF

New Layout Design Concept for Suppressing the Substrate Current in CMOS Inverter (CMOS Inverter의 Substrate Current를 줄이는 Layout 설계)

  • Park, Heung-Joon;Kim, Choong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.407-410
    • /
    • 1987
  • A layout design concept which suppress the substrate current generated during the switching transients of an CMOS inverter is presented. The amount of hot carriers and the peak value of substrate current can be reduced by changing the device geometry ratio of driver and load device of an CMOS inverter.

  • PDF

Zero-voltage-switching three level auxiliary resonant commutated pole inverter (영전압 스위칭 3-레벨 보조 공진 폴 인버터)

  • 유동욱;원충연;조정구;백주원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.535-542
    • /
    • 1996
  • A zero voltage switching (ZVS) three level auxiliary resonant commutated pole inverter (ARCPI) is presented for high power GTO inverters. The concept of ARCP for two level inverter is extended to the three inverter. The proposed auxiliary commutation circuit consists of one resonant inductor and two bi-directional switches, which provides ZVS condition to the main devices without increasing device voltage or current stresses. The auxiliary device operates with zero current switching (ZCS) which enables use of the low cost thyristors. The proposed ARCPI can handle higher voltage and higher power (1-10MVA) comparing to the two level one. Operation and analysis of the ARCPI are illustrated and the features are compared o those of the snubber circuit incorporated three level inverter. Experimental results with 10kW, 4kHz prototype are presented to verify the principle of operation. (author). refs., figs., tab.

  • PDF

Study of Internet Web-Based Photovoltaic Inverter Remote Control System (인터넷 웹 기반 환경에서의 태양광용 인버터 원격제어시스템 개발에 관한 고찰)

  • Choi J. Y.;Cho K. S.;Choy I.;Yu G. J.;Jung Y. S.;Kim K. H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.63-66
    • /
    • 2001
  • This paper aims at developing remote control system to control and monitor distributed various devices such as photovoltaic Inverter system through internet. TCP/IP (Transmission Control Protocol/Internet Protocol) and photovoltaic inverter system operated in a row are adopted for network management protocol and applied device, respectively. For controlling and monitoring distributed devices in real-time, java-environment software is constructed. Also, HelloDevice, general-use interface controller between network device and applied device is proposed. Finally, serial communication such as RS-232C is used between controller and applied device.

  • PDF

Development of Internet Web-Based Inverter Remote Control System (인터넷 웹 기반 환경에서의 인버터 원격제어시스템 개발)

  • Choi, J.Y.;Choy, I.;Yu, G.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.219-224
    • /
    • 2002
  • This paper aims at developing remote control system to control and monitor distributed various devices such as UPS or photovoltaic inverter system through internet. TCP/IP(Transmission Control Protocol/Internet Protocol) and photovoltaic inverter system operated in a row are adopted for network management protocol and applied device, respectively. For controlling and monitoring distributed devices in real-time, java-environment software is constructed. Also, HelloDevice, general-use interface controller between network device and applied device is proposed. Finally, serial communication such as RS-232C is used between controller and applied device.

  • PDF

Analysis of Problems when Generating Negative Power for IT devices (IT 기기의 마이너스 전원 생성 시 문제점에 관한 분석)

  • Jun, Ho-Ik;Lee, Hyun-Chang
    • Journal of Software Assessment and Valuation
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2020
  • In this paper, the problem that occurs when negative voltage is generated using an inexpensive buck device in an IT device that is supplied with a single power by an adapter or battery is analyzed. For the cause analysis, the principle of operation of the buck device and the principle of the inverter circuit were examined, and the circuit characteristics of the inverter circuit were analyzed using the buck device. As a result of the analysis, it was confirmed that the inverter circuit using the buck device initially needs a large starting current, and in particular, in the case of a current capacity that is less than the starting current in the circuit that supplies power, it was confirmed that it could fall into a state similar to the latch-up phenomenon. In order to confirm the analysis result, an experimental circuit was constructed and the input current was checked. If the supply current is sufficient, it is confirmed that over-current flows and starts. If the supply current is insufficient, the circuit cannot start and a latch-up phenomenon occurs.

Simulation and Analysis of Losses of Switching Device for Single Grid-connected Full Bridge Inverter (단상 계통 연계형 풀브릿지 인버터의 스위치 손실 모의 및 분석)

  • Son, Myeongsu;Lim, Hyun-Ji;Cho, Younghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.4
    • /
    • pp.294-297
    • /
    • 2018
  • This paper analyzes the losses of the switching device for a full bridge inverter connected to the grid. As the development of power conversion system, losses are dominant factors in judging the efficiency of a system. The losses of a switching device can be divided into switching loss and conduction loss, both of which can be estimated by analyzing periodic switching waveform. The switching loss is generated when the switch is turned on and off, while the conduction loss is generated when the switch is turned on. The estimated losses of the MOSFET switch are compared with the simulation results.

Performance of an inverter refrigeration system with a change of expansion devices (인버터형 냉동시스템의 팽창장치 변경에 따른 성능특성)

  • 이용택;김용찬;박윤철;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.928-936
    • /
    • 1999
  • An experimental study was performed to investigate characteristics of an inverter driven water-to-water refrigeration system with a variation of compressor frequencies and expansion devices. The frequency of a compressor varied from 30Hz to 75Hz, and performance of the systems applying three different expansion devices such as capillary tube, thermostatic expansion valve(TXV), and electronic expansion valve(EEV) were measured. The load conditions were altered by varying the temperature of the secondary fluid entering condenser and evaporator with a constant flow rate. When the test conditions were deviated from the standard value(rated value), TXV and EEV showed better performance than capillary tube due to optimum control of mass flow rate and superheat. In the present study, it was observed that the variable area expansion device had better performance than constant area expansion device in an inverter refrigeration system due to active control of flow area with a change of compressor frequency and load conditions.

  • PDF