• 제목/요약/키워드: Inverter Filter

검색결과 529건 처리시간 0.021초

DVR시스템에 사용되는 인버터부의 LC필터 설계와 피드백 성능분석 (Design and Feedback Performance Analysis of the Inverter-side LC Filters Used in the DVR System)

  • 박종찬;손진근
    • 전기학회논문지P
    • /
    • 제64권2호
    • /
    • pp.79-84
    • /
    • 2015
  • Voltage sags are considered the dominant disturbances affecting power quality. Dynamic voltage restorers(DVRs) are mainly used to protect sensitive loads from the electrical network voltage disturbances such as sags or swells and could be used to reduce harmonic distortion of ac voltages. The typical DVR topology essentially contains a PWM inverter with LC Filter, an injection transformer connected between the ac voltage line and the sensitive load, and a DC energy storage device. For injecting series voltage, the PWM inverter is used and the passive filter consist of inductor(L) and capacitor(C) for harmonics elimination of the inverter. However there are voltage pulsation responses by the characteristic of the LC passive filter that eliminate the harmonics of the PWM output waveform of the inverter. Therefore, this paper presented design and feedback performance of LC filter used in the DVRs. The voltage control by LC filter should be connected in the line side since this feedback method allows a relatively faster dynamic response, enabling the elimination of voltage notches or spikes in the beginning and in the end of sags and strong load voltage THD reduction. Illustrative examples are also included.

전압형 인버터의 출력전압 상승률 억제를 위한 출력 필터의 설계 (Output Filter Design for Suppression of High Voltage Gradient in the Voltage-Fed PWM Inverter)

  • 김성준;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.296-298
    • /
    • 1995
  • This paper proposes a new filter topology that suppresses the high voltage gradient(dv/dt) in ac motor terminals. The high voltage gradient(dv/dt) causes over voltages on the motor windings, the degradation or motor insulation, and the bearing failure. Moreover surge voltage with high voltage gradient(dv/dt) in the PWM inverter red drive system where long line cables are required causes more serious problem to the motor. Thus, the most advisable method is attaching output filter to the inverter output terminals. The conventional output filters have several problems such as bulky size, difficulty or parameter tuning. The proposed filter can be relatively smaller than the conventional filters. By the proposed filter, the shaping or PWM waveform can considerably suppress high dv/dt in motor feeding cable from the inverter. The effectiveness or the proposed filter is compared with that or the conventional one and is verified by the computer simulation.

  • PDF

직류송전 인버터의 필터 최적설계를 위한 해석 및 목적함수의 선정 (Analysis of HVDC Inverter and Application of Objective Functions for the Optimal Filter Design)

  • 오성철;정교범
    • 전력전자학회논문지
    • /
    • 제6권1호
    • /
    • pp.82-89
    • /
    • 2001
  • 본 논문은, HVDC 시스템의 인버터 제어기 및 고조파 필터의 설계를 위하여 동특성 및 정상상태 특성을 해석하는 방법을 제시한다. EMTP 시뮬레이션을 이용하면, 동특성 분석이 가능하며, 정상상태 특성의 분석은필터와 부하를 고려한 조류해석을 수행함으로써 가능하다. 또한 본 논문은 HVOC 시스템의 정적 및 동적 특성 분석이 가능한 단상 등가회로를 제안한다. 이 단상 등가회로에서 인버터는 스위치의 소호에 따른 전류원으로 취급된다. 또한 필터설계에 사용되고 있는 각종 목적함수를 단상 등가회로룹 이용하여 구할 수 있다, 본 논문은 전압의 고조파 성분 및 필터의 전력손실을 고려한 목적함수를 이용하여 펄터를 최적화하는 과정이 제시되어 있다.

  • PDF

A Novel Filter Design for Output LC Filters of PWM Inverters

  • Kim, Hyo-Sung;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • 제11권1호
    • /
    • pp.74-81
    • /
    • 2011
  • The cutoff frequency of the output LC filters of PWM inverters limits the control bandwidth of the converter system while it attenuates voltage ripples that are caused by inverter switching activities. For a selected cutoff frequency of an output LC filter, an infinite number of L-C combinations is possible. This paper analyses the characteristics of output LC filters for PWM inverters terms of the L-C combinations. Practical circuit conditions such as no-loads, full resistive-loads, and inductive-load conditions are considered in the analysis. This paper proposes a LC filter design method for PWM inverters considering both the voltage ynamics and he inverter stack size. An experimental PWM inverter system based on the proposed output LC lter design uideline is built and tested.

임피던스 정합을 이용한 능동 인버터 대역 통과 여파기 (Active Inverter Bandpass Filter using Impedance Matching)

  • 이호준;박현창;박형무;이진구
    • 한국전자파학회논문지
    • /
    • 제13권3호
    • /
    • pp.237-242
    • /
    • 2002
  • 본 논문에서는 임피던스 정한 방법을 이용하여 IMT-2000 주파수 대역인 2.155 GHz 대역에 사용할 수 있는 능통 여파기를 설계 및 제작하였다. 임피던스 정합과 공진기를 구현하기 위하여 아미크로스트립 랑니을 이용하였다. 능동 여파기의 측정결과 중심주과수 2.18 GHz에서 대역폭 75 MHz, 삽입 이득 14.1 ㏈, 중심주파수를 기준으로 $\pm$200 MHz 떨어진 지점에서 23㏈의 가쇄 특성을 보였다.

LCL 필터를 사용하는 계통 연계형 인버터의 넓은 안정 영역을 갖는 새로운 제어 및 설계 기법 (Novel Control and Design Method for Wide Stability Range of Grid Connected Inverter with LCL Filter)

  • 박권식;서병준;김학수;노의철
    • 전력전자학회논문지
    • /
    • 제23권6호
    • /
    • pp.440-445
    • /
    • 2018
  • This study proposes a novel control and design method for a grid-connected inverter with an LCL filter without damping. The current resonance phenomenon must be considered when designing the grid-connected inverter system with an LCL filter. Passive or active damping is used in the inverter system to reduce the resonant current. However, passive damping reduces the efficiency of the system, and active damping methods are complex. If the resonant frequency is in a specific region, then the system will be unstable. This study examines the process of stabilizing the entire region without resonant damping. The validity of the proposed method is verified through simulation and experimentation.

멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동 전력필터 (A Hybrid Active Power Filter for Electric-Railway Systems Using Multi-Level Inverters)

  • 김윤호;김수홍;이강희
    • 한국철도학회논문집
    • /
    • 제7권4호
    • /
    • pp.339-344
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 3rd harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.

A Novel Active Damping Control of a Three-phase PWM Inverter with LC Filter

  • Kim, Kwang-Seob;Hyun, Dong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1589-1596
    • /
    • 2015
  • A novel control method of a three-phase PWM inverter with LC filter is proposed. The transfer function of LC filter is the same as that of 2nd order low pass filter(2nd LPF) which has a zero damping ratio. A simple method of implementing 2nd LPF with damping ratio is to add resistor to inductor or capacitor of LC filter. In an industrial application, it is not practical to adopt damping resistor because it results in losses being proportional to square of current flowing through resistor. Instead of using damping resistors, the proposed active damping control(ADC) utilizes all pass filter(APF) and considers inherent processing delay of digital controller. The overall transfer function of the proposed method is the same as a 2nd LPF and its damping ratio is also controllable via control variables. Detailed design and implementation of controller is also presented. Experiments are conducted with a 7.5kVA induction motor drive system controlled by PWM converter and inverter. Test waveforms are also presented to verify the proposed LC filter control algorithm.

PWM 인버터 시스템에서의 전도노이즈 저감을 위한 출력필터 설계에 관한 연구 (Output Filter Design for Conducted EMI Reduction of PWM Inverter-Fed AC Motor Drive System)

  • 김이훈;박규현;원충연;김영석;최세완
    • 전력전자학회논문지
    • /
    • 제6권6호
    • /
    • pp.546-555
    • /
    • 2001
  • 본 논문에서는 PWM 인버터-유도전동기 구동시스템의 전도노이즈 저감을 위한 출력필터 설계에 관한 연구를 수행하였다. 전도노이즈는 고전압 입력, 고용량 구동시스템 그리고 긴 전동기 터미널 등의경우에서 크게 문제가 된다. 고압력을 갖는 시스템에서는 높은 압력에 비례한 직류 링크 전압을 갖고 이에 따라 스위칭 dv/dt가 순간 최대 CM 접지전류를 발생시킨다. 그러므로 이에 대한 대책이 필요하다. 따라서 최근 산업 현장에서 많이 사용되고 있는 PWM 인버터를 설계 제작하여 유도전동기를 구동하고 이에 따라 발생되는 전도노이즈 성분을 감쇠 시킬 수 있는 출력필터를 설계하였고 제작 및 실험을 통하여 그 타당성을 입증하였다.

  • PDF

계통연계 인버터의 인덕터 최적화 기법을 통한 LCL 필터 설계 (Design of LCL Filter through Inductor Optimization Method in Grid-Connected Inverter)

  • 장재하;김경화
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.58-67
    • /
    • 2014
  • A grid-connected inverter used for renewable energy resources produces harmonic components in the switching frequency. To effectively reduce switching harmonic components, several types of filter are generally used in the output stage of the grid-connected inverter. Many research works on LCL filter design have been done to maintain the performance with low cost. However, it is not easy to make the filter design be economical and optimal due to the varying characteristic of magnetic core and redundancy design by experience. In this paper, a design method for a LCL filter is presented through the inductor optimization scheme in view of the size and cost when the inductor is manufactured using the magnetic core. The effectiveness is verified through tests using a 3kW grid-connected inverter by simulations and experiments.